Neural Network Based Transformer Differential Protection
NEURAL NETWORK BASED TRANSFORMER DIFFERENTIAL PROTECTION
Abstract: The role of a differential relay for power transformer is to trip during fault condition and blocks the tripping during inrush, overexcitation, CT saturation conditions of the power transformer. Conventional harmonic restrained relay may mal operate due to the presence of the second and fifth harmonic during internal faults because of non-linear loads and capacitance in the transmission lines. This project presents a technique for classifying transient phenomena in power transformers for differential protection. Discrimination among different operating conditions (i.e., normal, inrush, overexcitation, CT saturation) and internal faults of the power transformer is achieved by differential relay using the algorithm based on wavelet transform with Neural Network. The wavelet transform is a powerful tool in the analysis of the power transformer transient phenomena because of its ability to extract information from the transient signals simultaneously in both the time and frequency domain. Neural network is used because of its self-learning and highly nonlinear mapping capability. Keywords – Wavelet Transform, back propagation neural netwok, transformer differential protection. I.Introduction Differential protection is the primary protection for larger power transformers. It contains the operation by all types of internal faults, and blocks the operations of the transformer by inrush, overexcitation and external faults. Since a magnetizing inrush current generally contains a large second harmonic component in comparison to an internal fault, conventional transformer protection systems are designed to restrain during inrush transient phenomenon by sensing this large second harmonic. However, the second harmonic component may also be generated during internal faults in the power transformer, due to CT saturation or the presence of a shunt capacitor or the distributive capacitance in a long EHV



References: [1] Fahrudin Mekic, Ramsis Girgis, Zoran Gajic, Ed teNyenhuis, “Power Transformer Characteristics and Their Effect on Protective Relays”, 33rd Western Protective Relay Conference, October 17-19, 2006 [2] P. Bastard, M. Meunier, and H. Regal, "Neural-network-based algorithm for power transformer differential relays," IEE Proceedings on Generation, Transmission and Distribution, vol. 142, no. 4, pp. 386-392, July 1995. [3] G. Perez, A. J. Flechsig, J. L. Meador, and Z. Obradovic, "Training an artificial neural network to discriminate between magnetizing inrush and internal fault," IEEE Transactions on Power Delivery, vol. 9, no. 1, pp.434-441, January 1994. [4] P. B. Grcar and D. Dolinar, "Improved operation of power transformer protection using artificial neural network," IEEE Transactions on Power Delivery, vol. 12, no. 3, pp. 1128-1136, July 1997. [5] M. R. Zaman and M. A. Rahman, "Experimental testing of the artificial neural network based protection of power transformers," IEEE Transactions on Power Delivery, vol. 13, no. 2, pp. 510-517, Apr. 1998. [6] Chien-hsing lee, yaw-juen wang, wenliang huang, “A Literature Survey of Wavelets in Power Engineering Applications”, Proc. Natl. Sci. Counc. ROC(A), Vol. 24, No. 4, 2000. pp. 249-258. [7] M. G. Morante and D. W. Nocoletti, "A wavelet - based differential transformer protection," IEEE Transactions on Power Delivery, vol. 14, no. 4, pp. 1351-1358, October 1999. [8] O. A. S. Youssef, "A wavelet-base technique for discrimination between faults and magnetizing inrush currents in transformers," IEEE Transactions on Power Delivery, vol. 18, no. 1, pp. 170-176, January 2003. [9] A R Sedighi, M.R. Haghifam, " Detection of inrush current in distribution transformer using wavelet transform", Electrical Power and Energy Systems 27 (2005), pp. 361-370 Elsevier [10] Y. Zhang, X. Ding, Y. Liu, and P. J. Griffin, "An artificial neural network approach to transformer fault diagnosis," IEEE Transactions on Power Delivery, vol. 11, no. 4, pp. 1836-1841, October 1996. [11] Atthapol Ngaopitakkul and Anantawat Kunakorn, "Internal Fault Classification in Transformer Windings using Combination of Discrete Wavelet Transforms and Back-propagation Neural Networks", International Journal of Control, Automation and Systems, vol. 4, no. 3, pp. 365-371, June 2006

You May Also Find These Documents Helpful

  • Better Essays

    Iron- Transformers are used widely in consumer electronic products to step down the supply voltage to a level where it will be suitable for the low voltage circuits they contain. In these kinds of applications the transformer could also act as a key safety component that electrically isolates the end user from direct contact with the extremely dangerous supply…

