Introduction

Distillation is a physical process used to separate chemicals from a mixture by how easy they vaporize. The temperature rises unit it reaches the temperature of the lowest boiling substance in the mixture while the other contents of the mixture remain in their original phase (until the most volatile substance has all boiled off) as it’s heated. Hot vapor results and passes into a condenser and is then converted to a liquid that’s collected in a receiver flask. The temperature of the gas phase rises again until it reaches the boiling point of a second content in the mixture and so on. By simple microscale distillation, we purified an unknown organic compound and then identified the unknown organic compound by using the boiling point and density measurements.

Procedure/Results

5 mL of the unknown impure organic A was collected in an Erlenmeyer flask. A simple distillation apparatus was assembled and 3 mL of the unknown impure organic A was transferred into the distillation flask along with 3 boiling chips. A thermometer was then suspended down the middle of the condenser to record the distillation temperature. The mixture was heated gently and a pure solvent started to collect in the distillation flask. Two different fractions were collected. The first one was the forerun, which was collected before the temperature stabilized and the second one was when the temperature of the boiling compound began to stabilize. The unknown impure organic A was identified using density and boiling point measurements collected. Another simple distillation apparatus was assembled to find the boiling point of the unknown impure organic A. 3 mL of the unknown impure organic A and 3 boiling chips were transferred into the distillation flask and heated gently until the substance started to boil. The unknown impure organic A produced 0.3 mL with a boiling point of 55°C for fraction one, which

You May Also Find These Documents Helpful

  • Satisfactory Essays

    Isolation of Unknown: 71 mL of boiling H2O were poured int an Erlenmeyer flask with 0.93 g of unknown to dissolve it. After reaching room temperature, the flask was placed into a bucket with ice and DI H2O. The unknown was collected by vacuum filtration, rinsed with ice water, and dried to constant mass at 0.72 g.…

    • 291 Words
    • 2 Pages
    Satisfactory Essays
  • Satisfactory Essays

    Exp 5 Soo Jin Park 73426

    • 326 Words
    • 2 Pages

    The purpose of this experiment is to determine the boiling point of a liquid and the melting point of a solid. It is useful to know the melting point and boiling point of a substance to identify whether it is pure or not. I could learn how to determine the melting and boiling point of a substance through its temperature when the acetamide turned into a liquid and bubbles emerged from the capillary tube in the Isopropyl alcohol.…

    • 326 Words
    • 2 Pages
    Satisfactory Essays
  • Good Essays

    Physical Properties- the physical properties were not the main source for determining the identity of the alkyl halide and starting alcohol because of the usual inaccuracy, however the results for boiling point and density proved close to 2-bromobutane and 2-Butanol. The boiling range from the week one experiment was 76-118 ◦C, which was too large of a range and the alkyl halide had not been completely purified. However, the boiling point for 2-butanol alcohol was about 83 ◦C, which lies within the range of the starting boiling range.…

    • 1325 Words
    • 6 Pages
    Good Essays
  • Good Essays

    Sludge Lab

    • 821 Words
    • 4 Pages

    I separated it simply by using the decanting technique. I carefully poured it off of the mixture of solids and into a separate plastic cup. Easy. The physical property of phase was used for separation. It was the only liquid in the mixture. Then I had to identify it. I smelled it and it had a permanent marker smell to it. That led me to believe it was an alcohol. Next, I tried measuring the density using a graduated cylinder and a balance. I measured the amount of alcohol I put in the graduated cylinder (volume) and how many grams it was on the balance (mass). The volume was 9.2cm3, the mass was 7.25g, and the overall density was .79cm3. That proved my liquid was not water. Finally, I tested the boiling point to determine what type of alcohol it was. I used a ring stand, thermometer, hot plate, test tube, and a beaker full of water. I placed the beaker full of water on the hot plate. I then filled the test tube with my liquid and attached it to the ring stand. Finally, I put the thermometer in the test tube and turned the hot plate on high. The liquid really started boiling around 78 degrees (Celsius), so I concluded that my alcohol was ethyl…

    • 821 Words
    • 4 Pages
    Good Essays
  • Satisfactory Essays

    Organic Chem Lab

    • 360 Words
    • 2 Pages

    cqt be 4eve'^i* lh )\ven svt,sraxe' tt rag alpl 5itr9 lvoodr,arilc ard g1*r6 rqt4 rvticllr 4gtd ftr eshHahng tt6 Po$'t\oh of rnaxl 6q* qb$rbq\r. rraeg lOqgtr in ,.1yq'iolef c1eetftrtstu^1'…

    • 360 Words
    • 2 Pages
    Satisfactory Essays
  • Good Essays

    Introduction: Simple distillation is a commonly used method to separate and purify the mixtures of organic liquids into their original components. Mixtures of two miscible liquids with two different boiling points were separated. Therefore, it can be said that the two organic compounds are separated by exploiting the different boiling temperatures of the liquids. Both vaporization and condensation were used in this experiment. The two organic compounds used in this experiment were ethyl benzene and cyclohexane, which have the boiling point of 136°C and 80.74°C, respectively. This experiment resulted…

