It may be recalled that a d.c. generator can be run as a d.c. motor. In like manner, an alternator may operate as a motor by connecting its armature winding to a 3-phase supply. It is then called a synchronous motor. As the name implies, a synchronous motor runs at synchronous speed (Ns = 120f/P) i.e., in synchronism with the revolving field produced by the 3-phase supply. The speed of rotation is, therefore, tied to the frequency of the source. Since the frequency is fixed, the motor speed stays constant irrespective of the load or voltage of 3phase supply. However, synchronous motors are not used so much because they run at constant speed (i.e., synchronous speed) but because they possess other unique electrical properties. In this chapter, we shall discuss the working and characteristics of synchronous motors.

11.1 Construction
A synchronous motor is a machine that operates at synchronous speed and converts electrical energy into mechanical energy. It is fundamentally an alternator operated as a motor. Like an alternator, a synchronous motor has the following two parts: (i) a stator which houses 3-phase armature winding in the slots of the stator core and receives power from a 3-phase supply [See (Fig. (11.1)]. (ii) a rotor that has a set of salient poles excited by direct current to form alternate N and S poles. The exciting coils are connected in series to two slip rings and direct current is fed into the winding from an external exciter mounted on the rotor shaft. The stator is wound for the same number of poles as the rotor poles. As in the case of an induction motor, the number of poles determines the synchronous speed of the motor:

Fig.(11.1)

293

Synchronous speed, N s = where

120f P

f = frequency of supply in Hz P = number of poles

An important drawback of a synchronous motor is that it is not self-starting and auxiliary means have to be used for starting it.

11.2 Some Facts about

You May Also Find These Documents Helpful

  • Good Essays

    * What is the function of a generator in a power plant? Convert mechanical energy to electrical…

    • 1410 Words
    • 6 Pages
    Good Essays
  • Powerful Essays

    Chapter 9 Review Questions

    • 1133 Words
    • 5 Pages

    Which of the following is a common use of a shaded pole motor? A. Furnace fan motor.…

    • 1133 Words
    • 5 Pages
    Powerful Essays
  • Good Essays

    A simple alternator consists of a coil which is rotated in a permanent magnetic field. The emf generated I the rotating coil is connected to a load via:…

    • 1234 Words
    • 5 Pages
    Good Essays
  • Powerful Essays

    20. What removes the starting winding from the electrical circuit of an open type split phase motor once it reaches 75% of its operating speed?…

    • 606 Words
    • 3 Pages
    Powerful Essays
  • Good Essays

    Motor Control

    • 1668 Words
    • 5 Pages

    Scenario: Walking down a 45 degree slope with a surfboard under my left arm and a large mountaineering backpack on my back.…

    • 1668 Words
    • 5 Pages
    Good Essays
  • Powerful Essays

    Dc Motors

    • 702 Words
    • 3 Pages

    A series DC motor connects the armature and field windings in series with a common D.C. power source. The motor speed varies as a non-linear function of load torque and armature current; current is common to both the stator and rotor yielding I^2 (current) squared behavior[citation…

    • 702 Words
    • 3 Pages
    Powerful Essays
  • Good Essays

    The fixed speed WECS starts to produce power when the wind speed is higher than the cut-in speed (3-4 m/s). At a speed higher than the rated wind speed (13 to 15 m/s), the power captured by the turbine is limited either by active/passive stall or pitch control of the rotor blades [23]. At a speed higher than the cut-out speed (around 25 m/s), the turbine is stopped by either full stall or full pitch of the blades to protect the turbine and generator from possible damage [23]. The rotating speed of large fixed speed turbines is normally in the range of 6 to 15 rpm, whereas the induction generator operates at much higher rpm (750 rom to 1800 rpm). The generator operating speed is determined by the number of poles and grid frequency…

    • 960 Words
    • 4 Pages
    Good Essays
  • Good Essays

    The induction generator described above can be adapted to operate at variable speed by the application of power-electronic frequency converters. Similar converters are widely used in general industry to provide variable speed drives (usually motors). In wind turbines, variable-speed operation has the big advantage that the inertia of the rotating parts serves to smooth out the torque fluctuations and significantly reduces stresses on the mechanics. The majority of large wind turbines…

    • 730 Words
    • 3 Pages
    Good Essays
  • Powerful Essays

    Pico Hydro Power

    • 5502 Words
    • 23 Pages

    9.1 Safety Warning 9.2 Electrical Standards 9.3 Earth-fault protection 9.4 Generator Options 9.5 Using 3-Phase Induction Motors as Single-Phase Generators. 9.6 Electronic Load Control 9.7 Alternatives to load control 9.8 Selection and Sizing of Generator, Capacitors, Cable and Protection Equipment 9.9 Installation and Connection…

    • 5502 Words
    • 23 Pages
    Powerful Essays
  • Better Essays

    Synchronous Generators

    • 1173 Words
    • 5 Pages

    Synchronous generators or alternators are synchronous machines used to convert mechanical power to ac electric power. Nowadays, an isolated synchronous generator supplying its own load independently of other generators is very rare. Such a situation is found in only a few out-of-the-way applications such as emergency generators. For all usual generator applications, there is more than one generator operating in parallel to supply the power demanded by the loads.…

