Electrical Machines - Questions and Answers
Information courtesy of ALSTOM.
INDUCTION MOTOR CONTROL GEAR
1. What are the main functions of control gear? 1. To provide a means of starting and stopping the motor and, at the same time, of limiting the starting current if required. 2. To give adequate protection to the motor under all conditions. 3. To allow speed changing when required. 4. To provide means of braking the motor when required. 5. To reverse the direction of rotation when required.
Protection of the motor must be automatic, but the other operations may be arranged to be under the control of an operator, or may be partly or fully-automatic.
2. What devices are required to give adequate protection to the motor? 1. Under-voltage release to prevent automatic restarting after a stoppage due to a drop in voltage or failure of the supply, where unexpected restarting of the motor might cause injury to an operator. 2. Overload relays for protection against excessive current in the motor windings - e.g. in the event of overload or failure of the motor. 3. Earth fault. 4. Single phase protection.
3. What provision must be made for short-circuit conditions in motor circuits?
Since overload relays are not designed to operate and clear the circuit in the event of a short-circuit. Circuit-breaker or fuse protection of sufficient breaking capacity to deal with any possible short-circuit that may occur must be provided.
4. What are the usual forms of overload relay in motor-control gear?
In small contactor starters, generally thermal relays, either of the 'solder pot' or bimetal type. With large contactors or oil switches, magnetic relays of the solenoid type with dashpots. Either type of overload relay may be used within intermediate sizes.
5. How do thermal relays work?
The bimetallic thermal relay consists of a small bimetallic strip that is heated by an element connected in series with the supply. When the current rises

You May Also Find These Documents Helpful

  • Satisfactory Essays

    OSHA Final Rule 2014

    • 415853 Words
    • 2343 Pages

    19. Lab Safety Supply. 2010b. Safety and Industrial Supplies: TITAN Double DRing Body Belts. See http://www.labsafety.com/TITAN-Double-D-Ring-BodyBelts_24529135/ (October 19, 2010).…

    • 415853 Words
    • 2343 Pages
    Satisfactory Essays
  • Satisfactory Essays

    Jamiyla Taylor Resume 3

    • 295 Words
    • 2 Pages

    Observe equipment operations so that malfunctions can be detected, and notify operators of any malfunctions.…

    • 295 Words
    • 2 Pages
    Satisfactory Essays
  • Good Essays

    Contactors: Relay and Coil

    • 1021 Words
    • 5 Pages

    Contactors and relays are devices that open and close a set or sets of electric contacts by the action of a solenoid coil. A contactor is used to control an electric load in a control system. Contactors make or break a set of contacts that controls the voltage applied to some load in cooling systems. A contactor consists of a coil that opens and closes a set of contacts due to the magnetic attraction created by the coil when it is energized. Magnetic starters are also used to start and stop large loads in cooling systems. The major difference between magnetic starters and contactors is that the magnetic starter houses its own overload. Different manufactures design contactors in different ways, but all accomplish the same purpose which is opening and closing a set of contacts. The armature of a contactor is the portion that moves. The sliding armature mounts between two slots in the frame of the contactors and moves up and down in these slots. The swinging armature is mounted on a pivot or hinge and moves up and down in a swinging motion.…

    • 1021 Words
    • 5 Pages
    Good Essays
  • Powerful Essays

    Chapter 9 Review Questions

    • 1133 Words
    • 5 Pages

    Which of the following is a common use of a shaded pole motor? A. Furnace fan motor.…

    • 1133 Words
    • 5 Pages
    Powerful Essays
  • Better Essays

    Exam 1 Part 2 Study Guide

    • 2293 Words
    • 10 Pages

    * Car’s speed reaches desired point and the system throttles back to maintain that speed…

    • 2293 Words
    • 10 Pages
    Better Essays
  • Good Essays

    English 101

    • 1529 Words
    • 7 Pages

    1. Describe the function of the following pieces of safety equipment and how each might be used: (10 points)…

    • 1529 Words
    • 7 Pages
    Good Essays
  • Powerful Essays

    Navy Tag-Out Users Manual

    • 3369 Words
    • 14 Pages

    The purpose of this manual is to: a. b. Provide for personnel and ship safety and prevent damage to equipment. Prevent improper operation when a component, equipment, system or portion of a system is isolated or in an abnormal condition. Prevent improper operation when a freeze seal is applied to a system or when other safety devices such as blank flanges are installed for testing, maintenance, or casualty isolation. Provide a procedure for use when an instrument is unreliable or not in its normal operating condition. Provide standard tag-out procedures. Provide a procedure for control of hazardous…

    • 3369 Words
    • 14 Pages
    Powerful Essays
  • Powerful Essays

    7. The primary purpose of internal control over plant and equipment is to safeguard the assets from theft. True False…

    • 5977 Words
    • 24 Pages
    Powerful Essays
  • Good Essays

    The philosophy of protective relaying is to provide protection or isolation to an area of the electric system that has a disturbance as quickly as possible to prevent damage to the power system. Along with this, you want to leave as much of the power grid in tact to continue service to the customers. Protective relaying helps protect equipment from damage due to abnormal operating conditions. Protective relaying does not prevent abnormal operating conditions but limits the amount of time these conditions can exist. Relaying can detect all kinds of abnormal operating conditions such as over-current, over-voltage, and under-voltage.…

    • 334 Words
    • 2 Pages
    Good Essays
  • Good Essays

    If a breaker fails to be triggered by a tripping order, as detected by the non-extinction of the fault current, this backup protection sends a tripping order to the upstream or adjacent breakers.…

    • 1426 Words
    • 7 Pages
    Good Essays
  • Good Essays

    Relays are important and underappreciated parts of everyday life. They are put to use a countless number of times, in a countless number of places. This is a complete over view of a relay and its use.…

    • 593 Words
    • 2 Pages
    Good Essays
  • Powerful Essays

    1.5 Some physical security controls are required by laws, e.g. fire exit door, fire alarm, etc.…

    • 4755 Words
    • 20 Pages
    Powerful Essays
  • Good Essays

    Reverse Engineering Paper

    • 2103 Words
    • 9 Pages

    When a relay receives power, power runs through a set of coils and creates a magnetic field that actuates an arm inside and closes the circuit. Relays are used as switches to control larger circuits with more power. Since a relay is able to control an output circuit of higher power than the input circuit, it can be considered to be a form of an electrical amplifier. When using a relay in a dc current, diodes are put in across the coil to dissipate energy from the collapsing magnetic field at deactivation, which would cause a spike in voltage and damage components if not there.…

    • 2103 Words
    • 9 Pages
    Good Essays
  • Good Essays

    A Buchholz relay is a gas and oil operated device installed in the pipework between the top of the transformer main tank and the conservator. A second relay is sometimes used for the tapchanger selector chamber. The function of the relay is to detect an abnormal condition within the tank and send an alarm or trip signal. Under normal conditions the relay is completely full of oil. Operation occurs when floats are displaced by an accumulation of gas, or a flap is moved by a surge of oil. Almost all large oil-filled transformers are equipped with a Buchholz relay, first developed by Max Buchholz in 1921.…

    • 538 Words
    • 3 Pages
    Good Essays
  • Satisfactory Essays

    Induction Motor

    • 282 Words
    • 2 Pages

    An electric motor is a device which transfers electrical energy in to mechanical energy which is either rotational or kinetic energy. There are two major classifications of electric motors on the basis of the type of electric input on which they operate obviously, AC and DC.…

    • 282 Words
    • 2 Pages
    Satisfactory Essays