Modeling of a Cross Flow Heat Exchanger
Cross Flow Heat Exchanger Experiment

By
Andres Rodriguez

Abstract

The design project of the group was to create an experiment for Thermo/Fluids Laboratory. The experiment will help aide the students in relating pressure drop and heat transfer in a cross flow heat exchanger. The experiment consists of three cross flow heat exchangers (bare inline, bare staggered, and finned staggered) that will cool hot water with current fan in the Laboratory. Optimal flow rates, pressure and temperature drops were calculated for each case. Currently, a Lab View system is in process of being completed that will verify calculations made and give the students a better understanding of what is happening. So far there is one heat exchanger complete and two in processes. The heat exchanger will be operated in an ambient environment along with the attachment ducts.

Description of Work

This semester began with attempting to sort out the instruments purchased from Mamac Systems. Last semester's order was reviewed in greater detail and it was found that the instruments were incorrectly order due to many factors that involved an unclear website and an inexperienced student, which led to purchasing sensors without transducers that output a voltage. The majority of the equipment will have to be return and replace.

The drawings of the shell of the heat exchanger (shell of exchanger is the same for each configuration, and only vary in way the tubes are aligned) were sent out to Northridge's Plant Management and after a few meetings to clarify drawings the shell of the inline configuration was created. The shell was made without the through holes needed for the tubes, which was done by the group in the laboratory. Twenty eight 14" copper pipes were cut and solder to 90 degree elbows, which were modified to fit our arrangement. A ¼" of the face of the elbows were removed and connected with couplings made from the extra copper pipe left to another modified

You May Also Find These Documents Helpful

  • Good Essays

    Answers Lab06 BP

    • 1971 Words
    • 17 Pages

    1. Using the grouped sets of terms to the right of the diagram, correctly identify each trace, valve closings and openings, and…

    • 1971 Words
    • 17 Pages
    Good Essays
  • Good Essays

    Hvac

    • 673 Words
    • 3 Pages

    Shell and tube water cooled condensers Vertical shell and tube condensers Surface condenser Counter flow in condensers Cross flow in condensers Air cooled condensers Cooling Tower…

    • 673 Words
    • 3 Pages
    Good Essays
  • Good Essays

    While they require much more refrigerant and their tubing is more expensive per foot, a direct exchange loop is shorter than a closed water loop for a given capacity. A direct exchange system requires only 15 to 30% of the length of tubing and half the diameter of drilled holes, and the drilling…

    • 386 Words
    • 2 Pages
    Good Essays
  • Good Essays

    Heat Transfer Lab Report

    • 927 Words
    • 4 Pages

    • Understand and observe the concept of Heat Transfer, by measuring the temperature distribution for steady state conduction of energy through a specific efficient unit.…

    • 927 Words
    • 4 Pages
    Good Essays
  • Good Essays

    piping

    • 885 Words
    • 5 Pages

    the location of the final installation. As a general rule piping NPS 21⁄₂ (DN 65) and…

    • 885 Words
    • 5 Pages
    Good Essays
  • Better Essays

    References: Tutorial 1. Turbulent Flow and Heat Transfer in a mixing Transfer in a Mixing Elbow.…

    • 1355 Words
    • 6 Pages
    Better Essays
  • Satisfactory Essays

    The experiment was designed to investigate how sweating is effective on cooling you down. Four test tubes containing water that was all in different conditions of one being a normal test tube covered in newspaper, the same but was blown with a fan, a wet test tube covered in newspaper and the same one that was blown with a fan. For fifteen minutes, the temperature of the water in the test tube is measured every minute.…

    • 929 Words
    • 4 Pages
    Satisfactory Essays
  • Good Essays

    I have the idea of hammering 2 tubes in the ground, a slightly larger alluminum tube with a copper plumbing pipe inside, like this:…

    • 925 Words
    • 4 Pages
    Good Essays
  • Good Essays

    Seed Sampling

    • 2431 Words
    • 10 Pages

    slots in their walls so that when the tube is turned until the slots in the tube and…

    • 2431 Words
    • 10 Pages
    Good Essays
  • Powerful Essays

    Cross Flow Turbine

    • 14314 Words
    • 58 Pages

    Powering the Future: Model of a Hydroelectric Roller-Compacted Concrete Gravity Dam Steven Bhardwaj Scott Birney Michael Cullinan Faruq Siddiqui, Advisor Dept. of Engineering Swarthmore College May 3 2006 i Table of Contents Acknowledgements Abstract List of Tables List of Figures 1. Introduction 1.1 Goals 2. Project Specifications 2.1 Structural Design Constraints 2.2 Initial Dam Design Parameters 2.3 Turbine Selection 3. Design 3.1 Framing 3.2 Flooring and Walls 3.3 Bolts & Connections 3.4 Selection of RCC Compaction Method 3.5 RCC Consistency tests 3.6 Design of Concrete Forms 3.7 Structural Load Calculations 3.8 Dam Load Calculation 3.9 Water Load Calculation 3.10 Dynamic Load Calculation 3.11 Load Distribution 3.12 Dam Section Design 3.13 Design Loads 3.14 Loading Conditions 3.15 Gravity Dam Method of Analysis 3.16 Stability Considerations 3.17 Dam Design Calculations 3.18 Miscellaneous Appurtenances and Procedures 3.19 Water Flow Calculations 3.20 Crossflow Turbine Design Calculations 3.21 Frame Design 3.22 Plywood and Connection Design 3.23 Turbine Parameter Selection and Construction 3.24 Turbine Setup 3.25 Stepped Spillway 4.…

