Estimation of Total Bilirubin and Direct Bilirubin.
Title : Estimation of Total Bilirubin and Direct Bilirubin.
Aim : To determine the concentration of Total Bilirubin, Direct Bilirubin and Indirect Bilirubin in sample X.
Principle :
Procedure (A) : Estimation of Total Bilirubin.
Total bilirubin, both conjugated and free, are measured by using a stabilized diazonium salt of 3, 5-dichloroaniline which reacts with bilirubin to form azobilirubin with maximum absorbance at 540nm.
Procedure (B) : Estimation of Direct Bilirubin.
This methods are based on the reaction between direct (conjugated) bilirubin and diazotized sulphanilic acid solutions. Direct Bilirubin reagent utilizes an acid diazo method. Conjugated bilirubin will reacts with diazotized sulphanilic acid to produce an acid azobilirubin, the absorbance of which is proportional to the concentration of direct bilirubin in the sample and can be measured at 550nm.

Materials :
1. Total bilirubin reagent.
2. Direct bilirubin reagent.
3. Calibrator.
4. Sample X.
5. Appropriate number of tube(s) for:
a. Blank
b. Calibrator
c. Sample X
6. Cuvettes.
7. Spectrophotometer.

Methods :
Procedure (A) : Estimation of Total bilirubin.
1. All the tubes was labeled accordingly to blank, calibrator and sample X.
2. 1500 µL of Total bilirubin was pipettes into each tubes.
3. All tubes was incubated at 37oC for 5 minutes.
4. 75 µL Calibrator and Sample X was pipettes into appropriate labeled tubes. The blank tube was leaved without add any sample.
5. All tubes was incubated at 37oC for 5 minutes.
6. The reading of Absorbance of blank tube in a spectrophotometer at 540 nm wavelength was recorded. This was the Blank Absorbance. ‘0 ABS/100%T’ was pressed to set blank.
7. The reading of Absorbance for Calibrator and Sample X in spectrophotometer at 540 nm wavelength was pointed. These absorbance are the Reaction Absorbance for each tube.

Procedure (A) : Estimation of Direct bilirubin.
1. All the tubes was labeled accordingly to blank, calibrator and

You May Also Find These Documents Helpful

  • Powerful Essays

    Penny Lab Report

    • 2257 Words
    • 10 Pages

    Introduction: In the spectrophotometric analysis of a penny lab, we will be conducting three experiments. The purpose of the first experiment is to find the maximum absorbance on the spectrometer to obtain the optimum wavelength. Once we have gathered that information, we will use the results in the other two experiments. The purpose of…

    • 2257 Words
    • 10 Pages
    Powerful Essays
  • Powerful Essays

    min . The calibration curve was linear over the range 0.1-5.0μg/ml. The method was also suitable for the…

    • 3534 Words
    • 26 Pages
    Powerful Essays
  • Good Essays

    In order to complete the objective, the group used a Carolina Digital Spectrophotometer, unit M 201-1, which measures the quantity of light that solutions absorb. The spectrophotometer consists of a light source that shines through a prism which then shines through a…

    • 1159 Words
    • 5 Pages
    Good Essays
  • Good Essays

    Spinach Lab

    • 767 Words
    • 4 Pages

    To prepare the solution, 4 mL of 80% acetone was pipetted into a test tube, and five drops of the top layer of the pigment extract from the first experiment was combined with the acetone. The test tube was inverted until thoroughly mixed. Then a test tube containing 4 mL of 80% acetone was created to blank the spectrophotometer at 380 nm. The absorbance of the tube with the extract and acetone solution was then tested for its absorbency. These tests were repeated with the same solution at 40 nm intervals, until the wavelength reached 740 nm, re-blanking the machine between each test or change in wavelength. All the absorbencies were recorded, and the areas with the highest absorbance were retested at 5 nm intervals. The results were then plotted on Excel to show the relationship between certain wavelengths and the absorbance of the…

    • 767 Words
    • 4 Pages
    Good Essays
  • Better Essays

    Copper In Brass Lab

    • 1053 Words
    • 5 Pages

    One test tube was then filled half full with the same solution of nitric acid and wiped clean of finger prints and smudges. This sample was used as a blank to set the zero absorbance for the spectrophotometer. The direction of the test tube was marked and noted for future use. The student then selected a New Absorbance vs. Concentration experiment in SpectroPro. This was done in order to calibrate the spectrophotometer. The wavelength setting was set on the spectrophotometer at 620nm and the machine was set absorbance, listed as unit (A). The student set the blank to zero absorbance and finished the calibration of the spectrophotometer. The solution in the test tube was then discarded and the test tube was set…

    • 1053 Words
    • 5 Pages
    Better Essays
  • Satisfactory Essays

    Cyclohexane Lab Report

    • 175 Words
    • 1 Page

    The samples were recorded using a UV-Vis spectrometer. In addition, the absorbance of the first sample was…

    • 175 Words
    • 1 Page
    Satisfactory Essays
  • Good Essays

    Lab 2 Bio 100

    • 525 Words
    • 3 Pages

    List whether each of the following substances was positive or negative for protein, as indicated by the Biuret test. (7 points)…

