In this study, nickel-titanium surfaces are coated with phenolic thin films of tannic acid and pyrogallol with the purpose of studying their corrosion resistance in physiological environments. Three tests are performed: the open circuit potential test, potentiodynamic polarisation and potentiostatic electrochemical impedance spectroscopy. Polarisation measurements are scrutinized in order to gain knowledge concerning the kinetics of the cathodic and anodic reactions, while the open circuit and impedance spectroscopy help to study the electrolyte-surficial interactions. It is found that coating nitinol with polyphenols reduces the metal, resulting in depletion of the native oxide layer and thus a decrease of corrosion resistance. Pyrogallol …show more content…
Inside the living body, implanted metals are primarily exposed to highly oxygenated body fluids containing inorganic ions (chloride, carbonate, calcium, etc.), proteins, lipids, amino acids and cells that assemble around the implanted metal [1]. Biomaterials devices made of smart metals such as the equiatomic binary alloy, nickel-titanium (commonly known as nitinol), may corrode when in contact with body fluids that act as a conducting electrolyte solution favourable for electrochemical corrosion. Nitinol shape memory alloys typically are covered by a naturally formed thin adherent oxide layer of titanium known as a passive film. This film is very stable and nitinol alloys are resistant to many forms of corrosive attacks; however, this passive film can be attacked by acidic solutions containing chloride [3]. In addition, the oxides formed on the nitinol surface always contain a certain fraction of nickel. Contrary to pure titanium and Ti4Al6V medical alloys, which easily repassivate after surface damage, the nitinol oxides have a lower self-healing ability in scratch tests, a lower resistance to localized corrosion [4, 5].
In previous studies, electrochemical tests have been used to evaluate the corrosion resistance of nitinol alloys in various physiological environments [6-16]. The correlation of the results from these studies in regards to the corrosion resistance
…show more content…
All these measurements were performed on a Gamry potentiostat/galvanostat Zero-resistance Ammeter Reference 3000 (Gamry Instruments Inc., Warminster, PA), and data were analysed with Gamry Echem 7.03 software (Gamry Instruments Inc., Warminster, PA) and EIS data with Zview 3.4d ( Scribner associates, Inc., NC). An OCP was continuously monitored for 24 h, and the potential was recorded as a function of measuring time every 0.5 s prior potentiodynamic polarisation measurements performed in the potential range from -1000 to 1600 m V with a scanning rate of 0.1667 m V s-1. The electrode was immersed in the test solution for 60 minutes prior each test in order to stabilise the system temperature [22]. EIS tests were carried out at OCP with 10 mV of signal amplitude and a frequency interval from 0.01 Hz to 50 kHz. EIS measurements were performed subsequently after 1, 3, 6, 12 and 24 h prior each

You May Also Find These Documents Helpful

  • Good Essays

    Nt1310 Unit 1 Lab Report

    • 609 Words
    • 3 Pages

    Visualize your radioactively labeled target sequence. If you used a radiolabeled 32P probe, then you would visualize by autoradiograph.…

    • 609 Words
    • 3 Pages
    Good Essays
  • Satisfactory Essays

    Adjust cell suspension volume with media so that between 15 to 100 L of cells are used for each well/dish. This small plating volume ensures that there is even cell distribution and that growth factors, drugs, or substrates in the medium are not diluted.…

    • 237 Words
    • 1 Page
    Satisfactory Essays
  • Satisfactory Essays

    Nt1310 Unit 3 Lab Report

    • 405 Words
    • 2 Pages

    . Na+ and K+. K+ was more concentrated inside the cell while Na+ was more concentrated outside the cell.…

    • 405 Words
    • 2 Pages
    Satisfactory Essays
  • Good Essays

    Nt1310 Unit 1 Lab Report

    • 2556 Words
    • 11 Pages

    Lab #11 Software Defined Radio (SDR) I. Experimental Procedure Equipment List Universal Software Radio Peripheral (USRP) with Flex900 Radio Spectrum analyzer (Agilent E4411 or equivalent) PC with Matlab/Simulink R2011B CAT 6 Ethernet cable SMA(male)-to-BNC Adapter (for spectrum analyzer) 915 MHz Antenna (qty 2) A. INSTRUMENT CONNECTIONS: Connect the antenna to the SMA connector labeled RF1 port on the front of the USRP. Connect another antenna to the spectrum analyzer. Power the USRP with a 6v/3A power adapter. B. CONFIGURE PC: a. Connect the CAT6 cable between the PC and the GB Ethernet port of the USRP. b. Manually set the PC’s Ethernet port IP address under the same subnet mask as the…

