Preview

Experiment 3 prelab

Good Essays
Open Document
Open Document
345 Words
Grammar
Grammar
Plagiarism
Plagiarism
Writing
Writing
Score
Score
Experiment 3 prelab
Chem-102 Lab
Dr. Sobhi

Experiment #3: Spectrophotometric Determination of Tartrazine

Purpose
The objectives of this lab include- illustrating the use of the spectrophotometer in chemical analysis, and generating a standard, or calibration curve, then using that curve to determine the value of an unknown substance. The spectrophotometer is one of the most powerful tools used in chemistry to find the concentration of substances in solution. It compares the colors of a known and an unknown solution, that comparison then leads to a quantitative estimate of the concentration of trace amounts of colored materials in that solution.

Chemicals and Materials
40 mL standard Tartrazine solution
Yellow Dye
Safety goggles
100 mL beaker
De-ionized water
Cuvette
Lint-free Tissue
Gloves (Latex-free)
Spectrometer with Labquest
Logger-Pro
USB drive

Procedure
Acquire 40mL of the standard tartrazine solution in a 100mL beaker. Make sure the beaker is clean and dry.
Dilute the original standard solution into the following concentrations in separate beakers using de-ionized water.
Prepare 3 different solutions:
7.5mL standard + 2.5mL deionized water (75% solution)
5.0mL standard + 5.0mL deionized water (50% solution)
2.5mL standard + 7.5mL deionized water (25% solution)
After all of the solutions are prepared, obtain a cuvette from your professor (special sample cell).
Prepare a blank, by filling up your cuvette ¾ with deionized water.
Wipe down the outside of each cuvette with the lint-free tissue.
Handle only at the top edge, and while using gloves.
Dislodge all bubbles.
Always position cuvette so that light passes through the clear sides
Connect the spectrometer to LabQuest and choose New from the File menu.
Calibrate Spectrometer:
Put the blank cuvette into the Spectrometer.
Choose the calibration option on the Sensors Menu.
Determine the Optimal Wavelength for creating this standard curve and set up on the data-collection mode.
Now, you

You May Also Find These Documents Helpful

  • Satisfactory Essays

    Experiment 1 Procedures

    • 537 Words
    • 3 Pages

    Experiment 1: Bromination of Acetanilide1 Precautions: Ethanol is flammable Sodium hypochlorite is an oxidizing agent and releases toxic fumes (handle in fume hood) Acetic acid is corrosive, harmful if inhaled, flammable and can cause burns (handle in fume hood) Gloves are recommended to avoid chemical contact with skin Reaction Scheme: Conversion of acetanilide to p-bromoacetanilide…

    • 537 Words
    • 3 Pages
    Satisfactory Essays
  • Satisfactory Essays

    Dye Analysis Lab Report

    • 978 Words
    • 4 Pages

    2) Based on maximum absorbance of the dye tested, select the appropriate wavelength on spectrometer.…

    • 978 Words
    • 4 Pages
    Satisfactory Essays
  • Satisfactory Essays

    Lab 11 Experiment 1

    • 184 Words
    • 2 Pages

    Coal mining, particularly surface mining, leads to large areas of land being temporarily disturbed. The mine workings collect and conduct water that is in contact with the widespread pyrite, a mineral that produces iron and sulfuric acid when exposed to air and water. In this lab, you will see first-hand the reasons why mine drainage can be harmful to the local drainage system if left untreated.…

    • 184 Words
    • 2 Pages
    Satisfactory Essays
  • Satisfactory Essays

    Experiment 4a

    • 440 Words
    • 2 Pages

    We placed the zinc inside the beaker and slowly poured the hydrochloric acid into the beaker. As soon as the acid entered the beaker, there was a sizzling sound and bubbles started to form as we add more of the substance in. When the bubbles were forming, we could see a steam of gas coming out of the beaker. After 10 minutes, we noticed bits of zinc were floating on top of the hydrochloric acid and lining the beaker. I lifted the beaker and felt the bottom and it felt warm, which meant the reaction was still happening. After 20 minutes, we added water into the zinc and hydrochloric acid to stop the reaction and we observed a slight cloudy colour (still clear) forming as we slowly pour the water in the beaker.…

    • 440 Words
    • 2 Pages
    Satisfactory Essays
  • Satisfactory Essays

    experiment 1

    • 301 Words
    • 2 Pages

    (3) Using a vacuum filtration, filter the solution into a clean, dry Erlenmeyer flask with a side arm.…

