Preview

Flow Meter Measurement Latest Full Report

Powerful Essays
Open Document
Open Document
1508 Words
Grammar
Grammar
Plagiarism
Plagiarism
Writing
Writing
Score
Score
Flow Meter Measurement Latest Full Report
THERMAL-FLUID
ENGINEERING’S
FULL LAB REPORT
I hereby declare that this report is written by me/us and it is my own/group effort and no part has been plagiarized without citations

FACULTY OF MANUFACTURING ENGINEERING
EXPERIMENT TITLE: MEASUREMENT WITH FLOWMETER

GROUP NO: 02

SECTION: 02

NAME OF STUDENT

NO ID

1. ALI ZULFAKAR BIN KHAIRUDIN

FA12032

2. MOHD ZUL ASRI BIN MOHD RAMLI

FB12011

3. MUHAMAD ASLAM BIN ABDUL RAUB

FB12010

PRACTICAL DATE: 20 MARCH 2015

WEEK:04

SUBMISSION DATE (FULL REPORT): 27 MARCH 2015

WEEK:05

LECTURER NAME: SURAYA SULAIMAN
REMARKS:
Thermal-Fluid Engineering Lab (BFF3801) SEM 2 2014/2015 (Front Page) © SurayaSulaiman

THERMAL-FLUID ENGINEERING’S
LAB RUBRIC
(FULL LAB REPORT)

No

Criteria Details

Scoring Criteria

Marks

1.0

Objectives

Objectives clear

2.0

Theory

Theory clear

3.0

Experiment
Apparatus
Procedure

All experiment apparatus are listed and pictures are labeled. Procedures are listed clearly and in order.

5.0

Experiment
Results

20

6.0
7.0

Sample of
Calculations
Discussions

All numerical data reported. The results are correct and labeled appropriately. Graphs are labeled and titled and tables are complete.
Show clearly the sample of calculation of result findings.

25

8.0

Conclusions

9.0

Application in
Industry
References/
Appendices
Format

Complete discussion and evaluation of the results.
Information is synthesized, arguments made to address the questions. Conclusions meets the objectives and effectively communicate purpose and synthesize information from experiment Relate the experiments with the application that applied in industry Clearly stated the references.
Follow the guidelines, typed, organized, and fewer error in spelling, punctuation and grammar.

10

4.0

10.0
11.0
12.0

Score

5

5

10

10

10
5

Total

/100

Experiment #D. Measurement with Flowmeter

1.0:Objectives

To design and conduct one experiment to measure the different flow measurement using venturi, orifice, rotameter and bench.



References: Appendices   Wikipedia Fluid Mechanics (SI units): Fundamentals and Applications by Yunus A. Cengel (Author), John M. Cimbala (Author)

You May Also Find These Documents Helpful

  • Better Essays

    3. Liu, Hongtan. Heat Exchangers: Selection, Rating, and Thermal Design. 2nd ed. Boca Raton: CRC, 2000. Print.…

    • 1284 Words
    • 9 Pages
    Better Essays
  • Powerful Essays

    Diffusion of Innovation

    • 1914 Words
    • 8 Pages

    Hitchcock, S. (2010, December 21). Columbia omni-heat technology review [Online forum comment]. Retrieved from http://www.upadowna.org/gear/review/columbia-omni-heat-technology…

    • 1914 Words
    • 8 Pages
    Powerful Essays
  • Good Essays

    Cmi 5001

    • 1132 Words
    • 5 Pages

    By submitting this assignment for assessment, I am also confirming that the following report is the result of my own study and efforts. I understand that if this not the case, I will be putting at risk the successful completion of this qualification.…

    • 1132 Words
    • 5 Pages
    Good Essays
  • Good Essays

    OBJECTIVES To study the characteristics and applications of various flow measuring device (venturi meter & orifice plate). To calculate the volume flow rate of water from the pressure difference of both venturi and orifice devices. To compare between theoretical and actual volumetric flow rate through the discharge coefficient concept. To know how rotameter works.…

