Preview

BG4201393395

Powerful Essays
Open Document
Open Document
1590 Words
Grammar
Grammar
Plagiarism
Plagiarism
Writing
Writing
Score
Score
BG4201393395
Mr.A Kumar Tiwari et al Int. Journal of Engineering Research and Applications
ISSN : 2248-9622, Vol. 4, Issue 2( Version 1), February 2014, pp.393-395

RESEARCH ARTICLE

www.ijera.com

OPEN ACCESS

Automatic Power Factor Correction Using Capacitive Bank
Mr.Anant Kumar Tiwari, Mrs. Durga Sharma, Mr.Vijay Kumar Sharma
Dr. C.V. Raman Institute of Science and Technology Bilaspur.
Assistant professor Dr. C.V. Raman Institute of Science and Technology, Bilaspur.
Assistant professor Lkct Indore (M.P.)

ABSTRACT
The power factor correction of electrical loads is a problem common to all industrial companies. Earlier the power factor correction was done by adjusting the capacitive bank manually [1]. The automated power factor corrector (APFC) using capacitive load bank is helpful in providing the power factor correction. Proposed automated project involves measuring the power factor value from the load using microcontroller.
The design of this auto-adjustable power factor correction is to ensure the entire power system always preserving unity power factor. The software and hardware required to implement the suggested automatic power factor correction scheme are explained and its operation is described. APFC thus helps us to decrease the time taken to correct the power factor which helps to increase the efficiency.
Keywords
APFC,
Apparent
power,
Capacitor
bank,
Power
factor

I. INTRODUCTION
Majority of the loads in the industries are highly inductive in nature such as induction motors,
AC/DC drives, welding machines, arc furnaces, fluorescent Lightings, electronic controls and computers. There may be a few resistive loads for heaters and incandescent bulbs. Very rarely industries may have capacitive loads such as synchronous motors [2].
Net industrial load is highly inductive causing a very poor lagging power factor. If this poor power factor is left uncorrected, the industry will require a high maximum demand from Electricity Board and also will suffer a penalty for poor



References: Keith Harker (1998). “Power System Commissioning and Maintenance practice.” Stephen, J. C. (1999). “Electric Machinery and Power System Fundamentals.” 3rd.ed. Barsoum, Nader (2007) “Programming of PIC Micro-Controller for Power Factor Rakendu Mandal; Sanjoy Kumar Basu; Asim Kar; Shyama Pada Chowdhury (1994) Jos Arrillaga, Neville R. Watson (2003). Ramasamy Natarajan (2005). “Power System Capacitors.” Boca Raton, FL: Taylor

You May Also Find These Documents Helpful

  • Satisfactory Essays

    The electrodynamic wattmeter is used to measure (Useful) power taken from ac power supplies. The electrodynamic wattmeter uses the reaction between the magnetic fields of two current-carrying coils, one fixed and the other movable. The voltage and current coils are wound around a laminated iron core to produce a magnetic field across the air gap. When the current through the fixed-position field windings is the same as current through the load and the current through the moving coil is proportional to the load voltage, then the pointer deflection is proportional to the power (P=IV).…

    • 445 Words
    • 2 Pages
    Satisfactory Essays
  • Good Essays

    Power factor (Pf) is the ratio of real power (kW) to the apparent power (kVA). Power factor decreases with the installation of non-resistive loads, such as motors, transformers, lighting ballasts and other power electronics.…

    • 391 Words
    • 2 Pages
    Good Essays
  • Satisfactory Essays

    Within this experiment we recorded that the theoretical capacitance of 0.470 is accurate with the capacitor from box C. The LRC circuit is proven to have a voltage accurate with the measured generator voltage because the largest percentage of error , 0.55 % error, is much lower than 5% error.…

    • 260 Words
    • 2 Pages
    Satisfactory Essays
  • Better Essays

    Muhammad H. Rashid., Power Electronics Circuits, Devices, and Applications 3rd edition, Pearson Prentice Hall, 2004.…

    • 1501 Words
    • 7 Pages
    Better Essays
  • Good Essays

    Disadvantages of FCs. From the electrical point of view, as a result of aging the FC internal impedance slowly increases, therefore, we need a power electronic interface to regulate the output voltage.…

