 INTRODUCTION

Power projects are essentially capital intensive. Not only they involve a highly initial cost which is around Rs. 4.5 to 5.0 crores per MW for coal-based plants but also huge operation cost. The running expenses of a 210MW thermal power station may range around thirty crores every month and usually about 80% of this goes towards the fuel cost. Not only fuel cost but also fuel crises increasing day to day. It is therefore, very important that one gets the best performances from the installed power plants. The first criterion of performance is the plant output. Failure in generating the maximum output from the power plant implies a default in realizing the full return from the huge capital investment made for constructing the plant. Performance degradation by 1KW from a generating unit implies a net loss of about 1.2 lacks incurred over the plant operating life. The performance criterion that receives considerable attention is the plant heat rate. An increase in heat rate by a mere 1kcal/kwh reflects into direct increase in fuel cost by about Rs.20000 per day for 210MW thermal power plant. Boiler performance, the one of the main cause of heat rate deterioration from design value as its efficiency and evaporation ratio reduces with time due to poor combustion, heat transfer fouling and poor operation and maintenance. Deterioration of fuel quality and water quality also leads to poor performance of boiler.

 OBJECTIVE

The objective of present study is as follows
 To observe the effect of different quality of coal on boiler performance as well as on unit performance.
 To study the boiler efficiency and unit heat rate by using the running parameter and investigate the various cause of performance degradation from design value.
 To study the effect of HPHs on boiler and overall unit performance.
 To study the effect of



References:

You May Also Find These Documents Helpful

  • Powerful Essays

    Chemistry of Natural Waters

    • 3362 Words
    • 21 Pages

    in boilers inefficient, and eventually corrode the metal of the pipes. Scale is considered to…

    • 3362 Words
    • 21 Pages
    Powerful Essays
  • Satisfactory Essays

    Direct to Home

    • 1307 Words
    • 6 Pages

    flange heating and gland leakage. Operation and maintenance of steam power plant, heat balance and…

    • 1307 Words
    • 6 Pages
    Satisfactory Essays
  • Powerful Essays

    Financial Analysis Report

    • 3722 Words
    • 15 Pages

    The increasing demand for utility services, particularly for electricity, is leading to the installation of large generation units. The power generators, in the wake of more stringent environmental regulations and restrictions, are gradually shifting their focus to renewable sources and natural gas to produce power. This is a welcome sign for the industry and a positive step towards reducing the emission of greenhouse gases.…

    • 3722 Words
    • 15 Pages
    Powerful Essays
  • Satisfactory Essays

    The water flow of low pressure can be adjusted,thus the tube wall temperature can adjust,when the biomass fired boiler is running in the condition of low load,the reduced value of coal consumption rate will not reduce,so it has good coal and seasonal adaptability.…

    • 245 Words
    • 1 Page
    Satisfactory Essays
  • Better Essays

    Lab 3 Marcet Boiler

    • 1157 Words
    • 5 Pages

    The water inside the boiler is heated up by the electrical resistance and starts to evaporate. As more water changes phase from liquid to vapor,…

    • 1157 Words
    • 5 Pages
    Better Essays
  • Powerful Essays

    Steam Generators and Boilers

    • 7567 Words
    • 31 Pages

    Boilers  Steam generated is employed for: (i.) Generating power in steam engines or steam turbines. (ii.) Heating the buildings in cold weather and for providing hot water supply. (iii.) In textile and chemical industries, sugar mills…

    • 7567 Words
    • 31 Pages
    Powerful Essays
  • Good Essays

    Ta Energy Case Study

    • 1790 Words
    • 8 Pages

    Long-term stable customer was a key for the success of the project. Ayhan made a contract with RG Holding to sell 19MW for 10 years. From the purchase contract of RG Holding, he could finance in total $32million from bank loans. The supply of gas and oil was also important to run the power plant. Ayhan made 20 years’ contracts with BOTAS and British Petroleum for the supply at fixed prices. For the opertation of the plant, he made an agreement with International Power Corporation for three years.…

    • 1790 Words
    • 8 Pages
    Good Essays
  • Satisfactory Essays

    High efficiency and saving energy: Using Korea vacuum hot-water boiler technology to make boiler operating in a vacuum state, Low boiling point, the latent heat of vaporization (latent heat), heat transfer, effectively improve the thermal efficiency, high heat transfer performance, the body of boiler use design of wet back with three return to effectively improve the radiation and convection heat transfer area. Thermal efficiency of boiler can be up to 91%.…

    • 343 Words
    • 2 Pages
    Satisfactory Essays
  • Powerful Essays

    In our quest to optimize the technical performance of bagasse co-generation plants, the factors influencing surplus electricity production were analyszed, using existing data. It appears that the large disparity between the electricity production of the least and the most efficient co-generation plants is not solely a matter of technological superiority, e.g., high-pressure boilers. The turbo-alternator, process steam consumption, imbibition % cane, fibre % cane, boiler efficiency, moisture % bagasse, electricity consumption in the mill and in the power plant have distinct influence on surplus electricity production.…

    • 3611 Words
    • 15 Pages
    Powerful Essays
  • Satisfactory Essays

    There is more heating surface to spare in order to assure of running of full load and overcharge.The wns series gas fired boilers have the characteristics…

    • 392 Words
    • 2 Pages
    Satisfactory Essays
  • Satisfactory Essays

    SZS series of boiler are design by double drum, longitudinal type, full water pipe structure. It is…

    • 414 Words
    • 2 Pages
    Satisfactory Essays
  • Satisfactory Essays

    ·ZG Horizontal Natural Gas Fired Steam Boiler are Low maintenance costs and High combustion efficiency…

    • 447 Words
    • 2 Pages
    Satisfactory Essays
  • Good Essays

    In the purchase process of industrial steam boiler, companies need to pay attention to the technical parameters of the model of the boiler, which is the basis of the reference that companies need to focus on. This article from the rated evaporation of industrial steam boilers (t / h), rated steam pressure (MPa), rated steam temperature (℃), water temperature (℃), applicable to analyze industrial steam boilers:…

    • 409 Words
    • 2 Pages
    Good Essays
  • Good Essays

    Coal, which is an important fundamental energy source and raw material of our country, and plays an important strategic role in the national economy, will be the main energy source in the primary energy structure of our country for a long time. From the opening and reform, the coal industry has rapidly developed, its output is on continuous increase, its production technical level is gradually enhanced, the work safety conditions of coal mines are also improved, and the coal industry has played an important role in the national economy and social development. However, there still exist many prominent problems in the development of the coal industry, such as the illogical structure, extensive growth pattern, low scientific and technological level, recurring safety accidents, serious waste of resources, retarded environmental control as well as many other problems left over by history. Along with the development of national economy, the demand on coal is on the rise, therefore the resources, environment and safety pressure will be further increased.…

    • 522 Words
    • 3 Pages
    Good Essays
  • Powerful Essays

    Doha West Power Station

    • 4276 Words
    • 18 Pages

    First of all I like to thank ministry of electricity and water in Kuwait. Also I thank Doha West Power Station where I did my training. And I thank the employees in the station specially engineering Imad Alktan who stands with as in the training.…

    • 4276 Words
    • 18 Pages
    Powerful Essays