Rates of Reaction - Experiment
The Aim of the experiment:
In this experiment I will investigate the relationship between the concentration of the hydrochloric acid and the rate of a reaction. To find this out I will react different concentration of hydrochloric acid and magnesium, from there I will monitor the gas (hydrogen) produced and analyse the results. Prediction:
I predict the higher the molarity of the hydrochloric acid the faster the rate of reaction therefore the quicker the gas will be produced in the specific time interval. Overview of the experiment:
In this reaction two substances will be present in the solution, magnesium and hydrochloric acid. During the reaction magnesium particles will collide with the hydrochloric acid particles to produce the salt Mg chloride and hydrogen gas. The amount of gas will be monitored at certain time intervals to find out the rate of reaction. However I will be changing the molarity of the HCl by diluting it with water. The water molecules will prevent the Mg and HCl particles to collide, this is because the water molecules will get in the way of the collisions therefore providing an obstacle for the two reacting particle. This will have an influence on the rate of reaction it will make it slower. Background information:
Magnesium is in the group 2 metals that are quite similar to group 1 metals in the periodic table, except that it has 2 electrons on its outer shell and forms 2+ ions, so in general Mg is quite reactive. This is because Mg can easily loose its 2 outer electrons, the result of this is that it will react rather vigorously as two different particles react. It is not enough for the particles to collide, the bonds between the atoms they have to be broken before new molecules can be produced. In liquids their particles are continually moving at various speeds, which then collide in different ways. There are different ways of collisions occurring which have different effects such as ‘head on’ and ‘glancing’ collisions. The particles that contain a lot of kinetic energy (at a high temperature) collide with a large force therefore gain a heavy contact with another particle (head on). This is known to be successful and a reaction takes place. Where as a ‘glancing’ collision the particles have not got enough kinetic energy (at a low temperature) to produce a reaction because the contact is not great enough, so a reaction will not occur.
There is another factor that affects the rate of reaction this is the activation energy. If the activation energy is high then the success rate is much less. In chemical reactions, if the activation energy is low, a high proportion of collisions will have enough energy and so the reaction is fast. Reactions in which the activation energy is high are very slow at room temperature, because only a very small fraction of collisions have enough energy to overcome the activation energy. The success rate of collisions is low. The word and formula equation for the reaction-taking place are:
Word equation:
Magnesium + Hydrochloric acid Magnesium chloride + Hydrogen Formula equation: Mg (s) + HCl (aq) MgCl2 (aq) + H2 (g)

The variables and fair testing These are the variables that will influence the rate of the reaction, such as the following;
Concentration of hydrochloric acid,
Volume of hydrochloric acid,
The dimension of the magnesium ribbon,
How many magnesium strips in the acid solution,
Temperature of the surrounding,
Size of the beaker.
The device to measure the gas produced,
The amount of cotton wool, These factors have to be measured very accurately to keep the experiment fair and also to keep the results of the experiment reliable. One of the main factors is the concentration of the hydrochloric acid; this chemical must be measured exactly to what concentration it needs to be. If the concentration is higher than it is suppose to be then more molecules will occur therefore an increased amount of collisions between the particles will happen. The conclusion to this is that the rate of reaction will increase, because the higher the concentration the faster the rate of reaction. The volume of hydrochloric acid must always be 25cm3. if there is more than this amount then there would be more molecules in the solution therefore collisions will take place much more frequently. This will have an effect on the rate of reaction to increase; this is because collisions of molecules are parallel with rate of reaction. The diameter and the length of the Mg must be the same because the more surface area of the Mg the longer the reaction will take to finish. So at all stages of the experiment the dimension of the Mg must be the same. The rate of reaction is also influenced by how many Mg strips are present in the acid solution. Through out the experiment there will always be one Mg strip In the solution if there is more than this then the reaction time will increase because the Mg ribbons will provide an increased amount of surface area so there will be more Mg particles to collide with the acid particles. The experiment will take place in room temperature so each time a reaction happens it will have the same amount of temperature surrounding it. It is important for the temperature to be the same, as it will have a massive influence to the amount of collisions. If the temperature is increased then the particles motion will increase as will there for the contacts between the opposite particles will be heavy and in parallel the success rate would have increased making the reaction time faster. The opposite will happen if a low temperature surrounds the solution. The size and volume of the beaker has to be the same. The beaker is where the reaction is going to take place. The material of the beaker must be the same as well; I will use glass because it is highly transparent which is very easy to see through where as plastic is not. The device to measure how much hydrogen (gas) is produce must be constant the whole experiment because the same accuracy needs to be applied to monitor the gas given off. The cotton wool plug must have the same mass through out the experiment because this would have an influence to the overall weight. The cotton wool must also block the entire opening of the conical flask so whilst the reaction is taking place none of the solution is lost. Preliminary Data Diagram of the experiment:
Cotton wool

