Doppler Attack Case Study
The patient should lay on a couch and be at rest and relaxed to facilitate a true reading.
2. The patient’s left arm should be supported and with relaxed fingers. The cuff of a sphygmomanometer should be placed on the upper left arm. Using a hand held Doppler, the probe should be placed below the lower edge of the cuff, over the bifurcation of the brachial artery.
3. The cuff should be inflated beyond the expected systolic pressure in order that the pulse disappears as the artery is closed by the pressure and the blood flow stops. Listening carefully to the Doppler, the cuff should be deflated slowly. The systolic pressure occurs as the heart is at the height of its contraction, producing the highest pressure of the cycle, which is recorded
…show more content…
5. As before, inflate the cuff beyond the expected systolic pressure and then deflate slowly, listening carefully with the Doppler probe. This ankle systolic pressure reading is recorded as the first sound is heard.
6. The ABPI is calculated to be read as a ratio with the ankle reading divided by the brachial reading.
7. The systolic pressure index indicates the clinical status of the limb.
a. ABPI value of 1.3 or higher may indicate calcification of arteries;
b. ABPI between 0.9 and 1.2 would be considered normal with low risk of ulceration
c. ABPI between 0.6 and 0.9 indicate vascular disease with delayed wound healing and risk of ulceration. d. ABPI less than 0.6 indicates severe ulceration risk and low healing ability.
e. ABPI of 0.2 or below indicates critical limb ischaemia
8. ABPI readings can vary widely and generate false-positive values if there is any arterial calcification and so should be used in combination with other clinical findings (eg Buerger’s limb elevation test).
9. Patients with diabetes and sclerotic hardening of arteries should have a toe systolic

You May Also Find These Documents Helpful

  • Satisfactory Essays

    4.02 Monitoring the Heart

    • 484 Words
    • 2 Pages

    Take your pulse at the wrist, as described on the Work Out tab of 4.02, and record it below.…

    • 484 Words
    • 2 Pages
    Satisfactory Essays
  • Good Essays

    The top number 130, is the reading that is received when the heart is in contraction and blood is pushed out of the heart into the rest of the body (this is called systole). The bottom number 87, is the reading when the heart is at it relaxed state and is being refilled with blood (this is called diastole.) 2. This deposition of platelets and fibrin can cause a rapid rise in blood pressure for unknown reasons. This condition is known as acute hypertension, or a hypertensive emergency.…

    • 1090 Words
    • 5 Pages
    Good Essays
  • Satisfactory Essays

    Bc3020

    • 308 Words
    • 2 Pages

    1. Q) what position is when the patient is positioned prone and the x-ray beam comes into the patient from the right side and exits to the left?…

    • 308 Words
    • 2 Pages
    Satisfactory Essays
  • Satisfactory Essays

    EKG Practice Exercise

    • 592 Words
    • 3 Pages

    c) EKG leads are attached to the body while the patient lies flat on a bed or table.…

    • 592 Words
    • 3 Pages
    Satisfactory Essays
  • Satisfactory Essays

    2. A 76-year-old woman with a body mass index (BMI) of 17 kg/m and a low serum albumin…

    • 3421 Words
    • 17 Pages
    Satisfactory Essays
  • Good Essays

    Cardio Practice

    • 10881 Words
    • 38 Pages

    4. A client is having frequent premature ventricular contractions. The nurse should place priority on assessment of which item?…

    • 10881 Words
    • 38 Pages
    Good Essays
  • Good Essays

    A patient’s blood pressure can be affected by choosing the right equipment for the patient. Using the correct size of blood pressure cuff greatly affects the accuracy of the assessment. Apparently, one size does not fit all adult patients. Using a cuff that is relatively small to the patient’s arm will result in a falsely high BP and vice versa (Tomlinson). In situations where different cuff sizes are not available, larger size cuffs are recommended to minimize the error in measuring the BP. In applying the BP cuff, it must be put directly around the patient’s bare arm over the brachial artery and not over clothing articles to prevent putting extra pressure. In other circumstances, “if the patient’s arm is too large or too short for the proper cuff fit, the patient’s sleeve cannot be moved above the elbow, or the correct size cuff is not available, the BP can be taken on the patient’s forearm (Tomlinson).”…

    • 567 Words
    • 3 Pages
    Good Essays
  • Better Essays

    A sphygmomanometer (blood pressure cuff) and a stethoscope. The blood pressure cuff will measure systolic and diastolic blood pressure. The cuff has a pressure gauge attached to an inflatable rubber cuff that is connected by a pump . The pump is then used to inflate the rubber cuff to a pressure greater than systolic pressure . That pressure being put on the artery allows it to flatten, and stop blood flow in the artery. The stethoscope is then placed on the brachial artery in the antecubital (bend in elbow). Pressure is gradually released by opening a valve. When blood pressure is greater than the pressure in the cuff, the artery opens and blood flow returns . The person taking the blood pressure will then listen for korotkoff sounds which are caused by the turbulent flow of blood that can be heard until blood flow returns to normal. The first sound heard is the systolic pressure, and the second sound heard is the diastolic pressure. It is measure in millimeters of mercury…

    • 2572 Words
    • 11 Pages
    Better Essays
  • Satisfactory Essays

    Case Study 8 Consult

    • 599 Words
    • 3 Pages

    Patients’ base line serum creatinine is 1.5 to 1.7, patients laboratory studies from this morning indicates a BUN of 101 and a creatinine of 3.9.…

    • 599 Words
    • 3 Pages
    Satisfactory Essays
  • Good Essays

    IAH/ACS

    • 513 Words
    • 3 Pages

    For those patients with normal IAP, further measurement ought to be performed if the patient shows evidence of clinical deterioration or develops other risk factors for IAH (1).…

    • 513 Words
    • 3 Pages
    Good Essays
  • Powerful Essays

    Cardiovascular Assessment

    • 1065 Words
    • 4 Pages

    Remembering to check that the patient doesn’t have any problems with their shoulder, locate the radial pulse and place your palm over it, then raise the arm above the patient’s head. A collapsing pulse will present as a knocking on your palm.…

    • 1065 Words
    • 4 Pages
    Powerful Essays
  • Satisfactory Essays

    Mr Nunan

    • 529 Words
    • 3 Pages

    As I wanted to ensure the reading was right, as it was going into the patient notes, so I repeated the procedure three times for an accurate reading. Reflecting on this I’ve realised that at the time the patient may have felt uncomfortable due to me oinflating and deflating the cuff repeatedly…

    • 529 Words
    • 3 Pages
    Satisfactory Essays
  • Powerful Essays

    Simundic, A. (2012). Practical recommendations for statistical analysis and data presentation in Biochemia Medico journal. Biochemia Medica, 22(1), 15-23.…

    • 2371 Words
    • 10 Pages
    Powerful Essays
  • Better Essays

    ghrtgh

    • 5216 Words
    • 21 Pages

    are reasonably accurate. The relative merit of the assays used in different labs will not be…

    • 5216 Words
    • 21 Pages
    Better Essays