Analysis of a Volatile Liquid
Analysis of a Volatile Liquid

Abstract: The purpose of this experiment was to use various methods of analysis to determine the identity of an unknown volatile liquid. In the first part of the experiment, the molecular mass was found by using water to find the volume of a flask through calculations and this as well as the mass of the gas of the unknown liquid were put into the a manipulated version of the ideal gas equation to determine the molar mass of the liquid, which was 14.21g per mole. The next part was used to determine the density of the volatile liquid. First the volatile liquid was placed in a pyncometer and massed; water was then placed in the same (now clean and empty) pyncometer and massed. The density equation was manipulated using the data for water to solve for the mL of the capillary tube. This new information was used to find the density of the liquid, which was 1.33g/mL. The last part of the experiment was used to determine the boiling point of the volatile liquid. A test tube was placed inverted in a flask filled with the unknown liquid that was in a water bath heating. When bubbles from the test tube slowed and began to go back into the test tube, the temperature was taken and this served as a measurement of the boiling point. The average measured boiling point was 60.2°C. The measured data was inadequate to identify the liquid with. The unknown liquid was revealed to be methanol; the revealed identity could then be used to compare the data to the actual information for methanol. The molar mass was found to have a percent error of 55.6%, the density had a percent error of 68.1% and the boiling point had one of 6.95%. The measured data for the boiling point was fairly accurate, but the molar mass and the density both had very large percent error. The reasons for this will be discussed more in the discussion.

Data:

Boiling Point Trial | Boiling Point (Degrees Celsius) | 1 | 63.2 | 2 | 59.3 | 3 | 58.1 |

Molar Mass Trial | Mass of Flask and Gas (g) | 1 | 29.118 | 2 | 29.120 | 3 | 29.129 | Item | Mass (g) | Flask (used for trials) | 29.111 | Flask (used with water) | 28.81 | Flask filled with water | 60.99 | Water | 32.18 |

Density Item | Mass (g) | Pyncometer | .058 | Pyncometer with volatile liquid | .078 | Pyncometer with water | .073 | Volatile liquid | .020 | Water | .015 |

Miscellaneous Data Item of Data | Value | Room Temperature | 25°C | Pressure of Room | .960atm |

Calculations:

Boiling Point

Average Boiling Point: (63.2+59.3+58.1)/3= 60.2° C
The average boiling point was found by adding each boiling point measured in each of the three trials and dividing this value by three.

Percent Error: {(64.7-60.2)/64.7} x100=6.95%
The percent error was found by subtracting the actual value from the theoretical and then dividing this value by the theoretical. This value is then multiplied by 100 to find a percent.

Molar Mass

Volume of the flask: 32.18g/0.9975g/mL=32.26mL
32.26mL/1000=0.03226
The density of water at room temperature was found to be .9975g/mL. The density equation was manipulated so that the volume of the container could be found by dividing the grams of water in the flask by the density of water. This was then converted to liters by dividing the amount of mL by 100 because there are 1000 mL in a liter.

Mass of gas: 29.129-29.111=.018g
To find the mass of the gas, the mass of the flask was subtracted from the mass of the flask with gas in it.

Molar mass of the volatile liquid: {.018g x 0.0821 x 298K}/(.960atm x .03226L)=14.21g
To find the molar mass the ideal gas equation is manipulated to find the molar mass. The equation was MM=gRT/PV. The grams of the gas was multiplied by the R constant and the temperature of the room. Then, this value was divided by the pressure of the room multiplied by the volume of the container.

Percent Error: {(32.04-14.21)/32.04}x100=55.6%
The percent error was found by subtracting the actual value from the theoretical and then dividing this value by the theoretical. This value is then multiplied by 100 to find a percent.

Density

Volume of Pyncometer: .015g/.9975g/mL=.015mL
The density of water at room temperature was found to be .9975g/mL. The density equation was manipulated so that the volume of the pyncometer could be found by dividing the grams of water in the pyncometer by the density of water.

Density of Volatile Liquid: .0209g/.015mL=1.33g/mL
To find the density the mass of a substance is divided by the volume so the grams of the liquid were divided by the mL of the container.