    • 1803 Words
    • 8 Pages
    Good Essays
  • Good Essays

    In order to perform this experiment, a distillation apparatus was assembled. 4.0mL of H3PO4 and 3.0mL of cyclohexanol was placed in the round-bottom flask as sell as 5 drops of H2SO4 and a magnetic stir bar. The flow of water was then started through the condenser and the reaction mixture was heated while the magnetic stir rod began stirring. Once distillation was complete and no more liquid distilled, or the thermometer rose above 85 degrees Celsius, the heat was turned off and the products were collected in a small test tube. Once cooled, what was left was an organic top layer and a bottom layer. A Pasteur pipette was used to remove the majority of the bottom layer and was placed into a separate labeled container. Placing .25g of anhydrous calcium chloride into the test tube dried the top organic layer which was then left to stand for 5 min. a clean 5-mL vial was weighed and using a Pasteur pipette, the liquid was removed from the test tube and transferred to the tared sample vial and weighed.…

    • 314 Words
    • 2 Pages
    Good Essays
  • Good Essays

    O Chem

    • 729 Words
    • 3 Pages

    40ml of an equimolar mixture of cyclohexane and toluene was obtained and transferred into a 100ml round bottomed boiling flask which contained boiling chips. The distilling column was packed with metal sponge and the height was measured in centimeters and recorded. The distillation apparatus was assembled and a heat mantle was set. Several vials were used as fraction receivers. The vials were labeled, 1-4, and weighed prior to adding the liquid mixture and after the liquid was added. The temperature was recorded before adding heat in order to begin distillation (20º C). The temperature was recorded prior to each distillation fraction and after each 2ml of distillate which was recorded in table 1. The system was turned off and cooled down letting the remaining condensed vapor drain into the round bottomed flask. This sample was transferred by pipette into a vial…

    • 729 Words
    • 3 Pages
    Good Essays
  • Satisfactory Essays

    24 mL of 4-methylcyclohexanol, 5mL of phosphoric acid, and 1mL of concentrated sulfuric acid was added to a 250 mL round bottom flask and mixed thoroughly with a magnetic stirrer. A simple distillation set up was installed with a 250mL round bottom flask, jack, stirrer, heating mantle, and variac. The solution was heated gently with a small heating mantle to distill the crude product while keeping the vapor temperature around 100C or less. The crude product was collected which contained water, 4-methylcyclohexene, and trace acid.…

    • 331 Words
    • 2 Pages
    Satisfactory Essays
  • Good Essays

    Chemistry Experiment 2

    • 280 Words
    • 2 Pages

    1. How did your proposed procedures or flow charts at the beginning of this experiment compare to the actual procedures of this lab exercise?…

    • 280 Words
    • 2 Pages
    Good Essays
  • Good Essays

    The Aldehyde Enigma

    • 817 Words
    • 4 Pages

    Pavia D., Lampman G. M., Kriz G. S., and Engel R. G. A Small Scale Approach to Organic Laboratory Techniques, Third Edition).…

    • 817 Words
    • 4 Pages
    Good Essays
  • Better Essays

    Chem Lab

    • 858 Words
    • 4 Pages

    There are millions of different organic compounds. Most of them are found in mixtures and in order to achieve a pure form they need to be separated, isolated, and purified. However, there are endless numbers of possible mixtures, which make it impossible to have a pre-designed procedure for every mixture. So chemists often have to make their own procedures. The purpose of this experiment was to prepare the student to the real world by them designing their own procedure which will help them understand the techniques of separation and purification better. The goal was to extract two of the components of the mixture that consisted of 50% benzoic acid, 40% benzoin, and 10% dibromobenzene. The benzoic acid was extracted by the use of base and extraction technique. Then a crystallization was performed in order to separate benzoin by the use of hexane a solvent, leaving the dibromobenzne in the mother liquor. The percent recovery for benzoic acid was 91.8% and 80.3% for the benzoin. The MP for benzoic acid was 119-122°C (1) and 135-136°C (2)for the benzoin. The high percent recovery and closeness of measured MP to the literature value indicate that the designed procedure was successful.…

    • 858 Words
    • 4 Pages
    Better Essays
  • Good Essays

    Liquids and Solids

    • 384 Words
    • 2 Pages

    Purpose: The purpose of this experiment is to determine the boiling point of liquids and the melting…

    • 384 Words
    • 2 Pages
    Good Essays
  • Good Essays

    This experiment combined all the knowledge of the previous labs performed throughout the semester. An unknown mixture containing an organic acid or base and an organic neutral compound in nearly equal amounts needs to be separated to its separate components. An understanding of solubility, extraction, crystallization and vacuum filtration is necessary in order to successfully carry out the separation.…

    • 1426 Words
    • 6 Pages
    Good Essays
  • Good Essays

    Mixed Melting Points

    • 843 Words
    • 4 Pages

    The main purpose of this experiment was to identify an unknown compound/substance by performing multiple experimental melting point tests. Pure and impure solids were tested to see what affect pureness/impureness had on a melting point.…

    • 843 Words
    • 4 Pages
    Good Essays

Related Topics