    • 1173 Words
    • 5 Pages
    Better Essays
  • Best Essays

    Speed Reduction Gearbox

    • 4075 Words
    • 17 Pages

    Reduction gearboxes are used in all industries where power transmission occurs; they reduce speed and increase torque. They can be found between the prime mover (electric motor, gas, diesel or steam engine, etc.) and the driven equipment (conveyors, mills, paper machines, elevators, screws, agitators, etc.). An industrial gearbox is defined as a machine for the majority of drives requiring a reliable life and factor of safety.…

    • 4075 Words
    • 17 Pages
    Best Essays
  • Satisfactory Essays

    Dc Machines

    • 607 Words
    • 3 Pages

    1. Describe operation of DC machine (motor and generator) using illustrations. Specifically explain the purpose of: a. brushes d. armature winding b. split ring commutators e. effect of back emf (in operation) c. field winding 2. Draw the different configurations of DC machines a. shunt c. separately excited b. series 3. Develop, using Kirchhoff’s laws, equation for Ea (armature voltage) in both motoring and generating mode. 4. Describe three (3) methods of speed control in DC machines. 5. A shunt dc motor has P poles and is rotating at speed N rpm. The machine windings are lap wound. There are z armature conductors and a parallel paths. The flux developed is ɸ webers per pole. Derive an expression for the armature voltage developed in terms of ɸ, N, z, p and a. 6. A 30 hp, 230 V, 1150 rpm shunt motor has four poles, four parallel paths and 882 armature conductors. The armature circuit resistance is 0.170 . At rated speed and rated output the armature current is 110 A and the field current is 2.2 A. Calculate: a. the electromagnetic torque b. the flux per pole c. the rotational losses d. the efficiency e. the shaft load f. the field flux is reduced by 15% of its original value by means of a field rheostat. Determine the new operating speed. 7. A separately excited dc motor when operated at constant flux has an armature resistance of 1.03 Ω. When the motor is operated at no load from a 50 V supply, it develops a speed of 2100 rpm and draws a supply current of 1.2 A. Determine: a. the numerical value of Ka b. the no load rotational losses c. the electromagnetic torque developed by the motor d. the output power of the motor when operating at 1700 rpm from a 48 V supply 8. A 30 HP, 250 V, 1150 rpm shunt motor has four poles. There are 1200 armature conductors. The armature is lap wounded and has a circuit resistance of 0.18 . At rated speed and rated output the armature current is 100A and…

    • 607 Words
    • 3 Pages
    Satisfactory Essays
  • Better Essays

    An Improved Control Strategy for DFIG System and Dynamic Voltage Restorer under Grid Voltage Dip Peng Cheng, Heng Nian, Member, IEEE College of Electrical Engineering, Zhejiang University, Hangzhou, China cheng_peng@zju.edu.cn Abstract:With the increasing percentage of wind power in the utility grid, grid codes require that wind turbines must have low voltage ride through (LVRT) capability. Considering that doubly fed induction generation (DFIG) systems have the tolerance capability , to overcome the drawback of LVRT operation of DFIG system using crowbar, a dynamic voltage restorer (DVR) is connected to the stator side to prevent the stator voltage fast changing, and then the rotor side converter (RSC) can be in normal operation. A mathematical model of the rotor voltage of DFIG during a symmetrical voltage dip is presented to describe the allowable changing rate of the stator voltage. A new connection structure of DVR is proposed where DVR and GSC share a DC capacitor. Based on the coordinated control of the DFIG system and DVR, the active power regulation and reactive power compensation can be implemented under the grid fault.…

    • 3959 Words
    • 16 Pages
    Better Essays
  • Better Essays

    Power Plant

    • 13162 Words
    • 53 Pages

    LEARNING OBJECTIVES Upon completion of the chapter you will be able to: 1. State the principle by which generators convert mechanical energy to electrical energy. 2. State the rule to be applied when you determine the direction of induced emf in a coil. 3. State the purpose of slip rings. 4. State the reason why no emf is induced in a rotating coil as it passes through a neutral plane. 5. State what component causes a generator to produce direct current rather than alternating current. 6. Identify the point at which the brush contact should change from one commutator segment to the next. 7. State how field strength can be varied in a dc generator. 8. Describe the cause of sparking between brushes and commutator. 9. State what is meant by "armature reaction." 10. State the purpose of interpoles. 11. Explain the effect of motor reaction in a dc generator. 12. Explain the causes of armature losses. 13. List the types of armatures used in dc generators. 14. State the three classifications of dc generators. 15. State the term that applies to voltage variation from no-load to full-load conditions and how it is expressed as a percentage. 16. State the term that describes the use of two or more generators to supply a common load. 17. State the purpose of a dc generator that has been modified to function as an amplidyne.…

    • 13162 Words
    • 53 Pages
    Better Essays
  • Satisfactory Essays

    Induction Motor

    • 282 Words
    • 2 Pages

    With the advent of electrical energy distribution systems and their universal adoption throughout the world for the purpose of lightening and power the field of electric motors especially the AC type has shown a remarkable development in all prospects all over the world. As a result of the technological advancements the engineers throughout the world tried their best of best to come out with the most energy efficient and safe machines particularly, in the context of electric motors.…