Percent Error: {(|.791-1.33|)/.791} x100=68.1%
To find the percent error the actual result is subtracted from the theoretical and the absolute value is taken for this value. This value is then divided by the theoretical and multiplied by 100 to find a percent.

Calculation Summary Data Table Calculation | Found Value | Average Boiling Point | 60.2°C | Percent error of boiling point | 6.95% | Volume of flask | 0.03226L | Molar mass of the volatile liquid | 14.21g | Percent error of Molar mass | 55.6% | Volume of Pyncometer | .015mL | Density of Volatile Liquid | 1.33g/mL | Percent Error of Density | 68.1% |

Discussion:

The purpose of this experiment was to analyze an unknown volatile liquid with various methods in order to identify the liquid. This experiment can also be used to determine which methods of identification were the most accurate in identifying the unknown liquid after the identity was revealed. The unknown volatile liquid was methanol. The first part of the experiment was to assess the molar mass of the volatile liquid. A flask was given a cover of aluminum foil and there was a pinhole put in the top. Some of the liquid was added and then evaporated by heating it in a water bath and the flask was massed following each subsequent adding and evaporating of liquid. The mass of the gas was found this way (the mass of the flask with gas in it was subtracted by the original mass of the flask); it was found to be .018g. The volume of the flask was found by filling the flask with water and using its available data about density and its mass to find the volume through a manipulated density equation. The molar mass was found by plugging in this information as well as the temperature and pressure of the room and the constant R into a manipulated ideal gas equation. The molar mass can be found this way because of the ideal gas theory. If any gas is not placed under extreme temperature or pressure conditions, it should in theory behave ideally and the equation can work. Since the liquid, and later gas, used in the experiment was under close to ideal pressure conditions and normal temperature conditions, the ideal gas equation should be fairly accurate. The molar mass that was found was 14.21g. However, the actual molar mass of methanol is 32.04. This means that there is a 55.6% percent error. The molar mass that was calculated was much lower than the actual, which accounts for the very large percent error. An error that could have caused this is that some of the gas may have escaped form the pinhole in the aluminum foil, as the hole was larger than what would be the size of a pin. This would cause the grams of the gas to be less and this also lowers the molar mass quite a bit, which accounts for the very large percent error. The molar mass of a substance is a good way to identify a substance because it is unique to the composition of a substance. However, the molar mass did not serve as a good way to identify the methanol in this experiment because of the large percent error. The next part of the experiment was to calculate the density of the unknown volatile liquid. The liquid was placed in a pyncometer and massed and then after the pyncometer was emptied water was placed in the same pyncometer and massed. Also the mass of the empty pyncometer was taken. From this information the density can be found because the density and mass of the water can be used to find the volume of pyncometer. From the volume and the mass of the unknown liquid the density can be calculated and it was found to be 1.33g/mL. Density is a good way to identify a substance because density is fairly unique. Not many substances, if any, will have the same exact density. This is because density is the mass of the substance divided by the volume and little to no substances share the exact same criteria to have the same density. The actual density of methanol is .791g/mL. The percent error of the density is 68.1%. Because this percent error is so large there must be a very large error in the experiment. A possible error could be that there may have been excess of the methanol in the pyncometer before the water was placed in it. This would alter the calculated volume of the pyncometer to be less than it actually was. With the volume being less, this would make the density be much larger than it should be, which accounts for the very large percent error. The final part of the lab was to measure the boiling point of the unknown liquid. A beaker of the liquid was placed in a water bath and heated with an inverted test tube placed in the liquid. After heating, a stream of air bubbles would come from the inverted test tube. At some point, the bubble were no longer air, but were actually methanol vapor. Once there was a steady stream of bubbles, the beaker with the liquid was removed from the water bath and as the bubbles stopped. This is when the temperature was taken. This is because as the bubbles were moving, the vapor had greater pressure than the