Preview

Steel Plant EAF Electrical System

Satisfactory Essays
Open Document
Open Document
399 Words
Grammar
Grammar
Plagiarism
Plagiarism
Writing
Writing
Score
Score
Steel Plant EAF Electrical System
The modern steel plant receives low current, high voltage power from the generators of the electrical utility company. The purpose of the steel plant primary transformer is to step-down this voltage. The transformer thus provides high current, low voltage power for the EAF furnace. Large furnaces with transformers rated at 100MVA or higher is not uncommon.
There are usually two stages to this process. The transformer first steps-down the voltage from high to medium levels. There are different standards for a "medium-level voltage" in different countries; usually between 30 to 33 kV for Europe and Japan, but for the USA it is usually 34.5 kV. Finally, a heavy duty furnace transformer powers the EAF. This special furnace transformer is designed to allow the electric arc to operate within the desired current and voltage range.
To safeguard the EAF electrical system from the primary power supply are two types of switches: a vacuum switch and a motorized disconnect switch. These two switches are designed to isolate the EAF electrical system from the primary transformer in case of an emergency.
Other electrical systems around the EAF are the delta closure, the power cables, the current conduction arm, and the electrode holders. The power cables provide a connection between the delta closure and the current conducting arm. It is usually made of copper wires, with a rubber water jacket around the outside for water-cooling the cables. The power cable is connected with the current conducting arm, usually made of copper clad steel or aluminum alloys. This system weighs a lot less than the old bus-bar design that a lot of the older furnaces used. The current conducting arm conducts current directly from the power cable to the electrode holders. The electrode holders must withstand thermal cycling (not so much for our furnace, since our furnace should have a continuous feed) and severe mechanical loading and wear due to vibrations, torsion forces and

You May Also Find These Documents Helpful

  • Good Essays

    Nt1310 Final Exam

    • 931 Words
    • 4 Pages

    e. Filament Transformer- a step down transformer that is located between mA selector and filament. It increases the current to heat the filament and decrease voltage. The mA selector provides precise current to the step down transformer.…

    • 931 Words
    • 4 Pages
    Good Essays
  • Good Essays

    Nt1320 Unit 4

    • 540 Words
    • 3 Pages

    The power Rating for the Inverter transformer (KVA) = 2.0KVA, E2= 24V Assuming the efficiency of transformer= 85%:…

    • 540 Words
    • 3 Pages
    Good Essays
  • Good Essays

    Contactors: Relay and Coil

    • 1021 Words
    • 5 Pages

    Contactors and relays are devices that open and close a set or sets of electric contacts by the action of a solenoid coil. A contactor is used to control an electric load in a control system. Contactors make or break a set of contacts that controls the voltage applied to some load in cooling systems. A contactor consists of a coil that opens and closes a set of contacts due to the magnetic attraction created by the coil when it is energized. Magnetic starters are also used to start and stop large loads in cooling systems. The major difference between magnetic starters and contactors is that the magnetic starter houses its own overload. Different manufactures design contactors in different ways, but all accomplish the same purpose which is opening and closing a set of contacts. The armature of a contactor is the portion that moves. The sliding armature mounts between two slots in the frame of the contactors and moves up and down in these slots. The swinging armature is mounted on a pivot or hinge and moves up and down in a swinging motion.…

    • 1021 Words
    • 5 Pages
    Good Essays
  • Satisfactory Essays

    310 network lab 3

    • 533 Words
    • 3 Pages

    It is very important to prevent power surge powers with the equipment and hazard shock to people…

    • 533 Words
    • 3 Pages
    Satisfactory Essays
  • Powerful Essays

    The most effective method is to wholly contain the equipment in an electrically conductive enclosure, termed a Faraday cage, which prevents thelectromagnetic field from gaining access to the protected equipment. However, most such equipment must communicate with and be fed with power from the outside world, and this can provide entry points via which electrical transients…

    • 2230 Words
    • 9 Pages
    Powerful Essays
  • Satisfactory Essays

    11 kv inline Cable joints at Telfa Gold Mine 11 kv RMU switch gear terminations. 630 amps and 200 amps’ elbow terminations 11kv transformer flit plug terminations 11kv in line cable joints at Degrussa copper mine 11kv pole top termination, 11kv RMU 630 amps’ elbow terminations 11kv transformer flit plug terminations…

    • 51 Words
    • 1 Page
    Satisfactory Essays
  • Good Essays

    The 'War of Currents'

    • 518 Words
    • 2 Pages

    Westinghouse and Tesla 's AC generators overcame these disadvantages as, through the use of transformers, the voltage could be increased or decreased as was required. This allowed AC to be generated at moderately low voltages, increased to high voltages when needed to journey long distances, and…