Other equipment:

Safety goggles, ruler, measuring cylinder, pipit, and dry cloth.

Magnesium
Ribbon

Hydrochloric acid

Method of the preliminary experiment:
· Set up the equipment like the diagram above.
· I measured 25 cm3 of 1M hydrochloric acid by a measuring cylinder then added it into a conical flask on the weighing scale including the cotton ball. I noted the reading on the scale at the start.
· I then measured 8cm length of Mg ribbon and inserted it into the conical flak and immediately placed the cotton wool on and started the stop clock.
· I read the weighing scales every 15 seconds for 1minute and 30 seconds. Then I recorded the results in the table
· I repeated the experiment two more times.

Time (s)
Reading on the weighing scales (g)
Trial 1
Trial 2
Trail 3
Average
0
79.54
79.03
79.92
79.49
15
79.60
79.12
79.60
79.44
30
79.58
79.10
79.57
79.41
45
79.55
79.09
79.52
79.38
60
79.54
79.08
78.99
79.20
75
79.59
79.06
78.97
79.20
90
79.58
79.04
78.94
79.18 Preliminary experiment:
The first part of the preliminary experiment the method I used wasn’t accurate enough to measure the gas produced. This is because the weighing scale I had used, to measure the gas produced was not appropriate because the scale wasn’t accurate as there was no decimal places on the scale to measure the hydrogen produced. This problem was resolved by using a more accurate weighing scale to measure precisely how much gas was produced during the reaction. The weighing device I had used to do this experiment had measured the weight by two decimal places this was enough to measure exactly how much hydrogen was produced. A problem had occurred with using this weighing device. The scale was too sensitive, so the weight increased with movement that was surrounding it this had given anomalous results. Whilst carrying out the first trial, I had realised that the reaction between hydrochloric acid and magnesium lasted quite short amount of time because when it got to the last minute the reaction had already finished. This is why I had chosen to record the weight down of the reaction every 15 seconds instead of 30 seconds. So I had chosen to monitor the amount of the gas produced every 15 seconds. I had calculated the average by the three trials that I had investigated on. I have decided to approach this experiment another way when I do my actual rate of reaction experiment. The reason being was that it was difficult to use the weighing scales to carry out this experiment so instead for my actual experiment I will be monitoring the gas produced by the syringe. This is because the syringe will identify more accurately on how much gas is produced during the reaction, as delicate movement does not affect it. The actual experiment:
The 5 different concentrations of hydrochloric acid I will be using in my experiment are, 0.3M, O.4M, 0.5M, 0.6M and 0.7M. I will achieve these concentrations by diluting 1M of HCl with water. I will have my weakest concentration to be 0.3M because the reaction would not be too slow this would save a lot of time because if I use 0.1M the reaction would be very slow. So using 0.3M as the weakest concentration would be appropriate because it would show the reaction at a decent time scale. I have decide 0.7M to be the strongest concentration this also is appropriate because the reaction wouldn’t be too fast so it would be easy to record the amount of hydrogen produced in the acquired time interval. Carrying out 5 different concentrations would let me see a trend once I create graphs from my results thus giving me a wide range of results to analyse. For each concentration I will carry out 3 trials just like I had done for the preliminary experiment this would give me an average and make my results more reliable. This table shows the concentration I will be using for my experiment: Volume of 1M acid (cm3)
Volume of water (cm3)
Concentration of acid
Solution (M)
30
70
0.3
40
60
0.4
50
50
0.5
60
40
0.6
70
30
0.7