atmosphere, but when they stopped before moving back into the test tube, the atmospheric pressure was equal to the vapor pressure. The boiling point of a substance is when the vapor pressure equals the atmospheric pressure, so this is why it was taken at that moment. The boiling point of a substance is very unique for these reasons. The average boiling point that was measured was 60.2° C. The actual boiling point of methanol is 64.7°C. This means that the percent error of the boiling point was 6.95%. The error is not that great, but an error that could have accounted for a lower measured boiling point is that the thermometer used takes a long time to show the correct temperature. There is a lag time where the thermometer does not show the correct reading. This would cause the measured boiling point to be lower than the actual and this accounts for the error.
Post Lab Questions 1. The molar mass that was found was 14.21g. However, the actual molar mass of methanol is 32.04. This means that there is a 55.6% percent error ({(32.04-14.21)/32.04}x100=55.6%). The calculated density found to be 1.33g/mL. The actual density of methanol is .791g/mL. The percent error of the density is 68.1% ({(|.791-1.33|)/.791} x100=68.1%). The average boiling point that was measured was 60.2° C. The actual boiling point of methanol is 64.7°C. This means that the percent error of the boiling point was 6.95% ({(64.7-60.2)/64.7} x100=6.95%). 2. The method that produced data that was closest to the actual data for methanol was the test for boiling point, which only yielded a percent error of 6.95%. This error is not large, but it still could not conclusively lead to the identification of the liquid. There are many other substances with boiling points close to 60°C. When the other data is included and used to identify the liquid, it is impossible to conclusively identify the substance as the correct liquid methanol because the data strays so much from the actual data. 3. The fundamental idea of the Ideal Gas Model relies on the idea that the gas is behaving ideally. This means that there are no intermolecular forces between the molecules of the gas, the molecules obey Newton's law of motion, the molecules move in all direction with equal probability, and the molecules undergo elastic collisions with the walls. The volatile liquid should have behaved ideally because it was not tested under extreme pressure or temperature conditions, both of which cause gasses to no longer behave as ideal. The fact that it should have behaved as ideal is the very reason that the ideal gas equation could be used. 4. These methods of identifying the molar mass, density, and boiling point could not be used with gallium because it is not a liquid at room temperature and its boiling point is very high. In testing the molar mass and the boiling point, the gallium would have to be heated to very high temperatures (each time for the vaporization of the gallium) and the lab materials would not be able to heat it up to the necessary temperature. This temperature would also have to be sustained for massing, and this would be impossible in the lab conditions. Octane could be tested, but it is not a liquid at room temperature so the increased temperature would have to be sustained for testing. It is also not as volatile as methanol and would prove difficult to identify because it has many different isomers, each with a distinct molar mass and density. Butane could in theory be tested, but it is much more volatile than methanol and would even have to be cooled to behave as a liquid. Because of this, it is very difficult to test the boiling point in the method that was used for the lab. The water bath that the methanol was heated in, would not have to be heated and the lab could not be performed at room temperature, it would need to be done at around 1°C, which is not very plausible for the lab conditions. Out of all of these substances water would be the easiest one to test as it is a liquid at room temperature and it has a fairly low boiling point, as does methanol. However, much of the data was determined by using water itself to find missing variables and so the water would be compared with itself. This does not limit its ability to be tested in any way, but it does allow for a lot error in comparing the unknown, but secretly water with itself. 5. The measurement errors for the molar mass calculation piece of the lab include an inaccurate measurement of the mass of the gas in the flask and in inaccurate calculation for the volume of the flask. For the mass of the gas, some escaped through the pinhole in the top of the flask and this greatly lowered the molar mass. The volume of the flask should have been greater, which actually made the molar mass slightly more than it should have been. These errors did not cancel each other out as the molar mass was still much lower than it should have been. This means that the mass of the gas affected the data much more than the inaccurate volume did.

