How to Use a Homemade Seismograph
MATERIALS
1 10Hz 395 Ohm Oyo-Geospace Geophone (seismic energy sensor)
1 Metal Ground Strike Plate (seismic energy source earth coupling mechanism)
1 Heavy Piece of Metal (seismic energy source)
1 Analog Voltmeter (for measuring sensed seismic signal amplitudes) 1 Amplifier DC Offset Circuit (for amplifying seismic signals sensed by geophone) -1 experimental socket board -6 volt lantern battery -47k Ohm resistor -2.2k Ohm resistor - ICL 7660 integrated circuit
- IC 741 integrated circuit -1000 Ohm Potentiometer -10 microFarad capacitor (3)
-Jumper wires (10)
-4 mueller clip leads
METHODS
The first part of this process is to obtain all electrical and electronic components for the amplifier circuit. Then obtain the geophone and analog voltmeter. Then assemble the geophone amplifier circuit and test it to ensure that it works properly. Then electrically connect the geophone to the input of the geophone amplifier circuit, and electrically connect the output of the geophone amplifier circuit to the analog voltmeter.
Then bench test the assembled system, and initially adjust the DC bias of the geophone amplifier circuit during the bench test. Confirm that the system operates properly in a bench environment. Following bench testing of the system, perform field calibration and testing of the system. Determine a good outdoor field location for the acquisition of seismic data. Plant and couple the geophone into the ground. Measure and mark a series of pre-determined distances from the geophone along the ground surface (eg, 1 ft.-51 ft. in 5 ft. increments) to define a series of energy source stations. Place the strike plate at the 1 ft. location, and energize the seismic acquisition system. Drop the piece of metal from pre-determined height (eg, 3 ft.) onto the strike plate. Visually note and record maximum voltage sensed by analog voltmeter at this energy source station. Repeat these same steps at all subsequent energy

You May Also Find These Documents Helpful

  • Satisfactory Essays

    Record your answer from Lab Exercise #1, Step 1, Question 4. What is the distance in kilometers between the seismic station and the epicenter?…

    • 1340 Words
    • 6 Pages
    Satisfactory Essays
  • Powerful Essays

    Lm358 Unit 4

    • 2908 Words
    • 12 Pages

    Utilizing the circuit designs perfected for recently introduced Quad Operational Amplifiers, these dual operational amplifiers feature 1) low power drain, 2) a common mode input voltage range extending to ground/VEE, 3) single supply or split supply operation and 4) pinouts compatible with the popular MC1558 dual operational amplifier. The LM158 series is equivalent to one–half of an LM124. These amplifiers have several distinct advantages over standard operational amplifier types in single supply applications. They can operate at supply voltages as low as 3.0 V or as high as 32 V, with quiescent currents about one–fifth of those associated…

    • 2908 Words
    • 12 Pages
    Powerful Essays
  • Satisfactory Essays

    Soil Investigation: Prior to any foundation design or excavation work to take place, soil Geotechnical Investigation using process is carried out by a competent contractor, this to explore the surface and subsurface of each foundation. A CME-45B Truck Mounted Auger Drill is used retrieve soil samples, all samples are tested in an off-site laboratory. The truck operators are usually exposed to various types of…

    • 456 Words
    • 2 Pages
    Satisfactory Essays
  • Satisfactory Essays

    Complete University of Phoenix Material: Week Two Earthquakes Lab Report and University of Phoenix Material: Week Two Lab Report Worksheet by answering the following questions in Ch. 9 of Geoscience Laboratory : 9.1, 9.3, 9.5, 9.6, 9.10, 9.14, 9.17 (Longitude), and 9.20. Note that additional lab book questions and answers appear in the University of Phoenix Materials to assist in your completion of the lab.ds…

    • 431 Words
    • 2 Pages
    Satisfactory Essays
  • Better Essays

    eosc 114 full notes

    • 6069 Words
    • 25 Pages

    At least 3 earthquake recording stations are required to find the location of the earthquake epicenter. A single recording station can only calculate distance, but not direction; to cover all possibilities, a complete circle is drawn around that station. If only two earthquake recording stations are used, the circles will overlap at two points. Data from a third recording station will eliminate one of these points.…