    • 14314 Words
    • 58 Pages
    Powerful Essays
  • Powerful Essays

    It seems that the conditions of heat absorption could be significantly improved by introducing changes to the exchanger design (e.g. extending the active surface, decreasing the gas flow speed). In order to estimate the maximum performance of the heat exchanger the following theoretical calculations have been made assuming constant temperatures of the exhaust gases on the exchanger outlet: 100, 150 and 200°C respectively.…

    • 2468 Words
    • 10 Pages
    Powerful Essays
  • Satisfactory Essays

    Nuclear Regulatory Commission (NRC) Generic Letter 89-13 requires periodic testing of all raw-water-cooled safety-related heat exchangers to ensure that the General Design Criteria of 10 CFR Part 50 are being met. Specifically, GL 89-13 addresses the requirements of GDC 44--Cooling Water, GDC 45--Inspection of Cooling Water System, and GDC 46--Testing of Cooling Water System. The heat exchangers associated with the Emergency Diesel Generators (EDG) at most nuclear power plants are raw-water cooled and safety-related, and therefore, fall under the requirements of GL 89-13. Whereas most of the larger safety-related heat exchangers can be tested and the resulting data reduced to an easily understood baseline value such as fouling factor, the EDG heat exchangers usually can not be tested in this manner due to lack of instrumentation, complex piping configurations, and automatic temperature-sensing flow control valves. The operational questions posed by GL 89-13 could be resolved readily if the EDG heat exchangers could be tested exactly at the conditions required or postulated by the most limiting accident scenario. Some of these parameters, such as kilowatt loading, can be easily attained; however, certain parameters such as the cooling water inlet temperature, or the external ambient air temperature may not be controllable. Such is the case with the Emergency Diesel Generator heat exchangers at Millstone Point Unit 1 (MP1). This paper details a test procedure that determined…

    • 5157 Words
    • 21 Pages
    Satisfactory Essays
  • Powerful Essays

    Natural circulation loop is the representative of primary heat transport system of a nuclear reactor. In a closed system without the use of pumps, circulation of fluids is generally maintained by thermal convection. This is why natural circulation is designed for the so-called Generation IV nuclear reactors, which like to employ passive safety and reliability. As a result, more and more attention has been given to natural circulation in the advanced reactor designs. A heat source and a heat sink connected by piping are the essential part of natural circulation loop. Here the heat sink is placed at higher elevation to promote natural circulation. The flow takes place due to the buoyancy force caused by density gradient resulting from temperature gradient. The natural circulation flow rate depends on the loop resistance and the temperature difference between the hot leg and the cold leg, as determined by the power level and the heat sink capacity.…

    • 2004 Words
    • 9 Pages
    Powerful Essays
  • Powerful Essays

    Cooling Tower Introduction

    • 3332 Words
    • 14 Pages

    * In the counter flow induced draft design, hot water enters at the top, while the air is introduced at the bottom and exits at the top. Both forced and induced draft fans are used.…

    • 3332 Words
    • 14 Pages
    Powerful Essays
  • Good Essays

    Heat Exchanger

    • 542 Words
    • 3 Pages

    A heat exchanger is a device that is used to transfer thermal energy (enthalpy) between two or more fluids, between a solid surface and a fluid, or between solid particulates and a fluid, at different temperatures and in thermal contact. In heat exchangers, there are usually no external heat and work interactions. Typical applications involve heating or cooling of a fluid stream of concern and evaporation or condensation of single- or multicomponent fluid streams. In a few heat exchangers, the fluids exchanging heat are in direct contact. In most heat exchangers, heat transfer between fluids takes place through a separating wall or into and out of a wall in a transient manner. In many heat exchangers,the fluids are separated by a heat transfer surface, and ideally they do not mix or leak. Such exchangers are referred to as direct transfer type, or simply recuperators. In contrast, exchangers in which there is intermittent heat exchange between the hot and cold fluids—via thermal energy storage and release through the exchanger surface or matrix—are referred to as indirect transfer type, or simply regenerators. Such exchangers usually have fluid leakage from one fluid stream to the other, due to pressure differences and matrix rotation/valve switching.…

    • 542 Words
    • 3 Pages
    Good Essays