Dependent and Independent variables: My dependent variable in this experiment will be the temperature and the dimension of the magnesium ribbon. The length of the Mg ribbon will be 8cm and the experiment will be held at room temperature this will be constant through out the whole experiment. In this experiment there will only be one independent variable this is the molarity of the hydrochloric acid. This is going to going to vary time to time in different stages in the experiment, this is because I will be investigating how this affects the rate of reaction.

Prediction for Independent variable: In my experiment I will have the hydrochloric acid as the independent variable. I predict that if I decrease the molarity of the HCl then more time will be taken for the rate of reaction to occur. This is because fewer particles will be present in the solution so less chances of collisions taking place with the Mg particles, so the reaction will be slower. The way I will decrease the molarity of the HCl is by diluting a certain proportion of water into the hydrochloric acid while decreases the amount of HCl. As there will be fewer particles in lower concentrations of HCl then there will be a lower probability of the particles overcoming the activation energy, as it will be more difficult for the particles especially in room temperature to create a successful reaction.

Safety precautions during the experiment; Ensure all coats and bags are put to the side to prevent accidents (tripping), so the working area is tidy,
Wear safety goggles at all times during this experiment,
Be careful when handling chemicals,
Clean the surface area if spillage has occurred with a dry cloth,
Work at a steady pace to avoid accidents.
When diluting the hydrochloric acid pour the water into the acid, prevents splashes.

The method of the experiment: Step 1- Set up a retort stand with a clamp firmly fixed onto it. Then in-between the jaws of the clamp place the syringe firmly in. connect the delivery tube with the syringe ensure no space is left. Step 2- Measure the amount of hydrochloric acid and water needed (depends what stage) to get the correct molarity in a 100cm3 measuring cylinder for each liquid. Use a pipit for better accuracy and ensure the meniscus level is correct to the correct to the right measurement acquired, carry this out on a balanced surface for better accuracy. Step 3- Then dilute the water with the HCl into one measuring cylinder. The total should be 100cm3; this should give the required molarity. Step 4- From this measuring cylinder pour in 25cm3 of the solution into a conical flask. Measure 8cm of Mg ribbon, condense the 8cm of Mg ribbon so it can fit through the opening of the conical flask. Step 5- Get a partner to prepare the stopwatch, make sure the display reads 00.00 seconds. Put the 8cm of Mg ribbon in the conical flask containing the 25cm3 solution, immediately close the plug with the delivery tube stuck on it securely and start the time. Step 6- One person in the group should be responsible for reading the gas (hydrogen) produced on the syringe as the judgement needs to be unique. One person should read the time and one person to record the results. Step 7- Then every 15seconds record the amount of gas produced by reading the syringe stop until the time gets to 90seconds. Step 8- Drain out the conical flask and rinse the flask with water then dry it with a clean dry cloth. Step 9- Re-do this exact method two more times. This will increase reliability and the 3 outcomes for each molarity and time interval can be found a mean.

