PROCEDURE
1) A standard was prepared in solvent and was placed into sample holder for the purpose of calibration curve.
2) The liquid sample was also prepared in a similar manner and placed into sample holder.
3) The UVProbe Software was opened and the method(M) was set to wavelength of 800-0.0 at medium speed for measuring liquid sample absorbance , and the method was saved in a file according to sample name.
4) The standard for baseline measurement was run. (The first run using an empty cuvette followed by the standard sample)
5) Sample measurement was continued.
6) All the results were saved and the spectrum produced was saved.
7) The main component in UV-VIS unit along with the diagram of the unit was drawn.
8) Spectrum obtained was analyzed based on wavelength peak and compared against calibration curve.
9) The analyte concentration found in the unknown was determined.
10) All the findings were summarized based on the spectrum obtained and related information derived from the experimental work and from references.
STANDARD OPERATING PROCEDURE FOR UV-VIS UNIT
Start-Up
A. Equipment
1. The power supply was connected to the unit.
2. The unit and PC was switched on.

B. Steps to Perform Analysis
1. The UVPorbe Software was opened and CONNECT button was clicked. A series of tests is automatically conducted which may take about 5 minutes. All checklist is made sure to be green.
2. Prior to analysis , the method was set according to requirement, by clicking the M button.
3. The method was then saved based on sample name and the FILE menu was clicked. The method is then saved as on a created new folder.
4. Calibration must be done using BaSO4 for solid sample or solvent for liquid (50%ethanol and 50% DI water / 70% ethanol and 30% in DI water) containing the analyte (five concentration of analyte plus bank i.e without sample) as standard calibration.
5. The BaSO4 for solid or solvent for liquid cell was placed at sample holder. The BASELINE icon

You May Also Find These Documents Helpful

  • Good Essays

    Read the Introductory information and the Procedure located in the window to the left of the screen and then perform the laboratory. For your convenience, the data table has been inserted below – fill this one in (the website tends to delete data):…

    • 669 Words
    • 3 Pages
    Good Essays
  • Good Essays

    The purpose of this experiment was to determine the concentration of an unknown amount of copper sulfate using the spectronic 20. Four solutions of different concentrations of H₂O and CuSO₄ were put into the spectronic 20 to observe their absorption of light. Then, a graph was created to plot down the measurements. Using the calibration curve of the graph, the concentration of the unknown substance was found out to be .12M.…

    • 476 Words
    • 2 Pages
    Good Essays
  • Satisfactory Essays

    Organic Chemistry Ir Lab

    • 511 Words
    • 3 Pages

    Initially the plates were rinsed with ethanol, then dried with lint0free tissues. Next 1-2 g of benzoic acid were transferred to a mortar and a pestle was then use to grind the sample. About 100-150 mg of oven dried potassium bromide were added into the mortar and mixed well and then grinded. Next a screw was attached to a bolt and tightened together to make a sample holder. Next another screw was attached to the bolt to fasten it. The sample holder was then mounted onto the sample holder support on the table bench and a wrench was used to tighten the screw. It was held there for about 1-2 minutes and the bolts were loosened and removed. It was made sure not to fasten the bolts too tight or it would damage the bolt and the screw sample holder. After removing the two screws and transparent solid sample pellet ready to be measured was found formed within the screw.…

    • 511 Words
    • 3 Pages
    Satisfactory Essays
  • Powerful Essays

    Cyclic Voltammetry

    • 4350 Words
    • 31 Pages

    in drug samples electrochemically. SWV was used to plot the calibration curve and there was a good linear relationship between…

    • 4350 Words
    • 31 Pages
    Powerful Essays
  • Powerful Essays

    10g of Sodium bromide, 6g of butan-1-ol and 10cm3 of water was placed in a 50cm3 round bottom flask.…

    • 962 Words
    • 4 Pages
    Powerful Essays
  • Better Essays

    For the second part of the experiment, a glass burette was marked and filled to 0 mL.…

    • 814 Words
    • 5 Pages
    Better Essays
  • Good Essays

    75 µL Calibrator and Sample X was pipettes into appropriate labeled tubes. The blank tube was leaved without add any sample.…

    • 568 Words
    • 3 Pages
    Good Essays
  • Good Essays

    Apparatus/Materials: Cyclohexane, liquid alkane, aqueous bromine, test tubes, light source, watch glass, splint, 0.1 MKMnO4, concentrated H2SO4, dilute H2SO4.…

    • 3543 Words
    • 15 Pages
    Good Essays
  • Good Essays

    (1) Wavelength selection (2) Printer button (3) Concentration factor adjustment (4) UV mode selector (Deuterium lamp) (5) Readout (6) Sample compartment (7) Zero control (100% T) (8) Sensitivity switch (9)ON/OFF switch…

    • 467 Words
    • 2 Pages
    Good Essays
  • Satisfactory Essays

    Chemistry Notes

    • 292 Words
    • 2 Pages

    * A number of Solutions (of known concentrations) containing the substance to be tested are prepared.…

    • 292 Words
    • 2 Pages
    Satisfactory Essays
  • Powerful Essays

    Initially, a stock solution of 1 mg/ml was dissolved and used to prepare desired dilutions with LC grade milli-Q water. Prepare 10 ml each of 1000.0, 1200.0, 1500.0, 2500.0, 5000.0, 9000.0, 18000.0 and 20000.0 ng/ml of Barnidipine standard solutions using the Barnidipine standard stock solution and mobile phase and store at –20 ± 2ºC until analysis. Prepare 10.0 ml each of 50.0, 60.0, 75.0 ,125.0, 250.0, 450.0, 900.0 ,1000.0 ng/ml of Barnidipine Calibration curve samples using 0.5 ml of Barnidipine standard stock solution and make up the volume with blank plasma, transfer in to different 2 ml centrifuge tubes and store at –70 ± 2ºC until…

    • 890 Words
    • 4 Pages
    Powerful Essays
  • Better Essays

    obeyed in the concentration range of 5-25 µg/ml. The method was validated in terms of linearity, precision…

    • 1278 Words
    • 6 Pages
    Better Essays
  • Better Essays

    calibration

    • 1271 Words
    • 6 Pages

    Calibration is the process by which a stated measure such as the volume of a container is checked for accuracy. In general, measurements of mass can be determined more precisely and accurately than measurements of volume. Therefore, the mass of the liquid contained or dispensed by the glassware will be measured and the corresponding volume calculated using the density of the liquid. However, a relatively small change in temperature causes a change in the liquid’s volume and thus its density.…

    • 1271 Words
    • 6 Pages
    Better Essays
  • Powerful Essays

    Instrumentation Lab

    • 1511 Words
    • 7 Pages

    Although the exact procedure may vary from product to product, the calibration process generally involves using the instrument to test samples of one or more known values called “calibrators…

    • 1511 Words
    • 7 Pages
    Powerful Essays
  • Better Essays

    Analytical chemistry involves the separation, identification and determination of amounts of components in a particular sample. Accuracy and precision are important in data acquisition to be able to acquire substantial results in the end of the experiment. To attain such goal, replication of measurements must be performed. The reliability of the measurements may then be evaluated through various statistical parameters [1].…

    • 1668 Words
    • 7 Pages
    Better Essays