    • 6069 Words
    • 25 Pages
    Better Essays
  • Good Essays

    Procedure: The motion detector was connected to the DIG/SONIC 1 channel of the interface and switched to Track. Then a single book was placed under one end of a 1-2m long track so that it formed a small angle with the horizontal. The two end points of the incline where adjusted, so that the distance, x, is between 1and 2cm. A motion detector was placed on top of the incline so that it was not closer than 0.15 m. In the Physics with…

    • 998 Words
    • 4 Pages
    Good Essays
  • Satisfactory Essays

    GLG 220 Week 4 DQs

    • 453 Words
    • 2 Pages

    Complete University of Phoenix Material: Week Two Earthquakes Lab Report and University of Phoenix Material: Week Two Lab Report Worksheet by answering the following questions in Ch. 9 of Geoscience Laboratory : 9.1, 9.3, 9.5, 9.6, 9.10, 9.14, 9.17 (Longitude), and 9.20. Note that additional lab book questions and answers appear in the University of Phoenix Materials to assist in your completion of the lab.ds…

    • 453 Words
    • 2 Pages
    Satisfactory Essays
  • Good Essays

    Read the Introduction to Earthquake Hazards and Human Risks lab in your lab manual and…

    • 1541 Words
    • 7 Pages
    Good Essays
  • Powerful Essays

    Chemistry Galvanic Cell

    • 1646 Words
    • 7 Pages

    6. Complete the circuit using wires and connected to the digital voltmeter and record voltage reading.…

    • 1646 Words
    • 7 Pages
    Powerful Essays
  • Satisfactory Essays

    Electric Charge

    • 342 Words
    • 2 Pages

    4) Use the tape measure to find and record the distance from the charge to the equipotential sensor.…

    • 342 Words
    • 2 Pages
    Satisfactory Essays
  • Good Essays

    Answer the lab questions for this week and summarize the lab experience using this form.…

    • 889 Words
    • 4 Pages
    Good Essays
  • Good Essays

    Ecg - Electrocardiogram

    • 568 Words
    • 3 Pages

    Step 3: Connect the leads to earth, CH1 negative and CH1 positive, on the Bio amp cable.…

    • 568 Words
    • 3 Pages
    Good Essays
  • Good Essays

    In middle school your child will be learning all about heat energy and temperature measurement, and will likely get to use a lab thermometer. This project will enable your child to construct a homemade thermometer that will compliment what he's learning about this instrument in school.…

    • 367 Words
    • 2 Pages
    Good Essays
  • Good Essays

    Once the piezo sensor is installed, the circuit obtained by wiring the sensor to an Arduino board as shown in Figure 10 is implemented. Upon successful implementation of the circuit, the program shown in pages 9 through 11 should be coded to the Arduino IDE for the calibration of the piezo sensor.…

    • 961 Words
    • 4 Pages
    Good Essays
  • Good Essays

    Semiconductors: IC1 - LM324 quad op-amp IC2 - 74LS76 J-K flip-flop IC3 - AT89C52 microcontroller IC4 - 7805 5V regulator T1, T2 - L14F1 npn phototransistor T3, T4 - 2N3904 npn transistor IR TX1, IR TX2 - IR transmitting LED BR1 - 1A bridge rectifier DIS1-DIS3 - LTS543 CC 7-segment display Resistors (all ¼-watt, ±5% carbon): R1, R2 - 68-ohm R3, R4 - 6.8-kilo-ohm R5, R6 - 100-ohm R7, R8, R10, R11 - 10-kilo-ohm R9 - 4.7-kilo-ohm R12-R32 - 220-ohm VR1, VR2 - 20-kilo-ohm preset RNW1 - 10-kilo-ohm resistor network Capacitors: C1, C2 C3, C4 C5 C6 C7 Miscellaneous: XTAL X1 S1 S2 - 0.2µF ceramic disk - 33pF ceramic disk - 10µF, 16V electrolytic - 470µF, 25V electrolytic - 0.1µF ceramic disk - 12MHz crystal - 230V primary to 7.5V, 250mA secondary transformer - Push-to-on switch - On/off switch…

    • 1522 Words
    • 7 Pages
    Good Essays