Intra Aortic Balloon Pump
Technology in Practice Part II:

Intra-Aortic Balloon Pump

Background of Technology

Before tThe intra-aortic balloon pump (IABP) became a successful piece of technology, it was first introduced by Harken in 1958 in hopes of treating left heart failure (IABPumpers, 2006). Harken thought that by removing a certain amount of blood from both femoral arteries during systole, and rapidly replacing it during diastole, he could augment the cardiac output and increase coronary perfusion. However, this pumping system led to extreme hemolysis and turbulence with failure to increase coronary blood flow (IABPumpers, 2006).

Soon after, Moulopoulus from Cleveland Clinic developed the first successful IABP in the 1960’s. This newly developed IABP was timed to inflate and deflate according to the phases of the cardiac cycle, and was first used in a clinical practice in 1968 by the Kantrowiz’s group (IABPumpers, 2006). Initially the placement of the IABP was done through surgical grafting due to the large size of the catheter, but as this technology improved through the years, the catheters became small enough to be placed non-surgically at patient’s bedside (IABPumpers, 2006). Now, with more than 70,000 balloon catheters inserted each year in the U.S, IABP therapy is known to be the mostas a common treatment for cardiogenic shock (Vales, Kanei, Ephrem, & Misra, 2011).

Purpose of Technology

The most important purpose of the IABP therapy is to increase cardiac output (Vales, Kanei, Ephrem, & Misra, 2011). As stated previously, tThe IABP is timed to inflate and deflate according to phases of the individual’s cardiac cycle (IABPumpers, 2006). Inflation of the balloon occurs at diastole, which displaces the blood from the aorta to the coronary arteries and the vital organs. Deflation occurs just before systole and left ventricular ejection. This deflation along with the blood displacement during diastole leads to decreased afterload and pressure in the



References: IABPumpers. (2006). History. Educating Nurses Online in IABP Therapy. Retrieved from http://www.iabpumpers.com/history.htm Insertion of intra-aortic balloon catheter (2005) Lewis, P., Ward, D., & Courtney, M. (2009). The intra-aortic balloon pump in heart failure management: implications for nursing practice. Australian Critical Care, 22(3), 125-131. doi:10.1016/j.aucc.2009.06.005 Nickson, C O 'Donovan, K. (2011). Intra-aortic balloon pump therapy. World Of Irish Nursing & Midwifery, 19(2), 37-39. Vales, L., Kanei., Ephrem, G., & Misra, D. (2011). Intra-aortic balloon pump use and outcomes with current therapies. Journal of Invasive Cardiology, 23(3), 116-119. Western Sydney Health Services. (2004). Intensive care evidence based practice: Intra aortic balloon pump Williams, L. (2005). Intra-aortic balloon pumping. Retrieved from http://intensivecare.hsnet.nsw.gov.au/five/doc/educationpackages/liverpool/liverpool_SDL_IABP.pdf

You May Also Find These Documents Helpful

  • Satisfactory Essays

    Imma Case Study

    • 431 Words
    • 2 Pages

    A sternal retractor was used and IMA was harvested and clamped with bulldog. The pericardium was continued to incise and pericardial edges was retracted with sutures to enhance exposure of the heart. The surgeon then identified the affected coronary artery, and coronary anastomotic site stabilizer was then used to reduce the movement of the beating heart and isolate the target coronary artery site for anastomosis (Fig.3). A fine mist of humidified CO2 gas was sprayed over the anastomotic site to clear the bleeding. Vessel loops, or silastic shunts was used to control bleeding. The distal anastomosis of the IMA with coronary artery was then performed side to side anastomoses with fine cardiovascular suture. Since IMA remained attached to the subclavian artery, no proximal aortic anastomosis required (Behny, 2006); the blood flow is restored as soon as the IMA anastomosis is established. If saphenous vein free graft was used during the off pump CABG, the distal end of the vein graft will be performed anastomosis first with the coronary artery, and then the other end of the vein graft will be sewn to the aorta either with the sutureless anastomosis device (Calafiore, et al., 2001) or hand sutured to aorta with the help of Hegar dilator loaded with the saphenous vein (Dikmengil, Ozeren, Aytacoglu, & Sucu, 2005) to minimize manipulation of the aorta . A drain will be…

    • 431 Words
    • 2 Pages
    Satisfactory Essays
  • Better Essays

    References: 1. American Heart Association. Advanced Cardiovascular Life Support (ACLS) Provider Manual. Dallas, TX: American Heart Association; 2011.…

    • 912 Words
    • 4 Pages
    Better Essays
  • Powerful Essays

    The ventricular assist device (VAD) is offered to patients in stage four heart failure, as a treatment option. A VAD is a mechanical pump that is used to aid the heart function and blood flow in individuals with a weekend heart (National Heart, 2012). With assistance from this device a patient’s blood is able to flow from a lower chamber of their heart into the rest of the body. Basically, it performs the job of a healthy heart. Currently, patients that are in need of a VAD are either hooked to a large machine or they carry a power source with them. With the third generation pump a patient has no need for the outside power source; everything is implanted inside of…

    • 1499 Words
    • 6 Pages
    Powerful Essays
  • Good Essays

    Spontaneous breathing in APRV results from diaphragm contraction, which should result in recruitment of dependent alveoli, consequently reducing shunt and improving oxygenation (Daoud et al, 2012. The spontaneous efforts also may enhance both recruitment and cardiac filling as compared with other controlled forms of support (Daoud et al, 2012). The long inflation phase also recruits slowly causing the alveoli to fill and the mean airway pressure to rise without increasing applied PEEP (APRV,…