    • 1133 Words
    • 5 Pages
    Good Essays
  • Good Essays

    Keywords—Voltage Flicker, Harmonic Power, EAF. I. INTRODUCTION OLTAGE flicker is mainly caused by rapid change of loads in power systems, such as electric arc furnaces (EAF). During the operation of an EAF, the electric poles short circuit and an enormously unstable current is produced, causing current flow to change significantly, and in turn causing serious voltage flickers that influences neighboring power consumers. According to IEEE Std-100 [1], voltage flicker is luminosity variation or an image disruption caused by lower frequency voltage fluctuations. Power systems currently face serious problems arising from voltage flicker, which is an important threat to power quality [2], and is currently being targeted by the aggressive power supply quality improvement efforts of the Taiwan Power Company (TPC). Presently, the major source of flicker is the EAF used in steel making plants. Voltage flicker associated with an EAF is evaluated in two main ways around the world. The first is flicker meter, which is the IEC standard and has been…

    • 4020 Words
    • 17 Pages
    Good Essays
  • Better Essays

    The APF technology is now mature for providing compensation for harmonics, reactive power, and/or neutral current in ac networks. It has evolved in the past quarter century of development with varying configurations, control strategies, and solid-state devices. APF’s are also used to eliminate voltage harmonics, to regulate terminal voltage, to suppress voltage flicker, and to improve voltage balance in three-phase…

    • 1648 Words
    • 7 Pages
    Better Essays
  • Powerful Essays

    upqc

    • 5337 Words
    • 22 Pages

    Keywords : power quality (PQ), harmonics, voltage sag, voltage swell, active power filter (apf), unified…

    • 5337 Words
    • 22 Pages
    Powerful Essays
  • Better Essays

    I would like to offer my sincere gratitude to Professor Gargi Konar, who has contributed to this project in a major way. I thank her for her guidance and support during the project with her immense expertise and cooperation on the topic.…

    • 2291 Words
    • 10 Pages
    Better Essays
  • Good Essays

    Power Supply

    • 1155 Words
    • 5 Pages

    Aimed at system designers whose interest focusses on other fields, this note reviews the basic power supply design knowhow assumed in the rest of the book.…

    • 1155 Words
    • 5 Pages
    Good Essays
  • Best Essays

    powerful computer based software. This research work highlights the effective use of Electrical Transient Analyzer Program…

    • 2373 Words
    • 10 Pages
    Best Essays
  • Good Essays

    FACTS Devices

    • 683 Words
    • 3 Pages

    This method is used to improve the power factor. Whenever an inductive load is connected to the transmission line, power factor lags because of lagging load current. To compensate, a shunt capacitor is connected which draws current leading the source voltage. The net result is improvement in power factor.…

    • 683 Words
    • 3 Pages
    Good Essays
  • Powerful Essays

    Dc Power Supply

    • 2327 Words
    • 10 Pages

    Abstract : A DC power supply is very important in our day to day life. We use it to charge or operate our DC components like charger light, cell phone battery charger etc. It’s nothing but a AC to DC converter.…

    • 2327 Words
    • 10 Pages
    Powerful Essays
  • Satisfactory Essays

    Welcome Speech

    • 1700 Words
    • 7 Pages

    It is an electronics unit, which is used to give regulated power to any electronics system.…

    • 1700 Words
    • 7 Pages
    Satisfactory Essays
  • Good Essays

    Uninterrupted Power Supply

    • 15376 Words
    • 62 Pages

    This is to certify that project report entitled “UPS” for Government Polytechnic College, Amritsar submitted by Simranjeet Singh, Avneet Kaur, Ruhi Devgan, Kulwinder Kaur, Meenu Bala. Computer Engineering Final year (2008-2011) of Government Polytechnic College, Amritsar is a bonafide and authentic piece of work carried by them under the guidance and supervision of college authorities. The quality of work fulfills the entire necessary requirement relating to the said degree.…

    • 15376 Words
    • 62 Pages
    Good Essays

Related Topics