Analysis: My graphs show as the time increases the amount of hydrogen gas also increases, during the reaction between hydrochloric acid and magnesium. I have realised that the time and the amount of gas produce are parallel to each other but then again when the concentration of HCl increased to 0.5M the line started to curve slightly. The graphs 0.3M and 0.4M there is a direct proportional change between the hydrogen released and the rate of reaction. Between 0 to 90seconds the reaction was constant. I think this illustrates that the concentration of HCl was too low and the proportion of its particles was dominated by the water molecules in the solution, which had prevented the reacting particles to collide. This is the reason for the reaction to be slow as the collisions occurred less frequently as shown by the straight line on the graphs. The activation energy has to be kept at a minimum to make it easier for particles especially at room temperature to create a successful collision. If the activation energy is high then a small fraction of collisions have enough energy to overcome the activation energy and the success rate of collisions is low, but in this experiment I had no control of the activation energy. The 0.5M graph is were the curve starts to develop but going further onto 0.6M there is more proof of the curve being formed. So therefore the last graph 0.7M of HCl displays an obvious curve shown at the tip of the best-fit line. The rate of reaction at 0.7M was quite rapid because the HCl was highly concentrated so it contained a lot of particles to collide with the magnesium, which had obviously created many successful collisions. The collisions were more frequent so the reaction was fast and vigorous, this is why 0.7M had the most recognizable curve. The curve just shows that the reaction is almost finished. By this particular graph I am convinced that if I had reacted 0.9M of HCl with Mg I would see a definite curve with the line completely flattened out between the time interval of 0 to 90seconds. All five graphs show as the concentration increases so does the rate of reaction, before carrying out my experiment I knew this would happen as the collision theory has justified this point already, the higher the concentration of an acid the more frequent the collisions will occur therefore faster the rate of reaction. All my results prove this fact to be true. The trend for each graph shows the gas produced increases with the time. The amount of gas produced for each time interval for all the graphs are different for example 0.3M of HCl shows at 15 seconds the hydrogen released was 2.8cm3 but 0.4M the gas produced was 3.3cm3 at that same time. This is another factor that clarifies at higher concentrations hydrogen released is quicker therefore faster the rate of reaction.

This table shows the rate of reaction for each concentration of HCl.
Concentration of HCl (Molarity)
Rate of reaction (cm3/s)
(2d.p)
0.3
4.4/30= 0.15
0.4
6.1/30= 0.20
0.5
9.3/30= 0.31
0.6
13.7/30= 0.46
0.7
17.4/30= 0.58

Another key factor is the gradient for each graph. This analysis the rate of reaction on how the concentration influences the outcome of the speed of the reaction. The gradient shows the actual speed of the whole reaction. The graph 0.6M the gradient was 0.46cm3/s this is almost three times the amount for the 0.3M graph (0.15cm3/s) accordingly this tells me if the concentration is doubled the gradient increases three times more this declares the fact how the concentration of an acid influences the rate of the reaction. I have come to a conclusion that as the concentration of HCl had increased the gas produced at each time interval had also increased therefore the rate of reaction was fast. As I had mentioned before the primary factor to rate of reaction is the amount of reacting particles in a solution. If there is a low concentration of particles then the probability of them colliding would be low as well so the reaction would be slow. However at higher concentrations the collisions are much more frequent so the probability of successful collisions are likely. This is because there is a greater possibility for particles to collide with enough kinetic energy in addition to overcome the activation energy. I had made a prediction at the beginning of the experiment which was, the higher the concentration of the hydrochloric acid the faster the rate of reaction therefore the quicker the gas production will be in the specific time interval. After having done the practical work on rate of reaction I have come to realise that my prediction is correct.