    • 863 Words
    • 4 Pages
    Good Essays
  • Good Essays

    Grant Proposa

    • 906 Words
    • 4 Pages

    Stone GW, Marsalese D, Brodie BR, et al. A prospective, randomized evaluation of prophylactic intraaortic balloon counterpulsation in high-risk patients with acute myocardial infarction treated with primary angioplasty. J Am Coll Cardiol. 1997; 29: 1459–1467.…

    • 906 Words
    • 4 Pages
    Good Essays
  • Good Essays

    While researching for this paper, I became interested with Acute Myocardial Infarctions and just how quickly it can claim a life if not treated. While working at Bay Medical as a nurse intern in the ICU, I have seen numerous patients that have suffered from an AMI. Every year approximately 900,000 people in the US are diagnosed with AMI; among these, 225,000 will die, and an additional 125,000 will die without receiving any medical treatment (Comprehensive Review of Development for Core Measures, 2002). Treatment for AMI should begin immediately or as soon as possible. There…

    • 811 Words
    • 4 Pages
    Good Essays
  • Good Essays

    Types of Shock

    • 888 Words
    • 4 Pages

    Dugdale, D. (2012, June 22). Cardiogenic Shock. U.S National Library of Medicine. Retrieved November 23, 2013, from http://www.nlm.nih.gov/medlineplus/ency/article/000185.htm…

    • 888 Words
    • 4 Pages
    Good Essays
  • Good Essays

    One mechanical device that has assisted people with congestive heart failure is the ventricular assist device (VAD). The VAD is a small mechanical pump that is inserted into the ventricle and supplies a constant flow of blood in place of the ventricle’s pumping motion [Lemonick, 2000]. Although the VAD relieves the heart of much of its pumping duties, it does not cure the heart of its diseases, and therefore the heart continues to deteriorate and slowly fails. As a result, the ultimate solution in solving health problems caused by congestive heart failure may be the total artificial heart which is a mechanical device that permanently replaces the entire heart instead of just assisting the diseased heart like the VAD does.…

    • 571 Words
    • 3 Pages
    Good Essays
  • Good Essays

    When a patient’s heart is no longer able to pump a sufficient amount of blood around the body, they are referred to as having heart failure. The heart muscle has been damaged or overworked and is therefore unable to pump as effectively as before. Coronary heart disease is the most common cause of heart failure, cardiomyopathy and hypertension are also implicated (Peterson et al, 2002). Heart failure can present acutely or chronically. Chronic heart failure tends to worsen over time and symptoms, such as breathlessness and swollen ankles, will develop over weeks or months. An acute condition will present rapidly as a sudden worsening in those already with chronic heart failure or in those previously undiagnosed with cardiac…

    • 1123 Words
    • 5 Pages
    Good Essays
  • Good Essays

    Frank Staling Law

    • 637 Words
    • 3 Pages

    This allows the cardiac output to be synchronized with the venous return, arterial blood supply and humeral length[1] without depending upon external regulation to make alterations.…

    • 637 Words
    • 3 Pages
    Good Essays
  • Better Essays

    In the Vessel Resistance section for the Cardiovascular Dynamics experiment, two glass beakers, a tube connecting them and a pressure meter were used. The left beaker represented the heart, the right breaker represented the body and the tube was the artery. For the Pump Mechanics…

    • 2678 Words
    • 11 Pages
    Better Essays
  • Good Essays

    Principale of Marketing

    • 7385 Words
    • 30 Pages

    * Stint (a small spring that you can insert into your heart arteries, inorder to clear them). Johnson and Johnson invented the stint 20 years ago. First model; it enlarges the arteries, but then the body responses by attacking the stint because they recognize it as a foreigner. So, due to this response, the person with a stint usually has another heart attack, and the doctors then stick…

    • 7385 Words
    • 30 Pages
    Good Essays
  • Good Essays

    The Artificial Heart

    • 867 Words
    • 4 Pages

    The medical community realized that a completely implantable heart could avoid the mobility and infection problems caused by the Jarvik-7. In 1988, the National Institutes of Health began funding development of such hearts and was supporting such a program in 1991 totaling $6 million. Three years later, an electric and battery-powered implantable LVAD became available. In 1999, Charlie Chappis became the first patient ever released from a hospital with such a device.…

    • 867 Words
    • 4 Pages
    Good Essays
  • Better Essays

    Cpr for Infants

    • 1018 Words
    • 5 Pages

    References: Hazinski MF, Samson R, Schexnayder S. 2010 Handbook of Emergency Cardiovascular Care for Healthcare Providers. Dallas, Tx: American Heart Association; 2010.…

    • 1018 Words
    • 5 Pages
    Better Essays
  • Good Essays

    Blodtrykket er det tryk der er på blodet, når det bliver pumpet rundt i kroppen, det er et hurtigt udtryk for hjertets og kredsløbets tilstand. Det angives med to værdier: det systoliske blodtryk og det diastoliske blodtryk. Det systoliske blodtryk betegner den fase, hvor hjertet trækker sig sammen og pumper blod ud i kroppen, og det diastoliske, når hjertet slapper af og fyldes med blod. Når blodet pumpes ud af hjertet gennem aorta og arterierne, altså under systolen, opstår der et tryk på arterievæggene. Det er det, det systoliske blodtryk angiver. Det diastoliske angiver trykket på arterievæggene, men det er så…

    • 577 Words
    • 3 Pages
    Good Essays