Preview

Simple and fractional distillation of a mixture

Good Essays
Open Document
Open Document
590 Words
Grammar
Grammar
Plagiarism
Plagiarism
Writing
Writing
Score
Score
Simple and fractional distillation of a mixture
Theory: Distillation is the conversion of a mixture of substance into vapors which is afterwards condensed to the liquid form. It cans separation or purification of substances by taking advantage of differences in volatility. The purpose of this lab is comparing the efficiency of two distillation methods with the mixture of ethanol and 1-butanol. in theory the fractional distillation should be more efficient because of the steel sponge. The sponge acted as surface area for gas to condense on. This prevented some of the 1-butanol from condensing into the vial during fraction A because it would condense onto the sponge and drip back down into the flask. The boiling point of 1-butanol is higher than the boiling point of ethanol, so the cooler surface of the sponge helped condense 1-butanol, but the ethanol still made it to the vial because of its lower boiling point. The sponge helped improve efficiency of the distillation. We will use distillation plot and gas chromatography to test it.
To draw the distillation curve graph , we counted the number of drops and temperature. The graph shows us the specific spots (large number drops) have a little change in temperature.it means that a compound has been distilled off and it shows on the horizontal line. On the vertical line of the graph shows us the temperature change with no drops, it means that the transition between the two compounds boiling points. From the two graph, the horizontal line indicate the boiling point of two compounds and vertical lines indicate the transition between the boiling point, we can see the fractional curve has a higher boiling point than sample curve and simple distillation separated the majority of the two compounds near the beginning and the end of the distilling process, fractional distillation produced much more effective.
For the chromatography, we use it for determine the purity of sample. In GC, Due to interactions between the organic compounds in the sample and the stationary

You May Also Find These Documents Helpful

  • Good Essays

    The objective of this lab was to prepare n-butyl bromide or n-bromobutane, which is derived from an alcohol and an acid. In this case, n-butyl alcohol and sulfuric acid were the reagents. There were two methods of distillation that was involved in this experiment. The first was by reflux distillation, which is used to speed up a chemical reaction without having the reactants/ products evaporate or explode. Data Table 1 indicates the amount of each reagents that was prepared for the reflux apparatus. However, the reagents, sodium bromide, water, and butanol, were combined and cooled in an ice bath previously before transferred to the apparatus. Sulfuric acid was then slowly added to the cooled mixture, causing the solution to turn a dark yellow.…

    • 768 Words
    • 4 Pages
    Good Essays
  • Better Essays

    DIals Alder

    • 733 Words
    • 3 Pages

    To a 100 mL flask, 22 mL of Diclopentadiene was added and arranged for fractional distillation into an ice-cooled receiver. In order for the diene to distill, heat was applied to the dimer with a microburner. Into a 50 ml round bottom flask boiling chips were added before starting the distillation . Within about 5 mins while reaching a steady boiling point…

    • 733 Words
    • 3 Pages
    Better Essays
  • Satisfactory Essays

    Orgo Lab 5

    • 539 Words
    • 3 Pages

    This experiment was carried out as described in Class Pak. The heat source power was set to 3 for fractional distillation and to 2 for simple distillation. For both processes, aluminum foil was wrapped around the heat source and flask to trap the heat and speed up the process.…

    • 539 Words
    • 3 Pages
    Satisfactory Essays
  • Powerful Essays

    Objective: The main goal of this lab is to learn how separation of binary liquid mixtures is performed. Especially when the two liquids have boiling points varying by about 30° C. Hexane can be separated from toluene in this experiment because of the difference in their boiling points. Since toluene has a higher boiling point, it will left at the bottom while the hexane starts to boil out and collect in the Hickman still. GC measurements help us in determining how accurate our data is by making a graph of the amount of hexane and toluene in each fraction. Also this lab gives experience with semi-micro distillation in order for experiments in the future that might need this purification setup.…

    • 1041 Words
    • 5 Pages
    Powerful Essays
  • Good Essays

    Distillation Lab Report

    • 418 Words
    • 2 Pages

    Conclusion: During this lab I learn how to do simple and fractional distillation. Although the group I worked with only did simple distillation, I carefully observed how the group that did the fractional distillation. We collected all the results, to have a more precise range on what the results were. One way to produce an error in this process would have been if our procedures were done wrong or reversed or if we placed the compounds in a improper…

    • 418 Words
    • 2 Pages
    Good Essays
  • Good Essays

    Pharmacists can use it to find out how much of each chemical is in each product.…

    • 595 Words
    • 3 Pages
    Good Essays
  • Good Essays

    The distillation procedure is initiated by gradually heating the mixture until it reaches the temperature of the liquid with the lower boiling point. This liquid then turns into a vapor and leaves to mixture and is collected by the set up apparatus. In fractional distillation a vigreux column is used. This provides for surface area for condensation to occur. At each condensation event the vapor is enriched in the low boiling point component and the liquid is enriched in the high boiling point component. The surfaces where condensation occurs are called theoretical plates. Separation is more efficient when there are more theoretical plates. Therefore, fractional distillation is more efficient in separating than simple distillation. Another new technique was gas chromatography. Gas chromatography is used to separate volatile components of a mixture. First, a small amount is draw up into a syringe and the contents of the syringe are placed into a hot injector pot of the gas chromatograph. The components of the mixture evaporate into the gas phase inside the injector. A carrier gas flows through the injected and pushed the…