Evaluation: The results I received from my experiment I think are very precise because I had designed 5 graphs that had different concentrations of HCl and none of them contained an anomalous point. The best-fit line for all the lines had the plots either on it or very close to it so this is how it can be justified that my results from my experiment are accurate. I think the syringe method was a suitable procedure to investigate the rate of reaction (gas given off) because the syringe did gather the amount of hydrogen released during the reaction pretty accurately. The other positive factor about using this method is that it was very easy to obtain the results and to repeat the same procedure two more times. There were downsides to this experiment, which had not been as precise as the other factors with in the whole experiment this was the excess water remaining in the conical flask. This had occurred because I only had one conical flaskto carry out the entire experiment with and the opening of the conical flask was too narrow, subsequently I couldn’t dry the excess water off after having to rinse it out with water therefore increasing the proportion of water in the solution. The conclusion to this was that the concentration of hydrochloric acid had decreases, this had lead to the reacting particles to collide less frequently thus reducing the speed of the reaction. This may have been a reason for some plots on the graphs not to be exactly on the best-fit line.I could have improved this situation by using dozens of conical flasks one for every trial or even just blow dry the used conical flask. The experiment was held at room temperature so there was not an exact fixed temperature that had surrounded the solution. The room temperature must have varied time-to-time this may have been caused by body heat lost to the surroundings by students in the class. This would interfere with the reaction giving the particles more kinetic energy therefore altering the hydrogen released. I could improve this situation by carrying out the experiment in a class with very few students, this would decrease body heat lost to the surroundings. All this said I still think very strongly that all my results are reliable and accurate enough as there were no anomalous points on either of my graphs as a result giving me a successful conclusion to rates of reaction. All my evidence that I had obtained from my experiment are accurate for instance my tables and graphs. I had recorded all the relevant information that I needed from my experiment onto a labelled table, which then I had created my graphs from. All my graphs approve that my evidence are accurate because neither of the graphs have an anomalous point even though some plots are slightly off the best fit line. So my evidence is sufficient to support the conclusion to this investigation. I would extend my investigation by carrying out more concentrations of HCl and maybe using other chemicals such as sodium thiosulphate to contrast the rate of reaction between the two. This would let me know how different chemicals influence the rate of reaction and this can also help me to compare the results, which would give me a far better conclusion. In order for this to happen I would have to keep everything constant for both the chemicals like the temperature and the amount of Mg ribbon. The exothermic reaction had affected the outcome of the reaction causing more collisions therefore making the results less accurate. If I placed the conical flask in a temperature controlled container it would improve the accuracy of gaining better results. If I had to repeat this experiment again I would perform it with the Burette method because I have found out that this method guaranties more reliable and accurate results so I would gain more precise graphs.

You May Also Find These Documents Helpful

  • Powerful Essays

    During this experiment, acids of different concentration are utilized, and the different reaction rates calculated. When the reactant’s concentration increases, there are more atoms per space for a collision to occur. A prediction for the effect of concentration on reaction rate would be that the higher the concentration of the reaction, the faster the reaction time. As the temperature of the reaction rate increases, the molecules will move faster, also resulting in more collisions and perhaps a faster reaction rate.…

    • 2334 Words
    • 8 Pages
    Powerful Essays
  • Satisfactory Essays

    Ilab Chemistry Lab

    • 451 Words
    • 2 Pages

    In order to measure the atomic weight of magnesium after it is consumed, it has to be mixed with hydrochloric acid. Once it has consumed it will produce hydrogen gas, which will be trapped and measured. This means that the atomic weight of magnesium will result from separating the hydrogen gas from the acid in the magnesium. The chemical equation mentioned in the introduction indicates that one mole of hydrogen gas is produced for every mole of magnesium that reacts. In this lab, there is a 1:1 ratio between the number of moles of hydrogen gas evolved and the number of moles of magnesium consumed in the reaction. Therefore, the number of moles of hydrogen gas evolved is equal to the number of moles of magnesium consumed. The atomic weight of magnesium is equal to the weight of magnesium consumed per moles of hydrogen gas evolved.…

    • 451 Words
    • 2 Pages
    Satisfactory Essays
  • Satisfactory Essays

    During my observation I noticed that when 10mg of magnesium metal was added to the beaker a shaded area appeared on the bottom of the beaker. When the bubbles stopped and the shaded area in the beaker disappeared it showed that the magnesium has been consumed.…

    • 286 Words
    • 2 Pages
    Satisfactory Essays
  • Satisfactory Essays

    4.05 data observation

    • 306 Words
    • 2 Pages

    As the magnesium comes in contact with the CO2 it creates a bright burning light…

    • 306 Words
    • 2 Pages
    Satisfactory Essays
  • Good Essays

    An investigation to show how the rate of reaction between hydrochloric acid and sodium thiosulphate is affected by the concentration of the acid…