    • 301 Words
    • 2 Pages
    Satisfactory Essays
  • Best Essays

    Spectroscopy is the study of light. A spectrophotometer is a machine used to determine the absorbance of light at any given wavelength. It does this by using a source of white light through a prism, which gives multiple wavelengths that can be individually focused (Ayyagari and Nigam, 2007). Substances are put into cuvettes that are glass or quartz containers that light can easily travel through. The light that is being focused travels through the substance gets absorbed by the substance and is reflected back and read by galvanometer which had the ability to detect electric currents (Verma, R). The absorbance reading is then given, absorbance is usually between 0.0 – 2.0, any higher than 2.0 may mean not enough light is getting through to the galvanometer (Bhowmik and Bose, 2011). When using the spectrophotometer it is necessary to use a control or blank to zero or tare the machine in between every new wavelength or concentration, this control is water (Ayyagari and Nigam, 2007). The correlation between the numbers acquired through spectroscopy can be seen using the Beer- Lambert Law. The Beer- Lambert law states that the amount of light absorbed at a certain wavelength is proportional to the concentration of the absorbing substance (Fankhauser, 2007).…

    • 2210 Words
    • 9 Pages
    Best Essays
  • Satisfactory Essays

    4. Add crucible contents to a beaker then add 200 mL water and 125 mL of solution and stir.…

    • 396 Words
    • 2 Pages
    Satisfactory Essays
  • Good Essays

    2. One 10.00mL portion was pipeted into a clean 100mL volumetric flask and dilute to the mark.…

    • 401 Words
    • 3 Pages
    Good Essays
  • Good Essays

    1. Label five 100-mL beakers 1–5 and clean the bottom of each beaker. 2. Draw a large “X” across the bottom on the outside of each beaker. Place the beakers on an overhead projector stage or a light box so that students can view the “X.” 3. Using separate graduated cylinders for the solution and water, measure and add the required amounts of 0.15 M sodium thiosulfate and distilled water to each…

    • 1476 Words
    • 6 Pages
    Good Essays
  • Good Essays

    This experiment will test the suggestion that the enthalpy change between a metal and a solution of a salt is related to the relative position of the two metals in the reactivity. Presumably the further apart in the series the bigger the enthalpy change will be.…

    • 679 Words
    • 3 Pages
    Good Essays
  • Good Essays

    EXPERIMENT 1

    • 2241 Words
    • 10 Pages

    The three different gas classes have different heat capacities. This is because molecules absorb heat differently, since there is three type of movements in molecules; translation, vibration, and…

    • 2241 Words
    • 10 Pages
    Good Essays
  • Better Essays

    Spectrophotometer is an optical instrument that measures and shows how much light energy is transmitted by a substance in solution at different wavelengths of radiant energy. Light passes into a monochromator where only a very narrow range of wavelengths can pass through. From there, light is transmitted through a sample solution, and on to a phototube where the light energy is converted to an electric current that is registered on a meter. To measure the amount of light absorbed by the solutes in sample solution, comparison to the initial intensity of light reaching the solution is needed. Each solution with a different solute has its own characteristic absorption property or spectrum. Spectrophotometer can also be used to find out the concentration of compounds in solution because the amount of light absorbed is directly proportional to the concentration of absorbing compounds in that sample. When a solution like bromophenol blue absorbs certain wavelengths of light in the visible spectrum and transmits or reflects others, it appears coloured. However, water is a colourless solution because it absorbs only wavelength outside of the visible light spectrum. By analysing the pattern of wavelength absorbed by a given sample, spectrophotometer can be used to distinguish compounds as different compounds absorb light at different wavelength. Figure 1 shows the schematic diagram of the components in a spectrophotometer.…

    • 3281 Words
    • 13 Pages
    Better Essays
  • Good Essays

    garlic as pectiside

    • 678 Words
    • 3 Pages

    Garlic originated in Central Asia and has now spread across the world. For use as an insecticide it should not be grown using chemical fertilisers. This is because heavy doses of fertiliser reduce the concentration of the effective substances in the garlic. It has anti-feedant, bacterial, fungicidal, insecticidal, nematicidal and repellent properties.…

    • 678 Words
    • 3 Pages
    Good Essays
  • Better Essays

    Experiment No. 1

    • 1343 Words
    • 6 Pages

    2. To perform the proper applications of the statistical methods/ concepts on determining the weight variations of samples…

    • 1343 Words
    • 6 Pages
    Better Essays
  • Powerful Essays

    Experiment Report

    • 1478 Words
    • 6 Pages

    a. To know the principles of good measurement and to compare the precision and accuracy of some commonly used measuring devices.…

    • 1478 Words
    • 6 Pages
    Powerful Essays