Aim: Perform an experiment to determine the latent heat of fusion for milk.

Materials: Calorimeter

Celsius Thermometer

Platform balance

Kettle

Milk ice cubes

Stopwatch

Hot Water

Procedure: The copper cup was weighed and its mass was then recorded. The kettle was then used to boil water and this water was poured into the copper cup. The mass of the cup plus the hot water was calculated and recorded. The copper cup was then placed in the insulated container. The water's temperature was then recorded. The temperature of the milk ice was then recorded. The ice cub was then placed in the water. The thermometer was inserted and the temperature was taken at ten second intervals. This was done for two hundred seconds to allow the final temperature to be reached. The cup was removed from the insulated container and placed on the platform balance.

This procedure was repeated twice more to get data for a total of three trials.

Analysis: From the concept of thermal equilibrium the latent heat of fusion for milk was calculated from the data obtained from the experiment.

Q(lost) = Q(gained)

Q(gained) = Q(milk ice + milk) = mc(ice)∆T + mLf + mc(milk)∆T

Q(lost) = Q(water + cup) = m(cup)c(copper)∆T + m(water)c(water)∆T

(Working shown on following page)

From the latent heat of fusion calculated from the experiment it was observed that the avg. of the experiments produced an Lf of approximately 3.0X10^5J/kg. Following the comparison of the calculated Lf from the experiment with the actual value Lf of milk, which is 2.8X10^5j/kg, it is found that the data from the experiment is relatively accurate.

Therefore, it can be concluded that there are little to no inconsistencies with the data that was gathered from the experiment. The largest percentage error out of the three experiments was approximately 14% - A very good result considering the nature of the equipment used and experiment in general.

This experiment was susceptible to quite a few errors. The first of these is parallax error. The large number of measurements that were taken with the thermometer made parallax error a significant issue. In order to make sure this error was minimised, it was decided that the group would choose one member to take all measurements with the thermometer to ensure consistency.

The second error was the equipment used. If the calorimeter was open to error and large amounts of heat was lost to surroundings and/or vapour was able to escape causing errors in the final calculation because they are based on an ideal situation. A similar issue would result from faulty scales and thermometer. One such way to correct this issue is to ensure all equipment was accurate and in perfect working order before the experiment was conducted.

While the smallest percentage error was 0% (2.8X10^5/2.8X10^5*100%). This is hard to argue since "milk" is not a pure substance and therefore its Lf would vary. Thus, the Lf for the milk used in trial 1 would most likely have an Lf value that is different to the average of 2.8X10^5J/kg.

As a whole however, the data was not heavily affected by error as a relatively accurate Lf was calculated.

Conclusion: The data obtained from the experiment was able to give an approximate value for the latent heat of fusion for milk. From the trials, the most accurate trial presented the Lf of milk as 2.8X10^5J/kg. However, an analysis of error suggested that the error in this experiment was approximately 2.9%, suggesting that the actual latent heat of fusion for milk was closer to 2.88X10^5J/kg or 2.72X10^5J/kg. The temperature versus time data was an exponential decay model. Finally, the experiment was able to show the latent heat of fusion for milk with some amount of error.

This experiment was susceptible to quite a few errors. The first of these is parallax error. The large number of measurements that were taken with the thermometer made parallax error a significant issue. In order to make sure this error was minimised, it was decided that the group would choose one member to take all measurements with the thermometer to ensure consistency.

The second error was the equipment used. If the calorimeter was open to error and large amounts of heat was lost to surroundings and/or vapour was able to escape causing errors in the final calculation because they are based on an ideal situation. A similar issue would result from faulty scales and thermometer. One such way to correct this issue is to ensure all equipment was accurate and in perfect working order before the experiment was conducted.

While the smallest percentage error was 0% (2.8X10^5/2.8X10^5*100%). This is hard to argue since "milk" is not a pure substance and therefore its Lf would vary. Thus, the Lf for the milk used in trial 1 would most likely have an Lf value that is different to the average of 2.8X10^5J/kg.

As a whole however, the data was not heavily affected by error as a relatively accurate Lf was calculated.

Conclusion: The data obtained from the experiment was able to give an approximate value for the latent heat of fusion for milk. From the trials, the most accurate trial presented the Lf of milk as 2.8X10^5J/kg. However, an analysis of error suggested that the error in this experiment was approximately 2.9%, suggesting that the actual latent heat of fusion for milk was closer to 2.88X10^5J/kg or 2.72X10^5J/kg. The temperature versus time data was an exponential decay model. Finally, the experiment was able to show the latent heat of fusion for milk with some amount of error.

You May Also Find These Documents Helpful

  • Good Essays

    6.03 Calorimetry Lab

    • 992 Words
    • 4 Pages

    In the first process of the lab, you measure the mass of water transferred from a buret to a beaker, to determine the experimental mass of the water, and the volume of the water collected. We measured the temperature of the water so we could calculate the density of the water, which enabled us to calculate the actual volume of water, by using the density and the measured volume of water. To determine the percent error, we had to subtract the actual volume of water by the experimental volume of water transferred from the buret to the beaker, and then divided it by the actual volume and multiplied it by 100. In the second process, you perform the same steps you did for the buret, but instead, you use a 5.00mL or 10.00mL pipet. You repeated each…

    • 992 Words
    • 4 Pages
    Good Essays
  • Good Essays

    5. Continue to add 30-mL quantities of hot water until all of the ice is melted. Measure and record the temperature of the final…