    • 1562 Words
    • 7 Pages
    Better Essays
  • Satisfactory Essays

    ELECTRICAL CIRCUITS 1 ELECTRICAL CIRCUITS 2 ELECTRICAL MACHINES-1 ADVANCE MACRO ECONOMICS POWER SYSTEM PROTECTION STATISTICS FOR SOCIAL SCIENCE INTERNATIONAL LOGISTICS AND SUPPLY CHAIN MANAGEMENT STRATEGIC MANAGEMENT BANK FUND MANAGEMENT SOCIETY & THE ARCH. OF BENGAL BUSINESS COMMUNICATIONS…

    • 1161 Words
    • 5 Pages
    Satisfactory Essays
  • Good Essays

    This is because there are no air gaps available for that. The conventional transformers are constructed mostly using two individual parts. When these two parts are joined, small air gasps are most likely to be formed. The stray magnetic field will arise around the air gaps formed. Due to the low magnetic stray field in the toroidal transformers, they are very useful when it comes to the critical applications such as medical equipment.…

    • 811 Words
    • 4 Pages
    Good Essays
  • Best Essays

    A power transformer is an electrical machine used in reticulation/distribution networks which steps voltage up or down (according to network requirements) for the efficient supply of electricity to various connection points. The transformers vary in size and capacity – the bigger the capacity of transformation, the bigger the size. Manufacturing a transformer requires specialized machinery as well as hand craft – the bigger the size of a transformer, the more the hand craft. Transformer parts cannot be discretely tested, all parts (including accessories) have to be assembled into a complete transformer machine before testing its performance – this is mentioned to highlight the due diligence required. Manufacturing of large transformers is traditionally done in European countries and therefore delivery means moving the transformer from a manufacturing factory in Europe to a customer base in South Africa. It involves various mode of transportation, namely: railway, sea and road. From factory, the transformer is crane lifted onto a rail bed and moved to a harbour where it is hoisted onto a ship and transported to South Africa. From a South African harbour, a transformer is placed onto a low bed ‘abnormal’ vehicle and…

    • 2598 Words
    • 11 Pages
    Best Essays
  • Powerful Essays

    Oil sampling analysis is a useful, predictive, maintenance tool for determining transformer health. DGA is identified as one of the sufficient method of oil sampling in evaluating transformer health. The breakdown of electrical insulating material inside the transformer generates gases within the transformer. The identity of gases being generated is useful in any preventive method maintenance program. DGA method involves oil sampling method and testing the sample to measure the concentration of the dissolved gases.…

    • 1947 Words
    • 8 Pages
    Powerful Essays
  • Good Essays

    2009- Date South Pars Gas Complex, Phase 2 & 3, Assaluyeh, Iran. I worked as a Utility Supervisor in the fields below;…

    • 479 Words
    • 2 Pages
    Good Essays
  • Good Essays

    Electrical Substation

    • 4251 Words
    • 18 Pages

    If a load is connected to the secondary, an electric current will flow in the secondary winding and electrical energy will be transferred from the primary circuit through the transformer to the load. In an ideal transformer, the induced voltage in the secondary winding (Vs) is in proportion to the primary…

    • 4251 Words
    • 18 Pages
    Good Essays
  • Good Essays

    frequencies have been observed 25 and 75Hz with their corresponding amplitudes in dB respectively. It may also be understand from Table.I. Therefore, due to the non-intrusive nature of the wavefroms; we may clearly state that an competent stator inter-turn fault detection has been done in the steady state no-load…

    • 848 Words
    • 4 Pages
    Good Essays
  • Good Essays

    Mr Google Fgt

    • 31177 Words
    • 125 Pages

    Pignari S.A. and Orlandi A. (2003). ”Long-cable effects on conducted emissions levels”, IEEE Transactions on Electromagnetic Compability, vol. 45, no. 1, pp. 43-54 Popovic L.M. (2007). ”Ground fault current distribution in stations supplied by a line composed of a cable and an overhead section”, European Transactions on Electrical Power, vol. 17, no. 3, pp. 201-218 Roberts J., Altuve H.J. and Hou D. (2001). Review of ground fault protection methods for grounded, ungrounded and compensated distribution systems, Schweitzer Engineering Laboratories, Inc. Pullman, USA Tziouvaras D.A. (2006). ”Protection of high-voltage AC cables”, 2006 Power Systems Conference: Advanced Metering, Protection, Control, Communication, and Distributed Resources (IEEE), pp 316-328 Transfix (2005). “Transfix test report Ecobloc transformer”. Available: ECOBLOC-SVEA Drift och Instruktionsmanual broschyr, Helmer Verken, Göteborg (2006) or (Akke 2006) Zamora I., Mazón A.J., Eguia P., Valverde V. and Vicente R. (2004). ”Influence of resonant coil tuning in the fault current magnitude”, th Proceedings on the 12 IEEE Mediterranean Electro technical conference, pp. 979 -982…

