Aim: To determine the effect of which the temperature of the enzyme has on the rate of the enzyme catalysed reaction.
Hypothesis: The rate of reaction of an enzyme catalysed reaction will increase as the temperature of the enzyme approaches the optimum temperature. Surpassing the optimum temperature will result in a drop in enzyme activity.
Materials:
6% hydrogen peroxide
Liver suspension
10 test tubes
4 beakers
Thermometers
Measuring cylinders
Test tube pegs
Test tube rack
Bunsen burner
Tripod
Gauze mat
Ice cubes/refrigerated water
Ruler
Safety goggles
Pipettes
Method:
1. Set up equipment as follows:
Beaker
Temperature (˚C)
6% Hydrogen peroxide (mL)
Liver suspension (mL)
1

10
3
2

10
3
3

10
3
4
37
10
3
5
50
10
3

2. Fill beaker 1 with 250mL of ice cubes and tap water and record temperature.
3. Place a pair of test tubes, one of hydrogen peroxide and the other of catalase, into the cold water bath (Beaker 1) for 2 minutes.
4. Remove test tubes from the beaker simultaneously and immediately pour the catalase into the hydrogen peroxide. Measure height of froth immediately.
5. Repeat steps 2-4 with beaker 2 and tap water.
6. Repeat steps 3 and 4 with beaker 3 with no water, record room temperature.
7. Repeat steps 2-4 with beaker 4 and heated water of 37˚C.
8. Repeat steps 2-4 with beaker 5 and heated water of 50˚C.
Risk assessment:
As hydrogen peroxide is an irritant, wear safety goggles to protect eyes from possible splashes and clean up any spillages quickly.
Equipment will be hot and may cause burns. Handle equipment with caution and use test tube pegs when dealing with hot test tubes.
Results:
Beaker
Temperature (˚C)
Reaction rate – Froth height (mm)
1

2

3

4

5

You May Also Find These Documents Helpful

  • Good Essays

    Week 4 iLab Report

    • 640 Words
    • 4 Pages

    7) Trial C: Remove the syringe by selecting the Combined equipment and then selecting Remove from under the Arrange menu. Empty the beaker by clicking on it and then selecting Empty from the right-mouse button context menu. Add a Thermometer to the beaker. Add 100 mL of Ice Water and then add another 100 mL of Room Temperature water by selecting Volume level 200.0 mL in the Distilled Water dialog box. Repeat Steps 5 & 6.…

    • 640 Words
    • 4 Pages
    Good Essays
  • Good Essays

    Formal Lab Report 2 Final

    • 1572 Words
    • 7 Pages

    1. Place 2 ml of the 3% hydrogen peroxide solution into a clean test tube…

    • 1572 Words
    • 7 Pages
    Good Essays
  • Good Essays

    Making Salt Lab

    • 384 Words
    • 2 Pages

    6. Place the test tube in a beaker with water. It will start to boil. Continue letting it boil until all liquid is evaporated out of the test tube.…

    • 384 Words
    • 2 Pages
    Good Essays
  • Good Essays

    Glow Stick Lab

    • 702 Words
    • 3 Pages

    2. Take Beaker 1 and fill it ¾ full with refrigerated water (12 degrees Celsius).…

    • 702 Words
    • 3 Pages
    Good Essays
  • Good Essays

    Easy Peasy

    • 401 Words
    • 2 Pages

    4. Different concentrations of hydrogen peroxide solution were added to each test tube using a pipette. (5mL of 6%, 3% and 1.5%)…

    • 401 Words
    • 2 Pages
    Good Essays
  • Good Essays

    4. Place 2 test tubes in each of the Beakers – one to receive the enzyme and one as a control. A thermometer was placed in each test tube.…

    • 929 Words
    • 4 Pages
    Good Essays
  • Good Essays

    Catalase Lab Report

    • 563 Words
    • 3 Pages

    Next, 50ml of distilled water will be measured using a graduated cylinder. The 50g of catalase and the 50ml of distilled water will be put into a blender and blended until liquefied. The catalase solution will then be introduced to a Buchner funnel filtration system to separate the catalase extract from any solid particles left over from the blending process. This step will be repeated until all of the catalases have been blended and filtered. Next, 5 ml of hydrogen peroxide will be measured out using a graduated cylinder. It will then be poured into a small Erlenmeyer flask. This will be repeated five times, representing the five trials for each catalase treatment. Once the Erlenmeyer flask has been given 5ml of hydrogen peroxide, 10ml of the S. oleracea catalase will be measured out and poured into the Hydrogen peroxide filled flask. When the catalase and Hydrogen peroxide meet a reaction will occur and the hydrogen peroxide will be broken down into water and oxygen. The oxygen released from the reaction will be recorded by the Gas Pressure sensor. This step will be repeated five times for each necessary trial, then the next catalase extract will be…

    • 563 Words
    • 3 Pages
    Good Essays
  • Good Essays

    4. Add another 30 mL of hot water while stirring. Measure and record the temperature.…

    • 1576 Words
    • 7 Pages
    Good Essays
  • Good Essays

    The prediction for the effects of temperature on the enzyme activity was that the reaction’s rate would increase as the temperature increased, until they go over the optimum temperature where the enzymes denature and the reaction’s rate quickly drops to zero. At 5 degree C the rate is 0.00059mole PNP/min. This then increases to 0.01031mmoles PNP/min at a temperature of 50 degree C. The rate then drops drastically to -0.00215moles PNP/min. This point is where the enzymes have been denatured and have no activity, shown as the last point on the fig 8 and 9, do not fit on the graph. The optimum temperature was about 47 degree C. The core body temperature is only about 37 degree C and thus these enzymes are operating below their optimum temperature.…

    • 521 Words
    • 3 Pages
    Good Essays
  • Satisfactory Essays

    Chem Answers

    • 400 Words
    • 2 Pages

    If you are heating liquid in a test tube to a temperature less than 100 degrees. You should use a test tube holder, clamp and hot water.…

    • 400 Words
    • 2 Pages
    Satisfactory Essays
  • Good Essays

    Lab 6 enzymes

    • 1000 Words
    • 5 Pages

    Preparation Step 1: Research (online) the reaction between catalase and hydrogen peroxide and be familiar with the reactants, products, and enzyme. You will include the overall reaction in your lab report for this experiment. We will measure enzyme activity by measuring the height of the bubbles produced.…

    • 1000 Words
    • 5 Pages
    Good Essays
  • Good Essays

    Enzyme Catalysis Lab

    • 759 Words
    • 4 Pages

    That change in temperature, pH, enzyme concentration, and substrate concentration can affect the initial reaction rates of enzyme-catalyzed reactions; and…

    • 759 Words
    • 4 Pages
    Good Essays
  • Good Essays

    Biology Enzyme Practical

    • 565 Words
    • 3 Pages

    Safety risks – by doing this experiment there might be some risks if the equipment is not used properly. The tubes or anything that with glass must not be at the edge of the table, because it can fall down, and someone can cut themselves. The person that is carrying out the experiment must wear the safety goggles. Hydrogen peroxide is not dangerous, but it is an irritant, so the person must protect their eyes. Also the lab coat must be worn to avoid any splashes, in order to protect clothes or skin.…

    • 565 Words
    • 3 Pages
    Good Essays
  • Satisfactory Essays

    The rate of an enzyme-catalyzed reaction increases as the temperature is raised. If the temperature is too high, the enzyme will start to…

    • 179 Words
    • 1 Page
    Satisfactory Essays
  • Good Essays

    3. The beaker is immersed into a container with ice and water to cool down the temperature.…

    • 1183 Words
    • 5 Pages
    Good Essays