    • 525 Words
    • 3 Pages
    Good Essays
  • Good Essays

    lab reports

    • 934 Words
    • 5 Pages

    3) The absorbance of a 0.0816 M solution of a molecule is measured using a 1.000 cm pathlength cuvette. Two peaks are observed in the spectrum, one at  = 317 nm (A = 0.1286), the other at  = 284 nm (A = 0.7215). Assuming Beer’s law holds…

    • 934 Words
    • 5 Pages
    Good Essays
  • Satisfactory Essays

    Experiment 2

    • 532 Words
    • 3 Pages

    Figure 1. Sample calibration curve of standard Fluorescence solutions, average absorbance against concentration of standards. The concentration range of standard used was from 4.984x10-9 to 49.84ppm. The best fit line was determined by Regression analysis in Microsoft® Excel. The equation of best fit was y=0.1255 x +0.3353, the slope was 0.1255 V/ppm and the y intercept was 0.3353 V. The R2 value was 0.965.…

    • 532 Words
    • 3 Pages
    Satisfactory Essays
  • Good Essays

    In this lab we employed various assays utilizing a biuret reagent, coomassie brilliant blue reagent, and ultraviolet light in order to determine the identity of six unknown solutions and the concentration of a bovine serum albumin sample. We were given three samples that lacked protein, and three samples containing proteins, and using a spectrophotometer we assessed the amount of light absorbed versus the light transmitted, based on the principles of the Beer-Lambert Law. The three proteins used included lysozyme, protamine sulfate, and bovine serum albumin, and the three non-protein samples contained either RNA, tyrosine, and glycylglycylglycine. Standard curves were created to exhibit the linear relationship between the concentration of solute (protein, non-protein) and the resulting absorbance.…

    • 902 Words
    • 4 Pages
    Good Essays
  • Good Essays

    Lab Report

    • 434 Words
    • 2 Pages

    Using the China marker, I numbered test tubes 1-5 for identification purposes. Using a pipet I added 1 milliliter of each solution to it’s designated test tube. Next, I added 5 drops of the Biuret reagent to each test tube and agitated the mixture by shaking the tubes from side to side. After waiting 2 minutes I recorded the color of each mixture. I used the color reaction after adding the reagent to determine the presence of proteins in each substance (Mbuthia, 2012).…

    • 434 Words
    • 2 Pages
    Good Essays
  • Good Essays

    jlias sudbioa

    • 553 Words
    • 3 Pages

    Take 1 mL samples at given time points & add to tubes containing 2 mL of 0.05 M NaOH…

    • 553 Words
    • 3 Pages
    Good Essays
  • Powerful Essays

    Molarity Lab Report

    • 1392 Words
    • 6 Pages

    The wavelength was set to absorbance of 600 nm, which is the max for Cu2+. Ten small test tubes were cleaned and a piece of label tape was placed around the top of each tube. A vertical straight line was drawn on the tape to help align with the mark on the instrument sample holder. The transmittance of the Spec 20 was set to 0% using the left-hand adjustment knob while the well was empty and closed. One test tube was filled 3/4 full of a blank solution (distilled water). A Kimwipe was used to wipe off any solution on the outside of the test tube. The test tube was then placed into the empty well with both the mark on the test tube and the mark on the well aligned. The lid of the well was closed. The right-hand adjustment knob was used for setting the transmittance to…

    • 1392 Words
    • 6 Pages
    Powerful Essays
  • Best Essays

    Spectroscopy is the study of light. A spectrophotometer is a machine used to determine the absorbance of light at any given wavelength. It does this by using a source of white light through a prism, which gives multiple wavelengths that can be individually focused (Ayyagari and Nigam, 2007). Substances are put into cuvettes that are glass or quartz containers that light can easily travel through. The light that is being focused travels through the substance gets absorbed by the substance and is reflected back and read by galvanometer which had the ability to detect electric currents (Verma, R). The absorbance reading is then given, absorbance is usually between 0.0 – 2.0, any higher than 2.0 may mean not enough light is getting through to the galvanometer (Bhowmik and Bose, 2011). When using the spectrophotometer it is necessary to use a control or blank to zero or tare the machine in between every new wavelength or concentration, this control is water (Ayyagari and Nigam, 2007). The correlation between the numbers acquired through spectroscopy can be seen using the Beer- Lambert Law. The Beer- Lambert law states that the amount of light absorbed at a certain wavelength is proportional to the concentration of the absorbing substance (Fankhauser, 2007).…

    • 2210 Words
    • 9 Pages
    Best Essays
  • Best Essays

    The UV/Vis spectrophotometer work by passing the light by strong lamp through a monochromator, which split the light into its component colours using a gratings. Then, the desired wavelength of light beam is direct through the sample compartment which the cuvette is placed by using the mirror and slit. At other side of the compartment, there is a detector which can determine the amount of light beam pass through the solution in the cuvette, thus the absorbance of the solution in the cuvette can be determined. In addition, the absorbance of light is determined by three factors which is the nature of the solution, concentration of the solution, and the distance of light travel through the solution (path length) which stated in the Beer-Lambert Law.…

    • 2163 Words
    • 9 Pages
    Best Essays

Related Topics