Sources: http://www.sigmaaldrich.com/chemistry/solvents/methanol-center.html http://misterguch.brinkster.net/molarmass.html http://www.phys.hawaii.edu/~teb/java/ntnujava/idealGas/idealGas.html http://www.chemicool.com/elements/gallium.html

You May Also Find These Documents Helpful

  • Satisfactory Essays

    Isolation of Unknown: 71 mL of boiling H2O were poured int an Erlenmeyer flask with 0.93 g of unknown to dissolve it. After reaching room temperature, the flask was placed into a bucket with ice and DI H2O. The unknown was collected by vacuum filtration, rinsed with ice water, and dried to constant mass at 0.72 g.…

    • 291 Words
    • 2 Pages
    Satisfactory Essays
  • Satisfactory Essays

    Exp 5 Soo Jin Park 73426

    • 326 Words
    • 2 Pages

    The purpose of this experiment is to determine the boiling point of a liquid and the melting point of a solid. It is useful to know the melting point and boiling point of a substance to identify whether it is pure or not. I could learn how to determine the melting and boiling point of a substance through its temperature when the acetamide turned into a liquid and bubbles emerged from the capillary tube in the Isopropyl alcohol.…

    • 326 Words
    • 2 Pages
    Satisfactory Essays
  • Good Essays

    Ap Chemistry Lab Report

    • 678 Words
    • 3 Pages

    In this experiment, the molecular weight of a condensed vapor was found through a procedure using an unknown liquid. The flask before adding the unknown liquid in was full of air. After the beaker full of water started to boil the flask was examined until the unknown liquid was completely vaporized. At that exact point the flask contained all vapor. At the final weighing the flask contained condensed vapor and air. There is always a chance for error. Some sources of error could have come with completing this lab over an open water bath and some water vapor may have been in place. Also, too much vapor could have escaped and the experiment might not have been stopped quick…

    • 678 Words
    • 3 Pages
    Good Essays
  • Good Essays

    The goal of this experiment was to separate Toluene and Hexane by distillation and gas chromatography based on their difference in boiling points. The boiling point of hexane is 69 degrees Celsius and the boiling point of toluene is 110 degrees Celsius. Three fractions were collected for both simple and fractional distillation. The first fraction was hexane since it had the lower boiling point. The second fraction was a mixture of toluene and hexane. The third fraction was toluene since it had the high boiling point of 110 degrees Celsius. Gas chromatography was also preformed on each of the fractions from simple and fractional distillation. In the gas chromatography process, the compounds are carried through a stationary phase, and pushed…

    • 395 Words
    • 2 Pages
    Good Essays
  • Satisfactory Essays

    There were a numerous amount of observations and patterns in the data throughout the candle lab. The hypothesis was if the amount of candles inside the jar increases by an increment of one, then the weight of water in the jar will increase as well. The hypothesis was proven to be true, since for every candle added there was about 33 grams of water more. Every time the jar was placed over the candles, there would always be bubbles around the rim, also as more candles were used, the jar became cloudier and the bottom of the jar became more charred. The bottom of the jar also got hot, and after the jar was taken off the candles there would be grey smoke. The flame got larger as more candles were added, and the smell remained constant.…

    • 439 Words
    • 2 Pages
    Satisfactory Essays
  • Better Essays

    Mixture Analysis Lab

    • 1046 Words
    • 5 Pages

    An unknown sample, # 12-Green, was separated into its individual variable components, iron, ammonium chloride, silicon dioxide, and sodium chloride. The techniques used to separate the components of unknown # 12-Green, magnetism, sublimation, extraction, and filtration, were chosen based on the unique properties of each component. Using these separation techniques, each substance was extracted and the composition of unknown # 12-Green was 16% Fe, 15% NH4Cl, 59% SiO2, and 9% NaCl with a 1% uncertainty due to the loss of 0.0369g of the initial mass.…

    • 1046 Words
    • 5 Pages
    Better Essays
  • Good Essays

    Molar Volume Lab

    • 736 Words
    • 3 Pages

    The purpose of this lab was to make an experimental determination of molar volume. The molar volume is found by using a form of the equation PV=nRT. The first set of pressure, volume, and temperature are found throughout the experiment. The second set of pressure and volume are the STP. The molar volume obtained is 22.7 L/mol. The accepted molar volume is actually 22.4 L/mol. This gives the experiment a percent error of 1.339%. Experimental error could be that either excess or not enough HCl was used. This could be a reason for the .3 difference in the molar volume obtained in the experiment and the accepted…

    • 736 Words
    • 3 Pages
    Good Essays
  • Good Essays

    Molar Mass Lab

    • 709 Words
    • 3 Pages

    There are several ways to find the molar mass of a substance. One way, if the substance is a gas, is to use the Ideal Gas Equation to find molar mass. The standard equation reads PV=nRT where “n” is the number of moles present, “P” is the pressure (which is obtained by reading the barometric pressure of the room with the class barometer), “V” is the volume of the gas, “R” is the universal constant, and “T” is the temperature of the gas. The experiment’s objective is to calculate the experimental value of molar mass of a volatile liquid through the process of heating (to form a gas, and thus use the ideal gas law to calculate the molar mass), and compare the results to the accepted value for the analysis of accuracy. This can be achieved by substituting the mass of the substance over the molar mass of the substance for “n”: m/M=n. The liquid heated to a gas is methanol, which has an accepted value for molar mass of 32.05g/mol.…