    • 395 Words
    • 2 Pages
    Good Essays
  • Good Essays

    The volume of 20 mmol of 2-methylcyclohexanol was calculated and transferred into a round-bottom flask. Then 0.7 mL of 85 % phosphoric acid was mixed in. The reaction vessel was clamped to a ring stand over a suitable heat source and an apparatus was assembled for simple distillation using a Hickman still, water cooled condenser, and thermometer. Then a conical vial was weighted and recorded. After turning on the heat source in slow power, it was waited until it started to distillate. The temperature when it began was 58°C. Using a Pasteur pipet, the distillate was regularly transferred into the conical vial until only a yellow solution remained. It wasn’t left to dry completely. The temperature was 75°C when the vessel was taken from the heat source. The distillate was then washed with 1.5 mL of 5 % aqueous sodium bicarbonate. Then the aqueous lower layer was carefully removed. The upper layer was cloudy at first until it started to become clear after a few minutes. The solution was dried through anhydrous calcium chloride. Then it was weighted.…

    • 698 Words
    • 2 Pages
    Good Essays
  • Good Essays

    Since simple distillation is a physical process, it separated the two chemicals from the mixture based on how easily they vaporize. As the mixture was heated, the temperature rose until it reached the temperature of the lowest boiling substance in the mixture which was cyclohexane. The temperature at which the first drop was collected was 79.5oC and the distillation of cyclohexane was stopped when the still-head temperature was 94.5oC . Therefore, the boiling range of cyclohexane in this experiment was 79.5oC- 94.5oC.The resultant hot vapor passed through into the condenser and was converted into liquid, which was then collected into a graduated cylinder. During this time, the ethyl benzene remained in its original phase. Since cyclohexane had a lower boiling point, it is considered to be more volatile in comparison to ethyl benzene. After a plateau in temperature was observed, the temperature was increased in order for ethyl benzene to reach its boiling point. The temperature at which ethyl benzene was collected was 127oC and the distillation of ethyl benzene was stopped when the still-head temperature was 138.5oC. The boiling range for ethyl benzene was observed to be in between 127oC-138.5oC. The liquids were collected in increments of 4mL. The first 28mL collected were of cyclohexane and the last 16 mL collected were of ethyl benzene,…

    • 1803 Words
    • 8 Pages
    Good Essays
  • Good Essays

    The experiment started by gathering the supplies for distillation. In the vial, 2mL of 2-methylcyclohexanol and 1mL of phosphoric acid is added. The solvents are thoroughly mixed and a few boiling chips is added to help with the…

    • 1090 Words
    • 5 Pages
    Good Essays
  • Good Essays

    O Chem

    • 729 Words
    • 3 Pages

    40ml of an equimolar mixture of cyclohexane and toluene was obtained and transferred into a 100ml round bottomed boiling flask which contained boiling chips. The distilling column was packed with metal sponge and the height was measured in centimeters and recorded. The distillation apparatus was assembled and a heat mantle was set. Several vials were used as fraction receivers. The vials were labeled, 1-4, and weighed prior to adding the liquid mixture and after the liquid was added. The temperature was recorded before adding heat in order to begin distillation (20º C). The temperature was recorded prior to each distillation fraction and after each 2ml of distillate which was recorded in table 1. The system was turned off and cooled down letting the remaining condensed vapor drain into the round bottomed flask. This sample was transferred by pipette into a vial…

    • 729 Words
    • 3 Pages
    Good Essays
  • Good Essays

    Gas Chromatography Essay

    • 921 Words
    • 4 Pages

    The area of the peaks on the chromatogram is proportional to the concentration of analytes in the sample, so concentrations can be determined, making GC a quantitative method.…

    • 921 Words
    • 4 Pages
    Good Essays
  • Good Essays

    Based on the theoretical and actual refractive index of both simple and fractional distillation we can determine the success of the experiment. The results are also supported by general conditions of distillation. The actual refractive index for the simple distillation was very similar to the theoretical index we calculated.(Simple- 1.3903 at 22.1 degrees versus Fractional 1.3707 at 22.9) The theoretical refractive index was 1.397 at 20.5 degrees. If depicted in graph form, the lines would match up more closely than the refractive qualities in the fractional distillation. Simple distillations are best separated with two compounds whose boiling points have a difference greater than 30 degrees celsius. The difference between cyclohexane and 2-methylpentane is 52.74 degrees.(cyclohexane-80.74-2 methypentane-28).…

    • 274 Words
    • 2 Pages
    Good Essays
  • Good Essays

    Gas Chromatography Lab

    • 940 Words
    • 4 Pages

    The purpose of this experiment was to learn how to use distillation and gas chromatography to separate and identify different compounds from a given mixture. There are several kinds of distillation methods. However, the method that we used in this experiment was fractional distillation. This method is used when trying to separate two different volatile compounds whose boiling points differ by 40-50°C or more. If the boiling points are too close, this method will not work because the two compounds will begin evaporating at close temperatures and will condense down to the receiving flasks at relatively the same times. This will not create an ideal separation. The apparatus used for this type of distillation…

    • 940 Words
    • 4 Pages
    Good Essays
  • Good Essays

    Steam Distillation

    • 614 Words
    • 3 Pages

    Steam distillation is used to isolate eugenol rather than simple distillation because the boiling point of eugenol is 250°C, which means the compound would most likely decompose if it were distilled directly. Eugenol is also immiscible with water.…

    • 614 Words
    • 3 Pages
    Good Essays

Related Topics