    • 2556 Words
    • 11 Pages
    Good Essays
  • Satisfactory Essays

    Nt1310 Unit 1 Lab Report

    • 344 Words
    • 2 Pages

    In experiment 2 our main objective was to understand the analysis of resistors, inductors and capacitors in a sine wave circuit. we measured the impedance of the inductor and capacitor using a current sensing resistor. Inductive reactance is the opposition to the flow of current, and capacitive reactance is the opposition to the flow of charge. The tools we used for this experiment a pair of resistors, an inductor, a capacitor, dual channel oscilloscope, audio oscillator, and a digital multimeter. Using the oscilloscope we where able to measure the devises easily. Using the audio oscillator too change our setting to the wright context we measured the Vrms of our circuits. Using the Vrms we were able to find all of our unknowns using equations and our knowledge of circuit analysis.…

    • 344 Words
    • 2 Pages
    Satisfactory Essays
  • Good Essays

    This assignment entailed the task of investigation into the a) Conditions under which corrosion is accelerated, and b) Methods of preventing corrosion. Two experiments were implemented to answer these questions and hence reach a definate conclusion.First off let's look at the background of corrosion and the way in which it occurs.The first hypothesis to answer was, 'What affect does water temperature have on the rate of corrosion of iron in sea water?' The assumed answer was that ' As temperature decreases, the rate of corrosion will decrease.' Secondly, 'Which sacraficial anode would protect and shield the Iron, resulting in a decrease in corrosion levels, within salt water?' The hypothesised answer was that the more active a metal then iron is ,the greater protection it would provide.'…

    • 366 Words
    • 2 Pages
    Good Essays
  • Better Essays

    Titanium is a transition metal that was discovered in the year 1791 by an English pastor named William Gregor. The discovery was made when Gregor was by a Stream in the parish of Mannacan in Cornwall, England and found black magnetic sand. When Gregor analyzed this sand, he found out it was made up of the oxides of iron and an undefined and yet undiscovered metal. He named this metal Manaccanite, after the parish of Mannacan.…

    • 757 Words
    • 4 Pages
    Better Essays
  • Better Essays

    The independent variables for this investigation are the types of solutions and the types of metals used. The three types of metals are Copper (II), Magnesium and Nickel and the three types of solutions being used for reactivity test are lead (II) nitrate (0.1mol/L) , zinc nitrate (0.1mol/L) and iron (III) nitrate (0.1mol/L). A total of nice trials are going to be carried out with different combinations of a metal and a solution. The combinations include copper (II) with lead (II) nitrate, copper (II) with zinc nitrate, copper (II) with iron (III) nitrate, magnesium with lead (II) nitrate, magnesium with zinc nitrate, magnesium with iron (III) nitrate, nickel with lead (II) nitrate, lead with zinc nitrate and lead with iron (III) nitrate.…

    • 2401 Words
    • 10 Pages
    Better Essays
  • Powerful Essays

    The corrosion-retarding effect of the protective layer is produced by the particular distribution and concentration of alloying elements in it. The layer protecting the surface develops and regenerates continuously when subjected to the influence of the weather. In other words, the steel is allowed to rust in order to form the 'protective' coating.…

    • 609 Words
    • 3 Pages
    Powerful Essays
  • Good Essays

    Nomi Nickel Analysis

    • 928 Words
    • 4 Pages

    The Mennonite community of East Village has separated themselves from the outside world to keep their traditions and beliefs strict for its members and keep outsiders from interfering. Miriam Toews presents Nomi Nickel as the narrator to view the community of East Village from the perspective of an insider who recognizes issues and examines them. Toews’s writing, specifically from Nomi’s point of view, allows the audience to examine the culture from the insider’s standpoint.…

    • 928 Words
    • 4 Pages
    Good Essays
  • Good Essays

    Fireworks

    • 1040 Words
    • 5 Pages

    Oxidantii utilizati cel mai frecvent sunt nitratii, componenta majora a pulberii negre. Nitratii sunt compusi din ioni nitrati (NO3-) cu ioni metalici. Oxidantul cel mai comun este azotatul de potasiu care se ddescompune in oxid de potasiu, azot, oxigen/…

    • 1040 Words
    • 5 Pages
    Good Essays
  • Good Essays

    Copper Corrosion

    • 669 Words
    • 3 Pages

    The Effect of pH Level of a Liquid on the Rate of Corrosion of Copper wire…

    • 669 Words
    • 3 Pages
    Good Essays
  • Good Essays

    Electrolysis is the electrochemical process where a direct current (DC) drives a non-spontaneous chemical reaction, assisting with the process of chemical decomposition. The electrolytic process requires an:…

    • 5889 Words
    • 24 Pages
    Good Essays
  • Powerful Essays

    Iron, a common type of metal in the form of alloy steel which is widely used…

    • 2400 Words
    • 13 Pages
    Powerful Essays
  • Good Essays

    Corrosion Control

    • 4543 Words
    • 19 Pages

    Regardless of the type of corrosion or the metal involved, corrosion treatment requires three basic steps:…

    • 4543 Words
    • 19 Pages
    Good Essays