    • 1454 Words
    • 6 Pages
    Good Essays
  • Best Essays

    The purpose of this experiment is to investigate the flow rate/discharge and the head loss of 3 particular flow measuring apparatus which are the Venturi Meter, Orifice Meter and Rota Meter in accordance to Bernoulli’s Equation. The time taken for the water to discharge as the diameter of Rota Meter increased was determined and tabulated. Then, the discharge & head loss for each apparatus is calculated using the data obtained through the experiment and the calculations were tabulated. The results were analyzed and its accordance to Bernoulli’s Equation was discussed. The experiment was completed and carried out successfully.…

    • 1496 Words
    • 6 Pages
    Best Essays
  • Powerful Essays

    Flow Measuring Apparatus

    • 1701 Words
    • 7 Pages

    Flow of incompressible fluids (example: water) can be determine by using several type of methods with using the flow measuring apparatus. This experiment is to demonstrate the characteristics of several different commonly used methods of measuring fluid flow rates. This experiment also needs to determine the head losses associated with each flow measuring methods (venture…

    • 1701 Words
    • 7 Pages
    Powerful Essays
  • Satisfactory Essays

    FLOW MEASUREMENT

    • 677 Words
    • 3 Pages

    EXPERIMENT (4) FLOW MEASUREMENT By: Eng. Motasem M. Abushaban. Eng. Fedaa M. Fayyad.…

    • 677 Words
    • 3 Pages
    Satisfactory Essays
  • Powerful Essays

    flow measurement report

    • 5169 Words
    • 35 Pages

    The object of this experiment is to study the performance of an orifice plate flow measurement…

    • 5169 Words
    • 35 Pages
    Powerful Essays
  • Powerful Essays

    Body of the report (this section is further divided into as many sections as necessary)…

    • 2899 Words
    • 12 Pages
    Powerful Essays
  • Good Essays

    Water enters and first flows through the Venturi metre, then through the Orifice plate and then through the Rotor meter. On leaving the Rotor meter the water flows via a control valve to the weigh-tank of the hydraulic bench. At the inlet and the outlet of each flow measuring device is a connection to the manometer board, this allows the head loss to be determined across each device.…

    • 1800 Words
    • 8 Pages
    Good Essays
  • Powerful Essays

    Flow Meters

    • 2678 Words
    • 11 Pages

    There are well over 20 different types of flow meters, even if we lump the various positive-displacement flow meters together as one type. Unless the process engineer knows the pros and cons of each type, it can be a daunting task to properly select one. Here are just some of the factors to consider before selecting a flow meter:…

    • 2678 Words
    • 11 Pages
    Powerful Essays
  • Better Essays

    Engineering

    • 2354 Words
    • 10 Pages

    1- From Wikipedia Shell and tube heat exchanger, Perry, Robert H. and Green, Don W. (1984). Perry 's Chemical Engineers ' Handbook, 6th Edition, McGraw-Hill.…

    • 2354 Words
    • 10 Pages
    Better Essays
  • Good Essays

    The objective of this experiment to investigate the use of extended surface to improve heat transfer through surfaces. In addition, another target is to demonstrate the effect of the fluid speed on the heat transfer by convection.…

    • 615 Words
    • 3 Pages
    Good Essays
  • Good Essays

    This is an experiment about procedures of calibration of a Coriolis mass flow meter. To do the experiment, water is pumped from a reservoir and its flow rate is set by a tap, the height drop is examined by eye and the time is recorded for a period during the flow. This procedure is arranged for the calibration of the Coriolis meter by comparing the calculated mass flow and the read value. Although, it is a reasonable aspect for the calibration which is comparing digital and analog measurement methods, the control mechanism of the experiment, in this case human eye and a ruler placed on the transparent reservoir could give erroneous results. In the report, it is also discussed how this kind of errors could be fixed and what solutions…

    • 1222 Words
    • 5 Pages
    Good Essays
  • Satisfactory Essays

    assignment

    • 515 Words
    • 4 Pages

    So with great honor we are asking for your permission to submit you our report.…

    • 515 Words
    • 4 Pages
    Satisfactory Essays

Related Topics