    • 709 Words
    • 3 Pages
    Good Essays
  • Satisfactory Essays

    Lab for Chemistry

    • 397 Words
    • 2 Pages

    The purpose of the Density Lab was to determine the identity of four unknown solids and two unknown liquids by calculating their densities and comparing them to a density chart, taking into account error analysis and finally classifying the substances. In order to calculate this density, we first found the mass of the container that was to be holding the substances. We then found the volume of the substance, and lastly determined the mass of the container and substance. We subtracted (Container + Substance) – Container to find the mass of simply the substance. In order to distinguish density, we took the final mass divided by the volume, and identified the substances based on Density Charts we found online. Originally we hypothesized that we would be able to identify these substances based on the densities we calculated, yet this proved to be harder than it seemed, however our hypothesis was correct. We now could concluded the densities and identification. The density of Unknown Liquid 1 was 1.26 which was found to be Colorless Glycerin (also density of 1.26) and Unknown Liquid 2 was 0.88 or Rubbing Alcohol (colorless). Unknown Solid 1 has a density of 7.20 or Iron, Solid 2 is 2.59 and Aluminum, Solid 3 is 5.47 and Tin, while Solid 4 has a density of 9.81and Nickel? We…

    • 397 Words
    • 2 Pages
    Satisfactory Essays
  • Satisfactory Essays

    Unknown liquid

    • 264 Words
    • 2 Pages

    III. Procedure: 1.We massed an empty 10mL graduated cylinder to the nearest .01g. 2.Then, we filled the graduated cylinder with 4.0-5.0 mL of distilled water, 3.massed it to the nearest 0.1 ml and 4. recorded the data. Then to determine the density of the unknown liquid; we repeated the steps.…

    • 264 Words
    • 2 Pages
    Satisfactory Essays
  • Good Essays

    Liquids and Solids

    • 384 Words
    • 2 Pages

    Purpose: The purpose of this experiment is to determine the boiling point of liquids and the melting…

    • 384 Words
    • 2 Pages
    Good Essays
  • Satisfactory Essays

    PURPOSE: The purpose of this experiment is for the students to get a better knowledge with the laboratory tools and techniques. This experiment taught me how to convert between SI units and standard American units of mass, length, temperature, volume and time as well as how to measure the units. Students become proficient in laboratory techniques such as measuring temperature and volume and calculating within them.…

    • 1411 Words
    • 11 Pages
    Satisfactory Essays
  • Good Essays

    The Chemist Analysis

    • 448 Words
    • 2 Pages

    I am reading, “The Chemist”, By Stephanie Meyer. It is about a character named Alex, who is an Ex-Agent for the top-secret government program dealing with terrorism. Alex had been approached in hiding by her former agency who needed her help with one of the most dangerous men in the world, who withheld a super-flu to extinct all human population. Within the novel, there are many diverse characters that can identify with pieces of music. Often times, music can be relatable in that people put their feelings into the text.…

    • 448 Words
    • 2 Pages
    Good Essays
  • Good Essays

    Lab Experiment

    • 519 Words
    • 3 Pages

    The purpose of this lab was to determine if a there is a change in mass when a gas is produced and determine if gas has mass. To conduct this experiment, the group must be careful not to let the Alka-Seltzer tablet get wet before the bottle is closed by wiping the lip of the bottle and the cap so it remains dry, or risk gas escaping into the air and not being captured by the bottle. Also, the group must be sure to close the bottle tightly with the cap, because gas may escape this way as well. During this investigation, it was determined that there is 0 change in mass when a gas is produced, because the mass of the bottle, water, Alka-Seltzer tablet, and cap remained the same even after the Alka-Seltzer had a chemical reaction with the water and…

    • 519 Words
    • 3 Pages
    Good Essays
  • Satisfactory Essays

    5. You will be using several equations in this unit with variables you may not have seen before.…

    • 354 Words
    • 3 Pages
    Satisfactory Essays