    • 1036 Words
    • 5 Pages
    Good Essays
  • Good Essays

    Molar Volume Lab

    • 736 Words
    • 3 Pages

    In this lab, a magnesium ribbon and HCl are combined in a gas measuring tube. When they are combined they form magnesium chloride and Hydrogen gas. The molar ratio between Mg reacted and H2 produced a 1:1. Thus the number of moles of H2 can be determined if the number of moles of Mg is found. The experimental volume of H2 is found in the experiment and by using the gas laws of both Boyle and Charles. The volume of H2 can be determined…

    • 736 Words
    • 3 Pages
    Good Essays
  • Good Essays

    This can be demonstrated by measuring the hydrogen gas evolved by performing a chemical experiment when hydrochloric acid reacts with the magnesium. The formulated reaction includes; Mg + 2HCl → H2 + Mg2+(aq) + 2Cl- (aq)…

    • 370 Words
    • 2 Pages
    Good Essays
  • Good Essays

    Magnesium Lab

    • 797 Words
    • 4 Pages

    Controlled - Size of Mg piece, amount of HCl in test tube, room temperature, method of agitation.…

    • 797 Words
    • 4 Pages
    Good Essays
  • Good Essays

    Kinetic Reaction Lab

    • 719 Words
    • 3 Pages

    One application of the study of kinetics can be applied to the determination of the rate of a chemical reaction involving a certain selection of chemicals (FD&C Blue #1 and sodium hypochlorite). The purpose of the proceeding experiment is to make such a determination, as well as determining the rate law for the reaction by establishing the rate constant and concentrations and reactions orders of the chemicals.…

    • 719 Words
    • 3 Pages
    Good Essays
  • Good Essays

    Formal Lab Report

    • 981 Words
    • 4 Pages

    Aim: In this experiment we are going to see the effects of using three different concentrations of HCl when added to Magnesium metal on the rate of reaction.…

    • 981 Words
    • 4 Pages
    Good Essays
  • Powerful Essays

    The purpose of this lab is to be able to observe the reaction rates of different chemical substances, by looking at which substance is the fastest reactant. This is what chemical kinetics is. Reaction rate is the change in the concentration of a reactant or product in a chemical reaction per unit time. In this lab the requirement was to be able to calculate each Average reaction rate which is the change in reactant or product concentration at a given time interval. Some equations that were required for this lab is the basic equation to determine the moles of magnesium for each piece in the lab. This formula is n=m/M. This is moles, which is equal to mass over Molar mass.…

    • 837 Words
    • 4 Pages
    Powerful Essays
  • Good Essays

    Chemical Reaction Lab

    • 663 Words
    • 3 Pages

    To a 150-mL, 0.1 gram of sodium hydrogen (solid) was measured and added. Drop wise, 1 mL of 1.0 M HCl was slowly added. The characteristics of the reaction were recorded.…

    • 663 Words
    • 3 Pages
    Good Essays
  • Powerful Essays

    Reactants Lab

    • 1408 Words
    • 6 Pages

    This experiment was done to determine the effects of the nature of the reactants, concentration, temperature, surface area and catalyst on the rate of chemical reactions. The nature of the reactants implies a difference if the reactants are aqueous or organic, acidic or basic or if they occur in the same phase or not. Acid-base reactions, formation of salts, and exchange of ions are fast reactions while reactions in which large molecules are formed or broken apart are usually slow. Generally, the rate of reaction is directly proportional to the concentration of the reactants, as well as to the temperature. Greater surface areas and addition of catalysts also increase the rate of chemical reactions.…

    • 1408 Words
    • 6 Pages
    Powerful Essays
  • Satisfactory Essays

    The volume of hydrochloric acid should be kept constant. Different volume of HCl reacting with calcium carbonate will result in fewer or more collisions between particles, so the calculated rate will…

    • 355 Words
    • 2 Pages
    Satisfactory Essays
  • Good Essays

    Magnesium Volume Lab

    • 582 Words
    • 3 Pages

    The Magnesium was silvery-white, lustrous and relatively flexible before being placed in the burette. Whilst reacting with the hydrochloric acid, it dissolved and bubbles were visible. The hydrochloric acid slowly diffused downwards.…

    • 582 Words
    • 3 Pages
    Good Essays