    • 518 Words
    • 2 Pages
    Good Essays
  • Good Essays

    Both blast and electric arc furnaces are used in industrial settings to heat and mold metal. A blast furnace is used to make steel from liquid iron, while an electric arc furnace is used to make steel from scrap material. Electric arc furnaces use two different types of electrical currents to create heat. Blast furnaces force air into the bottom of the furnace into a heated stove area. The heat from the blast furnace's stove area converts the forced air into heated air to melt metal.…

    • 1371 Words
    • 6 Pages
    Good Essays
  • Good Essays

    Welding power sources are correctly rating and duty cycle is exercised for the job; they are properly installed by qualified electricians and are maintained in good condition.…

    • 1124 Words
    • 5 Pages
    Good Essays
  • Powerful Essays

    Steel Making Methods

    • 1959 Words
    • 8 Pages

    The first step in the process, is to make the steel itself. The most common method of steel making, constituting for over 60% of worldwide production uses a Basic Oxygen Furnace (BOF). This process includes taking over 75% pig iron and reducing it to a low-carbon steel in an abundance of oxygen. The second type utilises Electric Arc Furnaces (EAFs). This involves melting up to 100% recycled scrap and reforming it using the heat produced from electrical arcs between highly charged electrodes.…

    • 1959 Words
    • 8 Pages
    Powerful Essays
  • Good Essays

    Introductory overviewAlmost all coal, nuclear, geothermal, solar thermal electric, and waste incineration plants, as well as many natural gas power plants are thermal. Natural gas is frequently combusted in gas turbines as well as boilers. The waste heat from a gas turbine can be used to raise steam, in a combined cycle plant that improves overall efficiency. Power plants burning coal, oil, or natural gas are often referred to collectively as fossil-fuel power plants. Some biomass-fueled thermal power plants have appeared also. Non-nuclear thermal power plants, particularly fossil-fueled plants, which do not use co-generation are sometimes referred to as conventional power plants.…

    • 1083 Words
    • 5 Pages
    Good Essays
  • Satisfactory Essays

    Application Electric iron, toaster, fused wire Fused wire: a low-melting point wire connected in series with electric devices for safety. Electric power…

    • 294 Words
    • 2 Pages
    Satisfactory Essays
  • Satisfactory Essays

    ACB Presentation

    • 323 Words
    • 6 Pages

    CIRCUIT BREAKER CIRCUIT BREAKER IS A MECHANICAL SWITCHING DEVICE CAPABLE OF MAKING , CARRYING AND BREAKING SERVICE CURRENTS. IT SHALL ALSO MAKE , CARRY FOR A SPECIFIED TIME AND BREAK UNDER SPECIFIED ABNORMAL CONDITIONS SUCH AS A SHORT CIRCUIT . LVSM8.PPT/NRS BASIC FUNCTIONS OF A CIRCUIT BREAKER TO MAKE, CARRY & BREAK SERVICE CURRENTS TO PROTECT THE SYSTEM AGAINST ABNORMAL CONDITIONS LIKE OVER LOAD, SHORT CIRCUIT AND EARTH FAULT TO PROVIDE THE RIGHT DISCRIMINATION TO ENSURE CONTINUOUS SUPPLY TO ALL HEALTHY FEEDERS IN CASE OF A FAULT ON ONE FEEDER TYPES OF L.T. CIRCUIT BREAKERS OIL CIRCUIT BREAKERS AIR CIRCUIT BREAKERS MOULDED CASE CIRCUIT BREAKERS MINIATURE CIRCUIT BREAKERS MOTOR PROTECTION CIRCUIT BREAKERS CONTACT MECHANISM OF ACB ARC CHUTE ARCING CONTACT…

    • 323 Words
    • 6 Pages
    Satisfactory Essays
  • Powerful Essays

    Answer: A. ASME section I B. ASME Section II : - Rules for construction of power boiler. : - Materials. Part A – Ferrous materials. Part B – Non-Ferrous materials. Part C – Specification for electrodes & filler wire. Part D – Properties. ASME Section IV : - Rules for construction of Heating Boiler. ASME Section V : - Non- destructive Examination. ASME Section VI : - Recommended rules for care & operation of heating boiler. ASME Section VII : - Recommended guidelines for care of power boiler. ASME Section VIII : - Rules for construction of pressure vessels. (Division I & II) ASME Section IX : - Welding & Brazing qualification.…

    • 21336 Words
    • 86 Pages
    Powerful Essays
  • Good Essays

    by coke oven, regenerative flame furnace technology and melting by electric arc furnace, technologies of…

    • 4937 Words
    • 20 Pages
    Good Essays