    • 1576 Words
    • 7 Pages
    Good Essays
  • Good Essays

    Cold Pack Essay

    • 377 Words
    • 2 Pages

    In this experiment, a device that measures heat, a calorimeter, will be used. For this experiment, a calorimeter will be made with two nested Styrofoam cups, cardboard to cover the top as a lid, a thermometer, as well as about 25mL of water and about 7g of NH4¬NO3. The temperature of the solution will be closely monitored with the thermometer.…

    • 377 Words
    • 2 Pages
    Good Essays
  • Good Essays

    Caloric Content of Food

    • 623 Words
    • 3 Pages

    The first step in this experiment was to weigh and record an empty 100mL beaker. Then fill the beaker approximately halfway, weigh it and record the weight. Record the weight of the water in the beaker. Place a piece of aluminum foil on a table top. Place a wire burner stand with the beaker full of water in the center of the aluminum foil and place a candle next to the rack. Measure the weight of one marshmallow and the weight of one fork. Record both measurements. Then place the marshmallow on the fork measure and record the weight of the marshmallow and fork together. That weight should equal the measurements of the fork and marshmallow combined in the previous measurement. Measure and record the temperature of the water in Celsius and record it. Light a candle. Put the fork with the marshmallow over the candle flame. Remove the marshmallow from the flame right after it sets on fire and place it under the beaker of water. Hold it under the water until it is completely done burning. Make sure to stir the water frequently with the thermometer. When the marshmallow has burned down as much as possible, remove from under water and record the temp of the water. Then record the weight of the fork with leftover marshmallow on it. Subtract that measurement from the previous measurement of the fork with pre-burned marshmallow. Record the measurement of the marshmallow residue.…

    • 623 Words
    • 3 Pages
    Good Essays
  • Satisfactory Essays

    Chemistry 1 Lab Report

    • 580 Words
    • 3 Pages

    Conclusion: In this experiment we had to find the heat capacity of the calorimeter cup using two trials of hot and cold water. When we obtained the data after 10 minutes of recording 30 second intervals of the calorimeter cup temperature, we created a…

    • 580 Words
    • 3 Pages
    Satisfactory Essays
  • Satisfactory Essays

    Chem Lab

    • 286 Words
    • 2 Pages

    Measurements were relatively accurate and closely linked to quantitative values. When measurement was a little higher, value resulted a little higher. The Styrofoam for this experiment was necessary because it insulates leading to less energy loss to the surrounding of the system. Because there was a change in temperature from the initial and final results, there cannot be an assumption that there was no heat exchange with the surroundings. To improve accuracy of result from this experiment, a better calibration and calorimeter may be used to reduce the amount of heat absorbed during the process.…

    • 286 Words
    • 2 Pages
    Satisfactory Essays
  • Good Essays

    Name: Kensley Shelley|Date: 9-17-12| Exp 2: Laboratory Techniques & Measurements|Lab Section: 0000| Data Tables: Step 1: Length and Measurements Object Measured|Length in cm|Length in mm| Key|5.15 cm|51.5 mm| CD|12.0 cm|120.0 mm| Fork Spoon|18.05 cm 16.30 cm|180.5 mm 163.0 mm| Step 2: Warm Temperature Measurements Hot tap water temperature 49.50_˚C…

    • 1081 Words
    • 5 Pages
    Good Essays
  • Good Essays

    Microscale Lab

    • 709 Words
    • 3 Pages

    (e) Reliability of microscale experiments in general – use % errors in the automated pipets and your calibrated pipets for error…

    • 709 Words
    • 3 Pages
    Good Essays
  • Powerful Essays

    Day 2 of the experiment was performed on April 23, 2013. More testing was done on both apparatus’ in order to obtain enough data for error propagation.…

    • 6399 Words
    • 26 Pages
    Powerful Essays
  • Good Essays

    Ice Cream Lab

    • 462 Words
    • 2 Pages

    The purpose of this experiment is to learn and investigate chemical and physical properties of food, such as flavor, texture and consistency while producing ice cream.…

    • 462 Words
    • 2 Pages
    Good Essays
  • Good Essays

    Unfortunately time didn’t allow us to complete both parts of the experiment on our own and so we relied on the results of others in class. In terms of error, it gives plenty of opportunity for inconsistencies in the data. The inconsistencies could exist due to equipment, or understanding of the lab…

    • 274 Words
    • 2 Pages
    Good Essays
  • Good Essays

    This can been seen in the results tables where Methanol was added into a mixture, with Methanol being the majority; that the heat produced was greater than the theoretical calculated results. This experiment proves the hypothesis to be true in case where Methanol is the lower parent chain.…

    • 886 Words
    • 4 Pages
    Good Essays
  • Powerful Essays

    This lab report discusses an experiment to study thermodynamics and find ideal ionic compound to be used in hand warmer. Calorimetry experiment was conducted by dissolving three ionic compounds, CaCl2, Na2CO3, and NaCl, in distilled water to measure the enthalpy of solution.…

    • 1103 Words
    • 5 Pages
    Powerful Essays
  • Good Essays

    Phase Change Lab Report

    • 747 Words
    • 6 Pages

    Procedure: First a 400mL beaker was filled 2/3 full with ice. Next the time and temperature were recorded every minute for 18 minutes. All the data was recorded in a data table. Next the beaker was put on a hot plate and the temperature was taken and recorded every 30 seconds. Then the water was left to continue boiling for 5 more minutes and time and temperature were recorded every 30 seconds. Finally a graph of time and temperature was made.…

    • 747 Words
    • 6 Pages
    Good Essays
  • Good Essays

    Ice cream mix and other liquids are frozen by direct contact with carbon dioxide while…

    • 9294 Words
    • 38 Pages
    Good Essays

Related Topics