    • 31177 Words
    • 125 Pages
    Good Essays
  • Powerful Essays

    Power System Stabilizers

    • 3442 Words
    • 14 Pages

    Power System Stabilizers Term Project Control of Electric Motors ECE 6670 Gary S Lear December 16, 2013 Table of Contents I. Introduction ........................................................................................................ 1 II. Simulation of Linearized State-Space Model.................................................... 2 A. Open-Loop Simulation ............................................................................ 2 B. PI Automatic Voltage Regulator ............................................................. 5 C. Single-Input Power System Stabilizer ................................................... 7 D. Dual-Input Power System Stabilizer......................................................…

    • 3442 Words
    • 14 Pages
    Powerful Essays
  • Powerful Essays

    Motor Starter Comparison

    • 3952 Words
    • 16 Pages

    Abstract—This paper presents a comparison between the Direct-On-Line (D.O.L.), Star-Delta, and Auto-transformer induction motor starting method in terms of power quality. The purpose of this research is to find out the most reliable and practical starting method which has the less power quality problems. These three basic starting methods which differ in their respective wiring connection are the most applicable and widely-used starting method in the industrial area due to its economic reasons. This research is done by analyzing the existed power quality events during the motor starting by using the Fluke Power Quality Analyzer to capture the waveforms of the events. After the experiments, the three different starting method are being compared to conclude the most suitable and applicable starting method which causes the least severe power quality events.…

    • 3952 Words
    • 16 Pages
    Powerful Essays
  • Powerful Essays

    Upfc

    • 2393 Words
    • 10 Pages

    ABSTRACT: This is a new technique for the protection of transmission systems by using the global positioning system (GPS) and fault generated transients. In this scheme the relay contains a fault transient detection system together with a communication unit, which is connected to the power line through the high voltage coupling capacitors of the CVT. Relays are installed at each bus bar in a transmission network. These detect the fault generated high frequency voltage transient signals and record the time instant corresponding to when the initial travelling wave generated by the fault arrives at the bus bar. The decision to trip is based on the components as they propagate through the system. The communication unit is used to transmit and receive coded digital signals of the local information to and from the associated relays in the system .At each substation relay determine the location of the fault by comparing the GPS time stay measured locally with those received from the adjacent substations, extensive simulation studies presented here demonstrate feasibility of the scheme.…

    • 2393 Words
    • 10 Pages
    Powerful Essays
  • Good Essays

    In most of the cases failures of transformer is due to the failure of OLTC. Hence the OLTC becomes the very important part of the transformer. Its failure can result in unavailability of the power transformer or total loss of the power transformer. The sudden failures of power transformer not only include the replacement cost but, safety, environmental issues and, in case a spare transformer is not directly available additional cost for not delivered power and penalty cost should also be considered. So it is become necessary to get the information about the condition of the OLTC. Conventionally maintenance of any equipment is predefined with fixed time interval by its manufacturer or supplier. Now a Modern tendency is to perform condition based rather than time based maintenance. It can reduce the maintenance cost, extend the service life of equipment and prevent possible catastrophic failure. In condition based maintenance one need to know the condition of the tap changer to determine when and what maintenance is…

    • 1218 Words
    • 5 Pages
    Good Essays
  • Good Essays

    Types Of Faults

    • 1870 Words
    • 8 Pages

    Design of systems to detect and interrupt power system faults is the main objective of power system protection.…

    • 1870 Words
    • 8 Pages
    Good Essays
  • Powerful Essays

    research paper

    • 2324 Words
    • 7 Pages

    The concept is to develop an approach based on wavelet transform for the evaluation of harmonic contents of power system waveforms. This new algorithmic approach can simultaneously identify all harmonics including integer, non-integer and sub-harmonics. This algorithm presents features that characterize the power quality disturbances from recorded voltage waveforms using wavelet transform. The discrete wavelet transform has been used to detect and analyze power quality disturbances. The disturbances of interest include sag, swell, outage and transient. Waveforms at strategic points can be obtained for analysis, which includes different power quality disturbances. The wavelet has been chosen to perform feature extraction. The outputs of the feature extraction are the wavelet coefficients representing the power quality disturbance signal. Wavelet coefficients at different levels reveal the time localizing information about the variation of the signal. A wavelet packet transform (WPT) method is introduced as a useful tool for detecting, classifying and quantifying the RMS of testing waveform and harmonic ratio value. The proposed approach can measure the distribution of the RMS of testing waveform with respect to individual frequency bands directly from the wavelet transform coefficients. The harmonic ratio value relative to basic frequency band can be calculated as well. The method is evaluated by its application to both analytical waveform and actual testing waveform data.…

    • 2324 Words
    • 7 Pages
    Powerful Essays

Related Topics